Eaton
C440C1A140SAX
C440 OL (28-140A) STANDALONE STD FLT
$604.74$722.09 -
Eaton
C440C1A140SF4
C440 OL (28-140A) FRDM SZ 4 STD FLT
$719.25$858.82 -
Eaton
C440C1A140SF4C
C440 OL (28-140A) FRDM SZ 4 COMPACT STD FLT
$664.29$793.18 -
Eaton
C440C2A140SAX
C440 OL (28-140A) STANDALONE GRND FLT
$768.14$917.18 -
Eaton
C440C2A140SF4
C440 OL (28-140A) FRDM SZ 4 GRND FLT
$882.68$1,053.93 -
Eaton
C440C2A140SF4C
C440 OL (28-140A) FRDM SZ 4 COMPACT GRND FLT
$826.15$986.46 -
ABB
CCL5-11
A Aux Blk,1No Lead,1Nc Lag
$28.36$65.35 -
Weg
CSW30-RSBW
External Reset Button
$15.47$22.00 -
ABB
DB140E
E140Du Separate Mounting Kit
$50.03$91.65 -
ABB
DB16-ABB
Db16 Single Mounting Kit
$28.64$39.21 -
ABB
DB16E
Sep Mtg Adapter For E16Du
$14.31$19.60 -
ABB
DB200
Sep Mtg Kit,Ta110,Less Lugs
$57.28$78.42 -
ABB
DB200A
Sep Mtg Kit,Ta110,W/Lugs
$85.10$196.07 -
ABB
DB25/25A
Mounting Kit Ta25Du 0 1-25A
$31.26$65.35 -
ABB
DB25/25ART
Mounting Base For Overload Relay
$86.48$93.32 -
ABB
DB25/32A
Separate Mounting Kit-
$36.29$49.68 -
ABB
DB42
Tf42 Panel Mount Kit
$33.41$45.75 -
ABB
DB45E
E45Du Separate Mounting Kit
$29.54$49.98 -
ABB
DB45EF
Ef45 Single Mounting Kit
$57.28$78.42 -
ABB
DB65
Separate Mtg Kit Tf65
$31.50$43.12 -
ABB
DB80
Separate Mtg Kit-Ta42,75,80
$42.96$58.82 -
ABB
DB80E
E80Du Separate Mounting Kit
$34.30$109.98 -
ABB
DB96
Separate Mtg Kit Ef96
$60.14$82.34 -
ABB
DR25-A-110
Remote Resetting Coil,110V
$45.44$98.32 -
ABB
DR25-A-220/380
Remote Resetting Coil,220/380V
$57.28$78.42 -
ABB
DR25-A-24
Remote Resetting Coil,24V
$57.28$78.42 -
ABB
DR25-A-500
Remote Resetting Coil,500V
$62.53$130.70 -
ABB
DRS-F-EF-01
Remote Stop Coil 24-30 V
$47.49$65.02
Thermal and Electronic Overload Relays
What Is an Overload Relay?
An overload relay is a motor protection device that monitors the current drawn by a motor and disconnects it when that current stays above a set level for long enough to cause damage. It protects against sustained overload, phase loss, and current imbalance, all of which cause a motor to overheat. An overload relay does not provide short-circuit protection, which is handled separately by fuses or a circuit breaker.
Protect your motors from overcurrent and overheating with Eaton, ABB, WEG and Noark overload relays. Available in thermal and electronic options, our relays provide reliable motor protection for a variety of applications, including pumps, conveyors, and HVAC systems. Ensure your operations run smoothly and safely with the right motor protection solution from Wistex.
Overload Relays We Offer
Wistex offers a full range of overload relays designed to protect motors from overheating, phase loss, and excessive current. Whether you need thermal or electronic protection, we provide reliable solutions for industrial applications across manufacturing, pumping, and HVAC systems.
Thermal Overload Relays
Thermal overload relays use a bimetallic strip that reacts to heat generated by excess current. As the strip bends, it pushes a mechanical trip bar that changes the state of the relay’s internal contacts, opening the control circuit and dropping out the contactor that feeds the motor.
Electronic Overload Relays
Electronic overload relays use digital sensors to detect current surges with greater precision and speed. They offer adjustable settings, diagnostics, and advanced features like phase failure detection. Electronic relays are well-suited for applications requiring flexible, programmable motor protection and integration with control systems.
Trip class defines how long a relay will carry six times its rated current before tripping. Class 10 trips within ten seconds and suits standard motors; Class 20 within twenty seconds where starting takes longer; and Class 30 within thirty seconds for high-inertia loads such as large fans. Electronic relays use the equivalent 10E, 20E, and 30E designations.
Because sensing does not depend on a heated metal strip, electronic relays are less prone to false trips when the ambient temperature inside the enclosure changes.
Parts of a Thermal Overload Relay
A thermal overload relay has a current adjustment dial set to the motor’s full-load amperage. Its normally closed contacts, numbered 95 and 96, wire in series with the contactor coil, so a trip drops out the contactor. The normally open contacts, 97 and 98, signal an alarm or indicator light. A separate selector sets manual or automatic reset once the bimetallic strip cools.
Why Does an Overload Relay Keep Tripping?
Repeated tripping usually indicates a condition in the motor or the driven load rather than a faulty relay. The most common causes are a mechanical jam or increased load, a current dial set below the motor’s full-load amperage, phase loss or voltage imbalance on the supply, high ambient temperature inside the enclosure, and a trip class too short for the motor’s acceleration time.
Applications for Overload Relays
Our overload relays are ideal for:
- Motor protection for water pumps and industrial fans
- Conveyor belt systems in manufacturing
- HVAC system compressors and blower motors
Complete your motor control system with contactors and soft starters.
Why Choose Wistex for Overload Relays & Motor Protection
Protect your investments with overload relays from Wistex. Our selection of thermal and electronic overload relays from ABB provides vital protection against overcurrent, phase failure, and overheating — essential for industries like manufacturing, pumping, and HVAC.
Why choose Wistex for overload relays?
- Specialized expertise in motor protection and system design
- In-stock options for fast shipping when downtime isn’t an option
- Top brands like ABB for unmatched reliability
- Support beyond the sale — helping you with setup, replacement, and scaling needs
Keep your motors safe and your business moving forward with overload relays from Wistex.
FAQs about Overload Relays
Understand how overload relays protect your motors and improve operational reliability.
Overload relays detect excessive current flowing through a motor circuit. If the current exceeds a preset level for too long (indicating a jam, blockage, or overload), the relay trips to disconnect the motor, preventing overheating and mechanical damage.
Thermal overload relays use a mechanical bimetallic strip that bends when heated by excess current. Electronic overload relays use sensors and processors for faster, more precise detection of overload conditions, often with more flexible setting options.
Replace an overload relay if it trips frequently without valid cause, shows inconsistent operation, suffers visible damage, or if the protected motor has been upgraded to a higher horsepower. Routine inspection during maintenance can help catch early signs of failure.