Thermal and Electronic Overload Relays

What Is an Overload Relay?

An overload relay is a motor protection device that monitors the current drawn by a motor and disconnects it when that current stays above a set level for long enough to cause damage. It protects against sustained overload, phase loss, and current imbalance, all of which cause a motor to overheat. An overload relay does not provide short-circuit protection, which is handled separately by fuses or a circuit breaker.

Protect your motors from overcurrent and overheating with Eaton, ABB, WEG and Noark overload relays. Available in thermal and electronic options, our relays provide reliable motor protection for a variety of applications, including pumps, conveyors, and HVAC systems. Ensure your operations run smoothly and safely with the right motor protection solution from Wistex.

  • BFD75S | Eaton 7NO-5NC 120VDC COIL
    Eaton

    BFD75S

    7NO-5NC 120VDC COIL

    $1,225.88
    $1,463.73
  • BFD75T | Eaton 7NO-5NC 240VDC COIL
    Eaton

    BFD75T

    7NO-5NC 240VDC COIL

    $1,225.88
    $1,463.73
  • BFD80E | Eaton BFD RELAY 8NO W/72V DC COIL
    Eaton

    BFD80E

    BFD RELAY 8NO W/72V DC COIL

    $952.20
    $1,136.96
  • BFD80L | Eaton BFD RELAY 8NO-0NC, 24VDC COIL
    Eaton

    BFD80L

    BFD RELAY 8NO-0NC, 24VDC COIL

    $952.20
    $1,136.96
  • BFD80M | Eaton BFD RELAY 8NO-0NC, 48VDC COIL
    Eaton

    BFD80M

    BFD RELAY 8NO-0NC, 48VDC COIL

    $952.20
    $1,136.96
  • BFD80S | Eaton BFD80S RELAY A
    Eaton

    BFD80S

    BFD80S RELAY A

    $952.20
    $1,136.96
  • BFD82L | Eaton RELAY 8N0-2NC 24VDC COIL
    Eaton

    BFD82L

    RELAY 8N0-2NC 24VDC COIL

    $1,020.94
    $1,219.02
  • BFD82T | Eaton 8NO-2NC 240VDC COIL
    Eaton

    BFD82T

    8NO-2NC 240VDC COIL

    $1,083.40
    $1,293.61
  • BFD84L | Eaton TYPE BFD RELAY WITH 24VDC COIL 8NO-4NC
    Eaton

    BFD84L

    TYPE BFD RELAY WITH 24VDC COIL 8NO-4NC

    $1,083.40
    $1,293.61
  • BFD84S | Eaton BFD 84S RELAY A
    Eaton

    BFD84S

    BFD 84S RELAY A

    $1,083.40
    $1,293.61
  • BFD84T | Eaton 8NO-4NC 240VDC COIL
    Eaton

    BFD84T

    8NO-4NC 240VDC COIL

    $1,083.40
    $1,293.61
  • BFDA11S | Eaton BFD Relay With Overlapping Contacts
    Eaton

    BFDA11S

    BFD Relay With Overlapping Contacts

    $672.88
    $803.45
  • BFDA20S | Eaton BFD Relay With Overlapping Contacts
    Eaton

    BFDA20S

    BFD Relay With Overlapping Contacts

    $634.10
  • BFDF20M | Eaton 2NO-0NC 48VDC COIL
    Eaton

    BFDF20M

    2NO-0NC 48VDC COIL

    $626.34
    $747.86
  • BFDF22D | Eaton BFDF 22D
    Eaton

    BFDF22D

    BFDF 22D

    $719.43
    $859.02
  • BFDF22L | Eaton TYPE BFD RELAY 2NO-2NC WITH 24VDC COIL & FAST-ON TERM
    Eaton

    BFDF22L

    TYPE BFD RELAY 2NO-2NC WITH 24VDC COIL & FAST-ON TERM

    $630.60
    $752.95
  • BFDF22S | Eaton 4P BFD RELAY. 2 NO 2 NC CARTRIDGE. FASTON PUSH TERM. 120 VDC
    Eaton

    BFDF22S

    4P BFD RELAY. 2 NO 2 NC CARTRIDGE. FASTON PUSH TERM. 120 VDC

    $719.43
    $859.02
  • BFDF22T | Eaton 2NO-2NC W/FASTON
    Eaton

    BFDF22T

    2NO-2NC W/FASTON

    $719.43
    $859.02
  • BFDF31L | Eaton BFD RELAY 4P WITH 24VDC COIL AND FAST-ON TERM
    Eaton

    BFDF31L

    BFD RELAY 4P WITH 24VDC COIL AND FAST-ON TERM

    $784.33
    $936.50
  • BFDF31S | Eaton 3NO-1NC W/FASTON
    Eaton

    BFDF31S

    3NO-1NC W/FASTON

    $777.28
    $928.09
  • BFDF31T | Eaton BFDF31T RELAY A
    Eaton

    BFDF31T

    BFDF31T RELAY A

    $770.21
    $919.66
  • BFDF44S | Eaton TYPE BFD RELAY 4NO-4NC WITH 120VDC COIL & FAST-ON TERM.
    Eaton

    BFDF44S

    TYPE BFD RELAY 4NO-4NC WITH 120VDC COIL & FAST-ON TERM.

    $885.90
    $1,057.79
  • BFDF44T | Eaton BFDF44T RELAY A
    Eaton

    BFDF44T

    BFDF44T RELAY A

    $870.38
    $1,039.26
  • BFDF62T | Eaton BFDF62T RELAY A
    Eaton

    BFDF62T

    BFDF62T RELAY A

    $994.53
    $1,187.50
  • BFDF80T | Eaton 8NO-8NC W/FASTON
    Eaton

    BFDF80T

    8NO-8NC W/FASTON

    $1,022.73
    $1,221.17
  • BFDL66M | Eaton BFD RELAY 48VDC COIL, 12 POLE, 6 NO 6 NC
    Eaton

    BFDL66M

    BFD RELAY 48VDC COIL, 12 POLE, 6 NO 6 NC

    $1,406.44
    $1,679.33
  • BFDW20 | Eaton BF Relay W/ Modified Kickout Spring 10A, 4P
    Eaton

    BFDW20

    BF Relay W/ Modified Kickout Spring 10A, 4P

    $575.61
  • BFF11F | Eaton 1NO-1NC W/FASTON
    Eaton

    BFF11F

    1NO-1NC W/FASTON

    $466.93
    $557.53

Overload Relays We Offer

Wistex offers a full range of overload relays designed to protect motors from overheating, phase loss, and excessive current. Whether you need thermal or electronic protection, we provide reliable solutions for industrial applications across manufacturing, pumping, and HVAC systems.

Thermal Overload Relays

Thermal overload relays use a bimetallic strip that reacts to heat generated by excess current. As the strip bends, it pushes a mechanical trip bar that changes the state of the relay’s internal contacts, opening the control circuit and dropping out the contactor that feeds the motor.

Electronic Overload Relays

Electronic overload relays use digital sensors to detect current surges with greater precision and speed. They offer adjustable settings, diagnostics, and advanced features like phase failure detection. Electronic relays are well-suited for applications requiring flexible, programmable motor protection and integration with control systems.

Trip class defines how long a relay will carry six times its rated current before tripping. Class 10 trips within ten seconds and suits standard motors; Class 20 within twenty seconds where starting takes longer; and Class 30 within thirty seconds for high-inertia loads such as large fans. Electronic relays use the equivalent 10E, 20E, and 30E designations.

Because sensing does not depend on a heated metal strip, electronic relays are less prone to false trips when the ambient temperature inside the enclosure changes.

Parts of a Thermal Overload Relay

A thermal overload relay has a current adjustment dial set to the motor’s full-load amperage. Its normally closed contacts, numbered 95 and 96, wire in series with the contactor coil, so a trip drops out the contactor. The normally open contacts, 97 and 98, signal an alarm or indicator light. A separate selector sets manual or automatic reset once the bimetallic strip cools.

Why Does an Overload Relay Keep Tripping?

Repeated tripping usually indicates a condition in the motor or the driven load rather than a faulty relay. The most common causes are a mechanical jam or increased load, a current dial set below the motor’s full-load amperage, phase loss or voltage imbalance on the supply, high ambient temperature inside the enclosure, and a trip class too short for the motor’s acceleration time.

Applications for Overload Relays

Our overload relays are ideal for:

  • Motor protection for water pumps and industrial fans
  • Conveyor belt systems in manufacturing
  • HVAC system compressors and blower motors

Complete your motor control system with contactors and soft starters.

Why Choose Wistex for Overload Relays & Motor Protection

Protect your investments with overload relays from Wistex. Our selection of thermal and electronic overload relays from ABB provides vital protection against overcurrent, phase failure, and overheating — essential for industries like manufacturing, pumping, and HVAC.

Why choose Wistex for overload relays?

  • Specialized expertise in motor protection and system design
  • In-stock options for fast shipping when downtime isn’t an option
  • Top brands like ABB for unmatched reliability
  • Support beyond the sale — helping you with setup, replacement, and scaling needs

Keep your motors safe and your business moving forward with overload relays from Wistex.

FAQs about Overload Relays

Understand how overload relays protect your motors and improve operational reliability.

Overload relays detect excessive current flowing through a motor circuit. If the current exceeds a preset level for too long (indicating a jam, blockage, or overload), the relay trips to disconnect the motor, preventing overheating and mechanical damage.

Thermal overload relays use a mechanical bimetallic strip that bends when heated by excess current. Electronic overload relays use sensors and processors for faster, more precise detection of overload conditions, often with more flexible setting options.

Replace an overload relay if it trips frequently without valid cause, shows inconsistent operation, suffers visible damage, or if the protected motor has been upgraded to a higher horsepower. Routine inspection during maintenance can help catch early signs of failure.