Thermal and Electronic Overload Relays

What Is an Overload Relay?

An overload relay is a motor protection device that monitors the current drawn by a motor and disconnects it when that current stays above a set level for long enough to cause damage. It protects against sustained overload, phase loss, and current imbalance, all of which cause a motor to overheat. An overload relay does not provide short-circuit protection, which is handled separately by fuses or a circuit breaker.

Protect your motors from overcurrent and overheating with Eaton, ABB, WEG and Noark overload relays. Available in thermal and electronic options, our relays provide reliable motor protection for a variety of applications, including pumps, conveyors, and HVAC systems. Ensure your operations run smoothly and safely with the right motor protection solution from Wistex.

  • BFF11G | Eaton BFF RELAY
    Eaton

    BFF11G

    BFF RELAY

    $344.21
    $411.00
  • BFF13F | Eaton 1NO-3NC 120V W/FSTN
    Eaton

    BFF13F

    1NO-3NC 120V W/FSTN

    $610.84
    $729.36
  • BFF20F | Eaton BFF20F RELAY A
    Eaton

    BFF20F

    BFF20F RELAY A

    $447.18
    $533.95
  • BFF20G | Eaton 2NO-0NC W/FASTON
    Eaton

    BFF20G

    2NO-0NC W/FASTON

    $466.93
    $557.53
  • BFF22F | Eaton BFF22F RELAY A
    Eaton

    BFF22F

    BFF22F RELAY A

    $533.25
    $636.71
  • BFF22G | Eaton BFF RELAY 2NO-2NC, 220/240V 50/60HZ COIL
    Eaton

    BFF22G

    BFF RELAY 2NO-2NC, 220/240V 50/60HZ COIL

    $533.25
    $636.71
  • BFF30F | Eaton 3NO-0NC 120V W/FSTN
    Eaton

    BFF30F

    3NO-0NC 120V W/FSTN

    $533.25
    $636.71
  • BFF31F | Eaton BFF31F RELAY A
    Eaton

    BFF31F

    BFF31F RELAY A

    $603.78
    $720.92
  • BFF33F | Eaton 2NO-3NC W/FASTON
    Eaton

    BFF33F

    2NO-3NC W/FASTON

    $626.34
    $747.86
  • BFF40F | Eaton BFF 4NO-0NC
    Eaton

    BFF40F

    BFF 4NO-0NC

    $610.84
    $729.36
  • BFF42F | Eaton 4NO-2NC W/FASTON
    Eaton

    BFF42F

    4NO-2NC W/FASTON

    $703.91
    $840.50
  • BFF44F | Eaton BFF 44F RELAY A
    Eaton

    BFF44F

    BFF 44F RELAY A

    $689.83
    $823.66
  • BFF44G | Eaton 4NO-4NC W/FASTON
    Eaton

    BFF44G

    4NO-4NC W/FASTON

    $719.43
    $859.02
  • BFF53F | Eaton 5NO-3NC 110/120V
    Eaton

    BFF53F

    5NO-3NC 110/120V

    $861.90
    $1,029.14
  • BFF55F | Eaton 5NO-5NC 120V W/FSTN
    Eaton

    BFF55F

    5NO-5NC 120V W/FSTN

    $873.19
    $1,042.62
  • BFF62F | Eaton BFF62F RELAY A
    Eaton

    BFF62F

    BFF62F RELAY A

    $825.25
    $985.37
  • BFF62G | Eaton 6NO-2NC W/FASTON
    Eaton

    BFF62G

    6NO-2NC W/FASTON

    $861.90
    $1,029.14
  • BFF66F | Eaton 6NO-6NC 120V W/FSTN
    Eaton

    BFF66F

    6NO-6NC 120V W/FSTN

    $1,022.73
    $1,221.17
  • BFF80F | Eaton BFF80F RELAY A
    Eaton

    BFF80F

    BFF80F RELAY A

    $825.25
    $985.37
  • BFF84F | Eaton BFF 8NO-4NC
    Eaton

    BFF84F

    BFF 8NO-4NC

    $1,022.73
    $1,221.17
  • BFF84G | Eaton 8NO-4NC 240V W/FSTN
    Eaton

    BFF84G

    8NO-4NC 240V W/FSTN

    $1,022.73
    $1,221.17
  • BFFA62F | Eaton BF RELAY 8 POLE AC OVERL
    Eaton

    BFFA62F

    BF RELAY 8 POLE AC OVERL

    $1,189.20
    $1,419.95
  • BFMLF | Eaton PERM MAG LATCH FOR BF RELAY 110/50 120/60V
    Eaton

    BFMLF

    PERM MAG LATCH FOR BF RELAY 110/50 120/60V

    $399.51
    $477.02
  • BFMLL | Eaton BFMLL LATCH MAG PRM
    Eaton

    BFMLL

    BFMLL LATCH MAG PRM

    $610.84
    $729.36
  • BFW20G | Eaton BF RELAY W/ MODIFIED KICKOUT SPRING 10A, 4P
    Eaton

    BFW20G

    BF RELAY W/ MODIFIED KICKOUT SPRING 10A, 4P

    $300.46
    $358.76
  • C440A1A005SAX-84 | Eaton C440 OL (1-5A) NEMA STAND ALONE STANDARD (BLK PK)
    Eaton

    C440A1A005SAX-84

    C440 OL (1-5A) NEMA STAND ALONE STANDARD (BLK PK)

    $247.40
    $295.41
  • C440A1A005SDD | Eaton C440 DP OL (1-5A) 50MM - STANDARD
    Eaton

    C440A1A005SDD

    C440 DP OL (1-5A) 50MM - STANDARD

    $290.81
    $310.21
  • C440A1A005SF0-84 | Eaton C440 OL (1-5A) FRDM SZ 0 STANDARD (BLK PK)
    Eaton

    C440A1A005SF0-84

    C440 OL (1-5A) FRDM SZ 0 STANDARD (BLK PK)

    $229.09
    $273.53

Overload Relays We Offer

Wistex offers a full range of overload relays designed to protect motors from overheating, phase loss, and excessive current. Whether you need thermal or electronic protection, we provide reliable solutions for industrial applications across manufacturing, pumping, and HVAC systems.

Thermal Overload Relays

Thermal overload relays use a bimetallic strip that reacts to heat generated by excess current. As the strip bends, it pushes a mechanical trip bar that changes the state of the relay’s internal contacts, opening the control circuit and dropping out the contactor that feeds the motor.

Electronic Overload Relays

Electronic overload relays use digital sensors to detect current surges with greater precision and speed. They offer adjustable settings, diagnostics, and advanced features like phase failure detection. Electronic relays are well-suited for applications requiring flexible, programmable motor protection and integration with control systems.

Trip class defines how long a relay will carry six times its rated current before tripping. Class 10 trips within ten seconds and suits standard motors; Class 20 within twenty seconds where starting takes longer; and Class 30 within thirty seconds for high-inertia loads such as large fans. Electronic relays use the equivalent 10E, 20E, and 30E designations.

Because sensing does not depend on a heated metal strip, electronic relays are less prone to false trips when the ambient temperature inside the enclosure changes.

Parts of a Thermal Overload Relay

A thermal overload relay has a current adjustment dial set to the motor’s full-load amperage. Its normally closed contacts, numbered 95 and 96, wire in series with the contactor coil, so a trip drops out the contactor. The normally open contacts, 97 and 98, signal an alarm or indicator light. A separate selector sets manual or automatic reset once the bimetallic strip cools.

Why Does an Overload Relay Keep Tripping?

Repeated tripping usually indicates a condition in the motor or the driven load rather than a faulty relay. The most common causes are a mechanical jam or increased load, a current dial set below the motor’s full-load amperage, phase loss or voltage imbalance on the supply, high ambient temperature inside the enclosure, and a trip class too short for the motor’s acceleration time.

Applications for Overload Relays

Our overload relays are ideal for:

  • Motor protection for water pumps and industrial fans
  • Conveyor belt systems in manufacturing
  • HVAC system compressors and blower motors

Complete your motor control system with contactors and soft starters.

Why Choose Wistex for Overload Relays & Motor Protection

Protect your investments with overload relays from Wistex. Our selection of thermal and electronic overload relays from ABB provides vital protection against overcurrent, phase failure, and overheating — essential for industries like manufacturing, pumping, and HVAC.

Why choose Wistex for overload relays?

  • Specialized expertise in motor protection and system design
  • In-stock options for fast shipping when downtime isn’t an option
  • Top brands like ABB for unmatched reliability
  • Support beyond the sale — helping you with setup, replacement, and scaling needs

Keep your motors safe and your business moving forward with overload relays from Wistex.

FAQs about Overload Relays

Understand how overload relays protect your motors and improve operational reliability.

Overload relays detect excessive current flowing through a motor circuit. If the current exceeds a preset level for too long (indicating a jam, blockage, or overload), the relay trips to disconnect the motor, preventing overheating and mechanical damage.

Thermal overload relays use a mechanical bimetallic strip that bends when heated by excess current. Electronic overload relays use sensors and processors for faster, more precise detection of overload conditions, often with more flexible setting options.

Replace an overload relay if it trips frequently without valid cause, shows inconsistent operation, suffers visible damage, or if the protected motor has been upgraded to a higher horsepower. Routine inspection during maintenance can help catch early signs of failure.