Thermal and Electronic Overload Relays

What Is an Overload Relay?

An overload relay is a motor protection device that monitors the current drawn by a motor and disconnects it when that current stays above a set level for long enough to cause damage. It protects against sustained overload, phase loss, and current imbalance, all of which cause a motor to overheat. An overload relay does not provide short-circuit protection, which is handled separately by fuses or a circuit breaker.

Protect your motors from overcurrent and overheating with Eaton, ABB, WEG and Noark overload relays. Available in thermal and electronic options, our relays provide reliable motor protection for a variety of applications, including pumps, conveyors, and HVAC systems. Ensure your operations run smoothly and safely with the right motor protection solution from Wistex.

  • DRS-F-EF-02 | ABB Remote Stop Coil 48-60 V
    ABB

    DRS-F-EF-02

    Remote Stop Coil 48-60 V

    $47.49
    $65.02
  • DRS-F-EF-03 | ABB Remote Stop Coil 110-127 V
    ABB

    DRS-F-EF-03

    Remote Stop Coil 110-127 V

    $47.49
    $65.02
  • DRS-F-EF-04 | ABB Remote Stop Coil 220-240 V
    ABB

    DRS-F-EF-04

    Remote Stop Coil 220-240 V

    $47.49
    $65.02
  • DT450/A185 | ABB Ta450 Busbar Kit,A145-A185
    ABB

    DT450/A185

    Ta450 Busbar Kit,A145-A185

    $160.79
    $526.65
  • DT450/A300 | ABB Ta450 Bus Bar Kit,A210-A300
    ABB

    DT450/A300

    Ta450 Bus Bar Kit,A210-A300

    $160.79
    $296.65
  • DT500/AF460L | ABB Dt500/Af460-L Mounting Kit
    ABB

    DT500/AF460L

    Dt500/Af460-L Mounting Kit

    $377.08
    $516.28
  • DT500/AF460S | ABB Dt500/Af460-S Mounting Kit
    ABB

    DT500/AF460S

    Dt500/Af460-S Mounting Kit

    $377.08
    $516.28
  • DT800/AF750S | ABB Dt800/Af750-S Mounting Kit
    ABB

    DT800/AF750S

    Dt800/Af750-S Mounting Kit

    $396.18
    $542.43
  • E16DU0.32 | ABB E16Du-0.32 Electronic Overload Rela
    ABB

    E16DU0.32

    E16Du-0.32 Electronic Overload Rela

    $145.16
    $147.41
  • E16DU1.0 | ABB E16Du-1.0 Electronic Overload Relay
    ABB

    E16DU1.0

    E16Du-1.0 Electronic Overload Relay

    $145.16
    $147.41
  • E16DU18.9 | ABB E16Du-18.9 Electronic Overload Rela
    ABB

    E16DU18.9

    E16Du-18.9 Electronic Overload Rela

    $145.16
    $147.41
  • E16DU2.7 | ABB E16Du-2.7 Electronic Overload Relay
    ABB

    E16DU2.7

    E16Du-2.7 Electronic Overload Relay

    $145.16
    $147.41
  • E16DU6.3 | ABB E16Du-6.3 Electronic Overload Relay
    ABB

    E16DU6.3

    E16Du-6.3 Electronic Overload Relay

    $145.16
    $147.41
  • EF146-150 | ABB Eol,Af116-146,Class-102030,54-150A
    ABB

    EF146-150

    Eol,Af116-146,Class-102030,54-150A

    $453.45
    $620.85
  • EF19-0.32 | ABB Elec O/L 0.10-0.32A, Class 10E, 20
    ABB

    EF19-0.32

    Elec O/L 0.10-0.32A, Class 10E, 20

    $100.25
    $137.25
  • EF19-1.0 | ABB Elec O/L 0.30-1.0A, Class 10E, 20E
    ABB

    EF19-1.0

    Elec O/L 0.30-1.0A, Class 10E, 20E

    $100.25
    $137.25
  • EF370-380 | ABB Eol,Af265-370,Class-102030,115-380A
    ABB

    EF370-380

    Eol,Af265-370,Class-102030,115-380A

    $701.66
    $960.69
  • EF460 | ABB Electronic Overload 150-500 A
    ABB

    EF460

    Electronic Overload 150-500 A

    $906.91
    $1,241.71
  • EF750 | ABB Electronic Overload 250-800 A
    ABB

    EF750

    Electronic Overload 250-800 A

    $994.83
    $1,428.61
  • EF96-100 | ABB Eol,Af80-96,Class-10/20/30,36-100A
    ABB

    EF96-100

    Eol,Af80-96,Class-10/20/30,36-100A

    $410.49
    $562.03
  • EF96-56 | ABB Eol Af80-96 Class 10/20/30 20-56A
    ABB

    EF96-56

    Eol Af80-96 Class 10/20/30 20-56A

    $408.73
    $559.61
  • ERC250RW | Weg External Reset Cable
    Weg

    ERC250RW

    External Reset Cable

    $52.72
    $80.00
  • ERC375RW | Weg External Reset Cable
    Weg

    ERC375RW

    External Reset Cable

    $52.72
    $80.00
  • ERC500RW | Weg External Reset Cable
    Weg

    ERC500RW

    External Reset Cable

    $52.72
    $80.00
  • Ex9R100B104A Noark Thermal Overload Relay (80-100 Amps)
    Noark

    Ex9R100B104A

    Thermal Overload Relay (80-100 Amps)

    $98.67
  • Ex9R100B32A Noark Thermal Overload Relay (23-32 Amps)
    Noark

    Ex9R100B32A

    Thermal Overload Relay (23-32 Amps)

    $112.99
  • Ex9R100B40A Noark Thermal Overload Relay (30-40 Amps)
    Noark

    Ex9R100B40A

    Thermal Overload Relay (30-40 Amps)

    $83.87
  • Ex9R100B50A Noark Thermal Overload Relay (37-50 Amps)
    Noark

    Ex9R100B50A

    Thermal Overload Relay (37-50 Amps)

    $74.01
    $80.00

Overload Relays We Offer

Wistex offers a full range of overload relays designed to protect motors from overheating, phase loss, and excessive current. Whether you need thermal or electronic protection, we provide reliable solutions for industrial applications across manufacturing, pumping, and HVAC systems.

Thermal Overload Relays

Thermal overload relays use a bimetallic strip that reacts to heat generated by excess current. As the strip bends, it pushes a mechanical trip bar that changes the state of the relay’s internal contacts, opening the control circuit and dropping out the contactor that feeds the motor.

Electronic Overload Relays

Electronic overload relays use digital sensors to detect current surges with greater precision and speed. They offer adjustable settings, diagnostics, and advanced features like phase failure detection. Electronic relays are well-suited for applications requiring flexible, programmable motor protection and integration with control systems.

Trip class defines how long a relay will carry six times its rated current before tripping. Class 10 trips within ten seconds and suits standard motors; Class 20 within twenty seconds where starting takes longer; and Class 30 within thirty seconds for high-inertia loads such as large fans. Electronic relays use the equivalent 10E, 20E, and 30E designations.

Because sensing does not depend on a heated metal strip, electronic relays are less prone to false trips when the ambient temperature inside the enclosure changes.

Parts of a Thermal Overload Relay

A thermal overload relay has a current adjustment dial set to the motor’s full-load amperage. Its normally closed contacts, numbered 95 and 96, wire in series with the contactor coil, so a trip drops out the contactor. The normally open contacts, 97 and 98, signal an alarm or indicator light. A separate selector sets manual or automatic reset once the bimetallic strip cools.

Why Does an Overload Relay Keep Tripping?

Repeated tripping usually indicates a condition in the motor or the driven load rather than a faulty relay. The most common causes are a mechanical jam or increased load, a current dial set below the motor’s full-load amperage, phase loss or voltage imbalance on the supply, high ambient temperature inside the enclosure, and a trip class too short for the motor’s acceleration time.

Applications for Overload Relays

Our overload relays are ideal for:

  • Motor protection for water pumps and industrial fans
  • Conveyor belt systems in manufacturing
  • HVAC system compressors and blower motors

Complete your motor control system with contactors and soft starters.

Why Choose Wistex for Overload Relays & Motor Protection

Protect your investments with overload relays from Wistex. Our selection of thermal and electronic overload relays from ABB provides vital protection against overcurrent, phase failure, and overheating — essential for industries like manufacturing, pumping, and HVAC.

Why choose Wistex for overload relays?

  • Specialized expertise in motor protection and system design
  • In-stock options for fast shipping when downtime isn’t an option
  • Top brands like ABB for unmatched reliability
  • Support beyond the sale — helping you with setup, replacement, and scaling needs

Keep your motors safe and your business moving forward with overload relays from Wistex.

FAQs about Overload Relays

Understand how overload relays protect your motors and improve operational reliability.

Overload relays detect excessive current flowing through a motor circuit. If the current exceeds a preset level for too long (indicating a jam, blockage, or overload), the relay trips to disconnect the motor, preventing overheating and mechanical damage.

Thermal overload relays use a mechanical bimetallic strip that bends when heated by excess current. Electronic overload relays use sensors and processors for faster, more precise detection of overload conditions, often with more flexible setting options.

Replace an overload relay if it trips frequently without valid cause, shows inconsistent operation, suffers visible damage, or if the protected motor has been upgraded to a higher horsepower. Routine inspection during maintenance can help catch early signs of failure.