Eaton
EBR-3000-2B0DB1
EBR-3000, PROFIBUS (FO ST), CC, PM
$5,235.48$5,659.98 -
Eaton
EBR-3000-2B0EA0
EBR-3000, PROFIBUS (D-SUB), SM
$4,686.10$5,066.05 -
Eaton
EBR-3000-2B0EA1
EBR-3000, PROFIBUS (D-SUB), PM
$4,761.28$5,147.33 -
Eaton
EBR-3000-2B0EB0
EBR-3000, PROFIBUS (D-SUB), CC, SM
$5,052.36$5,462.01 -
Eaton
EBR-3000-2B0EB1
EBR-3000, PROFIBUS (D-SUB), CC, PM
$5,125.61$5,541.20 -
Eaton
EBR-3000-2B0FA0
EBR-3000, MODBUS/DNP3 (FO ST), SM
$4,462.50$4,824.33 -
Eaton
EBR-3000-2B0FA1
EBR-3000, MODBUS/DNP3 (FO ST), PM
$4,537.66$4,905.59 -
Eaton
EBR-3000-2B0FB0
EBR-3000, MODBUS/DNP3 (FO ST), CC, SM
$4,826.81$5,218.17 -
Eaton
EBR-3000-2B0FB1
EBR-3000, MODBUS/DNP3 (FO ST), CC, PM
$4,902.01$5,299.47 -
Eaton
EBR-3000-2B0GA0
EBR-3000, MODBUS/DNP3 (D-SUB), SM
$4,277.45$4,624.27 -
Eaton
EBR-3000-2B0GA1
EBR-3000, MODBUS/DNP3 (D-SUB), PM
$4,352.63$4,705.53 -
Eaton
EBR-3000-2B0GB0
EBR-3000, MODBUS/DNP3 (D-SUB), CC, SM
$4,639.83$5,016.03 -
Eaton
EBR-3000-2B0GB1
EBR-3000, MODBUS/DNP3 (D-SUB), CC, PM
$4,716.94$5,099.39 -
Eaton
EBR-3000-2B0HA0
EBR-3000, 61850/MODBUS/DNP3 (RJ45), SM
$5,391.63$5,828.79 -
Eaton
EBR-3000-2B0HA1
EBR-3000, 61850/MODBUS/DNP3 (RJ45), PM
$5,466.78$5,910.03 -
Eaton
EBR-3000-2B0HB0
EBR-3000, 61850/MODBUS/DNP3 (RJ45), CC,
$5,755.94$6,222.63 -
Eaton
EBR-3000-2B0HB1
EBR-3000, 61850/MODBUS/DNP3 (RJ45), CC,
$5,831.11$6,303.91 -
Eaton
EBR-3000-2B0IA0
EBR-3000, MODBUS/DNP3 (RS485 OR RJ45), S
$4,410.45$4,768.05 -
Eaton
EBR-3000-2B0IA1
EBR-3000, MODBUS/DNP3 (RS485 OR RJ45), P
$4,485.64$4,849.34 -
Eaton
EBR-3000-2B0IB0
EBR-3000, MODBUS/DNP3 (RS485 OR RJ45), C
$4,774.78$5,161.91 -
Eaton
EBR-3000-2B0IB1
EBR-3000, MODBUS/DNP3 (RS485 OR RJ45), C
$4,849.95$5,243.18 -
Eaton
EBR-3000-2B0KA0
EBR-3000, 61850/MODBUS/DNP3 (FO LC), SM
$5,578.60$6,030.91 -
Eaton
EBR-3000-2B0KA1
EBR-3000, 61850/MODBUS/DNP3 (FO LC), PM
$5,651.85$6,110.11 -
Eaton
EBR-3000-2B0KB0
EBR-3000, 61850/MODBUS/DNP3 (FO LC), CC,
$5,942.94$6,424.79 -
Eaton
EBR-3000-2B0KB1
EBR-3000, 61850/MODBUS/DNP3 (FO LC), CC,
$6,016.19$6,503.98 -
Eaton
EBR-3000-2B0LA0
EBR-3000, MODBUS/DNP3 (FO LC), SM
$4,574.29$4,945.18 -
Eaton
EBR-3000-2B0LA1
EBR-3000, MODBUS/DNP3 (FO LC), PM
$4,647.54$5,024.37 -
Eaton
EBR-3000-2B0LB0
EBR-3000, MODBUS/DNP3 (FO LC), CC, SM
$4,938.61$5,339.04
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.