Tele Controls
E1YM400VS10
3-phase mains, multifunction monitoring , 1 co
$153.39 -
Tele Controls
E1YU400V01
3-phase mains, undervoltage monitoring , 1 co
$145.42 -
Tele Controls
E1ZI10 12-240VAC/DC
Clock generator - two-time multifunction relay, 1 changeover contact, 50ms-100hrs, SPDT, 12-240V AC/DC, two separate time ranges
$94.38 -
Tele Controls
E1ZMLA10 24-240VAC/DC
pump alternator + time relay (5 fct.), 1 changeover contact, 24-240V AC/DC, duplexor relay SPDT, 50ms-100hrs
$72.71 -
Tele Controls
E1ZMQ10 24-240VAC/DC
Multifunction (4 fct.), 1 changeover contact, SPDT, 24-240V AC/DC, 50ms-100hrs, comparable to EATON TRL04
$58.78 -
Tele Controls
E3IF500MAAC20 230V AC
1 mains, current monitoring, 2 CO
$169.13 -
Tele Controls
E3IM10AL20 230V AC
1 mains, current monitoring, 2 CO
$229.70 -
Tele Controls
E3K 12-240V AC/DC
Coupling Relay, 12-240V AC/DC, 2CO
$101.41 -
Tele Controls
E3LM10 230V AC
Pump Up, Down Relay, SPDT Relay Output, 230V AC Supply
$152.19 -
Tele Controls
E3PF400VSY02
3-phase mains, monitoring of phase sequence, phase failure and asymmetry, 2 CO
$193.99 -
Tele Controls
E3YF400V02 0.85
3 phase mains, Undervoltage monitoring, 2 CO
$169.30 -
Tele Controls
E3YF400VE20 0.85
3 phase mains, undervoltage monitoring, 2 CO
$179.44 -
Tele Controls
E3YF400VT02 0.85
3 phase mains, undervoltage monitoring, 2 CO
$182.08 -
Tele Controls
E3YM230VS20
3-ph Voltage Monitoring, 230VAC, 2CO (DPDT), LED Indication, DIN Rail
$220.49 -
Tele Controls
E3YM400VSY20
3 phase mains, multifunction monitoring, 400VAC 2 CO
$162.34 -
Tele Controls
E3YU400V02
3-phase mains, undervoltage monitoring, 2 CO
$152.19 -
Eaton
EASY-E4-UC-12RC1P
Nano Programmable Logic Controller with Display (12/24V DC, 24 V AC)
$295.26 -
Eaton
EBR-3000-2B0BA0
EBR-3000, MODBUS/DNP3 (RS485), SM
$4,129.01$4,463.79 -
Eaton
EBR-3000-2B0BA1
EBR-3000, MODBUS/DNP3 (RS485), PM
$4,202.24$4,542.97 -
Eaton
EBR-3000-2B0BB0
EBR-3000, MODBUS/DNP3 (RS485), CC, SM
$4,493.34$4,857.67 -
Eaton
EBR-3000-2B0BB1
EBR-3000, MODBUS/DNP3 (RS485), CC, PM
$4,566.56$4,936.83 -
Eaton
EBR-3000-2B0CA0
EBR-3000, MODBUS/DNP3 (RJ45), SM
$4,315.99$4,665.93 -
Eaton
EBR-3000-2B0CA1
EBR-3000, MODBUS/DNP3 (RJ45), PM
$4,389.24$4,745.13 -
Eaton
EBR-3000-2B0CB0
EBR-3000, MODBUS/DNP3 (RJ45), CC, SM
$4,680.31$5,059.79 -
Eaton
EBR-3000-2B0CB1
EBR-3000, MODBUS/DNP3 (RJ45), CC, PM
$4,753.56$5,138.99 -
Eaton
EBR-3000-2B0DA0
EBR-3000, PROFIBUS (FO ST), SM
$4,797.93$5,186.93 -
Eaton
EBR-3000-2B0DA1
EBR-3000, PROFIBUS (FO ST), PM
$4,871.15$5,266.12 -
Eaton
EBR-3000-2B0DB0
EBR-3000, PROFIBUS (FO ST), CC, SM
$5,162.23$5,580.78
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.