Electrical Relays

  • EBR-3Z-2B0LB1-B | Eaton EBR-3000+EBR-Z, MODBUS/DNP3 (FO LC), CC,
    Eaton

    EBR-3Z-2B0LB1-B

    EBR-3000+EBR-Z, MODBUS/DNP3 (FO LC), CC,

    $10,929.73
    $11,815.92
  • EBR-3Z-2B0TA0-A | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TA0-A

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $10,197.24
    $11,024.04
  • EBR-3Z-2B0TA0-B | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TA0-B

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $11,720.05
    $12,670.33
  • EBR-3Z-2B0TA1-A | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TA1-A

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $10,274.33
    $11,107.37
  • EBR-3Z-2B0TA1-B | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TA1-B

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $11,797.18
    $12,753.71
  • EBR-3Z-2B0TB0-A | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TB0-A

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $10,563.46
    $11,419.97
  • EBR-3Z-2B0TB0-B | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TB0-B

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $12,086.34
    $13,066.30
  • EBR-3Z-2B0TB1-A | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TB1-A

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $10,630.95
    $11,492.91
  • EBR-3Z-2B0TB1-B | Eaton EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R
    Eaton

    EBR-3Z-2B0TB1-B

    EBR-3000+EBR-Z, 61850/MDBS/DNP3 (RS485 R

    $12,163.41
    $13,149.63
  • EBR-Z-2A0 | Eaton EBR-Z HIGH IMPEDANCE MODULE, 5200 JOULE,
    Eaton

    EBR-Z-2A0

    EBR-Z HIGH IMPEDANCE MODULE, 5200 JOULE,

    $4,462.50
    $4,824.33
  • EBR-Z-2A1 | Eaton EBR-Z HIGH IMPEDANCE MODULE, 5200 JOULE,
    Eaton

    EBR-Z-2A1

    EBR-Z HIGH IMPEDANCE MODULE, 5200 JOULE,

    $4,537.66
    $4,905.59
  • EBR-Z-2B0 | Eaton EBR-Z HIGH IMPEDANCE MODULE, 10400 JOULE
    Eaton

    EBR-Z-2B0

    EBR-Z HIGH IMPEDANCE MODULE, 10400 JOULE

    $5,987.29
    $6,472.74
  • EBR-Z-2B1 | Eaton EBR-Z HIGH IMPEDANCE MODULE, 10400 JOULE
    Eaton

    EBR-Z-2B1

    EBR-Z HIGH IMPEDANCE MODULE, 10400 JOULE

    $6,060.50
    $6,551.89
  • ECS20BC Littelfuse Current Sensor
    Littelfuse

    ECS20BC

    Current Sensor

    $381.58
  • ECS21BC Littelfuse Current Sensor
    Littelfuse

    ECS21BC

    Current Sensor

    $381.58
  • ECS2HBC Littelfuse Current Sensor
    Littelfuse

    ECS2HBC

    Current Sensor

    $381.58
  • ECS30AC Littelfuse Current Sensor
    Littelfuse

    ECS30AC

    Current Sensor

    $381.58
  • ECS31AC Littelfuse Current Sensor
    Littelfuse

    ECS31AC

    Current Sensor

    $381.58
  • ECS40A Littelfuse Current Sensor
    Littelfuse

    ECS40A

    Current Sensor

    $381.58
  • ECS40AC Littelfuse Current Sensor
    Littelfuse

    ECS40AC

    Current Sensor

    $381.58
  • ECS40BC Littelfuse Current Sensor
    Littelfuse

    ECS40BC

    Current Sensor

    $381.58
  • ECS41A Littelfuse Current Sensor
    Littelfuse

    ECS41A

    Current Sensor

    $381.58
  • ECS41AC Littelfuse Current Sensor
    Littelfuse

    ECS41AC

    Current Sensor

    $381.58
  • ECS41BC Littelfuse Current Sensor
    Littelfuse

    ECS41BC

    Current Sensor

    $381.58
  • ECS41BD Littelfuse Current Sensor
    Littelfuse

    ECS41BD

    Current Sensor

    $381.58
  • ECS41BH Littelfuse Current Sensor
    Littelfuse

    ECS41BH

    Current Sensor

    $381.58
  • ECS4HBC Littelfuse Current Sensor
    Littelfuse

    ECS4HBC

    Current Sensor

    $381.58
  • ECS4HBH Littelfuse Current Sensor
    Littelfuse

    ECS4HBH

    Current Sensor

    $381.58

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.