Littelfuse
CT-0400-F20
400:5 Ct/ 2 In. Window/ Footed
$231.96 -
Littelfuse
CT-0400-F30
400:5 Ct/ 3 In. Window/ Footed
$380.75 -
Littelfuse
CT-0500-D20
500:5 Ct/ 2 In. Window/ Donut
$307.72 -
Littelfuse
CT-0600-F20
600:5 Ct/ 2 In. Window/ Footed
$231.96 -
Littelfuse
CT-0800-F30
800:5 Ct/ 3 In. Window/Footed
$380.75 -
Littelfuse
CT-1200-F15
1200:5 Ft W/ 1.5 Win. Mod 2560
$260.41 -
Littelfuse
CT0T08-PC
Socket Octal 8 Pin
$29.36 -
ATC
CT100/5
Current Transformer 100/5 amp
$25.32$25.91 -
ATC
CT1000/5
Current Transformer 1000/5 amp
$39.40$40.79 -
Littelfuse
CT1S30
On/Off Timing Module
$120.40 -
Littelfuse
CT1S45
On/Off Timing Module
$120.40 -
Littelfuse
CT1S8
On/Off Timing Module
$120.40 -
Littelfuse
CT1S90
On/Off Timing Module
$120.40 -
Littelfuse
CT200
Current Transformer
$371.85 -
ATC
CT200/5
Current Transformer 200/5 amp
$17.20$19.85 -
Littelfuse
CT200L
Current Transformer
$485.86 -
ATC
CT30/5
Current Transformer 30/5 amp
$27.26 -
Littelfuse
CT30S1
On/Off Timing Module
$120.40 -
Littelfuse
CT45S45
On/Off Timing Module
$120.40 -
ATC
CT50/5
Current Transformer 50/5 amp
$26.07 -
ATC
CT500/5
Current Transformer 500/5 amp
$42.45 -
Littelfuse
CT5S300
On/Off Timing Module
$120.40 -
ATC
CTDRC
Current Transformer DIN Rail Clamp For all CT30 thru CT1000 units
$26.85$27.80 -
RK Electronics
CUB-115A-0001
Back-Up Controller, 115VAC, Pump Down
$282.35$400.00 -
ATC
CV-120RS
Voltage Monitor Appliance Control
$200.98$208.07 -
Eaton
D3RF3T
Ice Cube Relay (10A, 24VAC Coil)
$29.51$53.65 -
Eaton
D64RP18
Basic Digital Ground Fault Relay Unit c/w Built-In CT
-
Eaton
D64RPB30
GROUND FAULT RELAY
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.