Electrical Relays

  • 1SVR500100R0100 | ABB Ct-Erd.22 On-Delay Timer
    ABB

    1SVR500100R0100

    Ct-Erd.22 On-Delay Timer

    $130.94
    $193.41
  • 1SVR500110R0000 | ABB Ct-Ahd Off-Del Tim. 24-240Vac/48Vdc
    ABB

    1SVR500110R0000

    Ct-Ahd Off-Del Tim. 24-240Vac/48Vdc

    $78.70
    $116.25
  • 1SVR500110R0100 | ABB Ct-Ahd.22 Off-Delay Timers
    ABB

    1SVR500110R0100

    Ct-Ahd.22 Off-Delay Timers

    $130.94
    $193.41
  • 1SVR500130R0000 | ABB Ct-Vwd Imp-On 24-240Vac/48Vdc 1C/O
    ABB

    1SVR500130R0000

    Ct-Vwd Imp-On 24-240Vac/48Vdc 1C/O

    $66.01
    $97.51
  • 1SVR500150R0000 | ABB Ct-Ebd Flasher 24-240Vac/48Vdc
    ABB

    1SVR500150R0000

    Ct-Ebd Flasher 24-240Vac/48Vdc

    $66.01
    $97.51
  • 1SVR500160R0000 | ABB Ct-Tgd Pulse Timer 24-240Vac/48Vdc
    ABB

    1SVR500160R0000

    Ct-Tgd Pulse Timer 24-240Vac/48Vdc

    $77.35
    $114.26
  • 1SVR500160R0100 | ABB Ct-Tgd.22 Time Relay Pluse Gen.
    ABB

    1SVR500160R0100

    Ct-Tgd.22 Time Relay Pluse Gen.

    $150.11
    $195.25
  • 1SVR500211R0100 | ABB Ct-Sdd.22 Timer Star-Delta
    ABB

    1SVR500211R0100

    Ct-Sdd.22 Timer Star-Delta

    $121.49
    $158.00
  • 1SVR508010R1300 ABB 1C/O, 24-48VDC/24-240VAC
    ABB

    1SVR508010R1300

    1C/O, 24-48VDC/24-240VAC

    $158.86
    $394.80
  • 1SVR508020R0000 | ABB Ct-Mfc.12 1C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508020R0000

    Ct-Mfc.12 1C/O, 24-48Vdc/24-240Vac

    $141.05
    $208.35
  • 1SVR508020R1100 | ABB Ct-Mfc.21 2C/O, 12-240Vac/Dc
    ABB

    1SVR508020R1100

    Ct-Mfc.21 2C/O, 12-240Vac/Dc

    $169.24
    $249.98
  • 1SVR508100R0100 | ABB Ct-Erc.22 2C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508100R0100

    Ct-Erc.22 2C/O, 24-48Vdc/24-240Vac

    $116.81
    $172.54
  • 1SVR508110R0000 | ABB Ct-Ahc.12 1C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508110R0000

    Ct-Ahc.12 1C/O, 24-48Vdc/24-240Vac

    $126.11
    $186.28
  • 1SVR508110R0100 | ABB Ct-Ahc.22 2C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508110R0100

    Ct-Ahc.22 2C/O, 24-48Vdc/24-240Vac

    $149.88
    $372.47
  • 1SVR508130R0000 | ABB Ct-Vwc.12 1C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508130R0000

    Ct-Vwc.12 1C/O, 24-48Vdc/24-240Vac

    $96.40
    $239.58
  • 1SVR508160R0000 | ABB Ct-Tgc.12 1C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508160R0000

    Ct-Tgc.12 1C/O, 24-48Vdc/24-240Vac

    $126.11
    $186.28
  • 1SVR508160R0100 | ABB Ct-Tgc.22 2C/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508160R0100

    Ct-Tgc.22 2C/O, 24-48Vdc/24-240Vac

    $149.88
    $372.47
  • 1SVR508210R0100 | ABB Ct-Sac.22 2N/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508210R0100

    Ct-Sac.22 2N/O, 24-48Vdc/24-240Vac

    $122.85
    $181.46
  • 1SVR508211R0100 | ABB Ct-Sdc.22 2N/O, 24-48Vdc/24-240Vac
    ABB

    1SVR508211R0100

    Ct-Sdc.22 2N/O, 24-48Vdc/24-240Vac

    $97.38
    $143.83
  • 1SVR550019R0000 | ABB Ct-Mke Solid-State Output
    ABB

    1SVR550019R0000

    Ct-Mke Solid-State Output

    $72.24
    $193.88
  • 1SVR550100R4100 | ABB Ct-Ere On-Delay Timer 110V 0.3-30S
    ABB

    1SVR550100R4100

    Ct-Ere On-Delay Timer 110V 0.3-30S

    $57.16
    $153.40
  • 1SVR550100R5100 | ABB Ct-Ere Time Relay On-Delay
    ABB

    1SVR550100R5100

    Ct-Ere Time Relay On-Delay

    $57.16
    $153.40
  • 1SVR550107R5100 | ABB Ct-Ere Time Relay On-Delay
    ABB

    1SVR550107R5100

    Ct-Ere Time Relay On-Delay

    $57.16
    $153.40

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.