Electrical Relays

  • 1SVR450056R0100 | ABB Cm-Se-600 Screw-In Bar Electrode
    ABB

    1SVR450056R0100

    Cm-Se-600 Screw-In Bar Electrode

    $28.46
    $37.00
  • 1SVR450056R0200 | ABB Cm-Se-1000 Screw-In Bar Electrode
    ABB

    1SVR450056R0200

    Cm-Se-1000 Screw-In Bar Electrode

    $21.45
    $53.30
  • 1SVR450116R1000 | ABB Cm-Ct 50/1 Current Transformer
    ABB

    1SVR450116R1000

    Cm-Ct 50/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450116R1100 | ABB Cm-Ct 75/1 Current Transformer
    ABB

    1SVR450116R1100

    Cm-Ct 75/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450116R1200 | ABB Cm-Ct 100/1 Current Transformer
    ABB

    1SVR450116R1200

    Cm-Ct 100/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450116R1300 | ABB Cm-Ct 150/1 Current Transformer
    ABB

    1SVR450116R1300

    Cm-Ct 150/1 Current Transformer

    $91.11
    $118.48
  • 1SVR450116R1400 | ABB Cm-Ct 200/1 Current Transformer
    ABB

    1SVR450116R1400

    Cm-Ct 200/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450116R5000 | ABB Cm-Ct 50/5 Current Transformer
    ABB

    1SVR450116R5000

    Cm-Ct 50/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450116R5100 | ABB Cm-Ct 75/5 Current Transformer
    ABB

    1SVR450116R5100

    Cm-Ct 75/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450116R5200 | ABB Cm-Ct 100/5 Current Transformer
    ABB

    1SVR450116R5200

    Cm-Ct 100/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450116R5300 | ABB Cm-Ct 150/5 Current Transformer
    ABB

    1SVR450116R5300

    Cm-Ct 150/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450116R5400 | ABB Cm-Ct 200/5 Current Transformer
    ABB

    1SVR450116R5400

    Cm-Ct 200/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450117R1100 | ABB Cm-Ct 300/1 Current Transformer
    ABB

    1SVR450117R1100

    Cm-Ct 300/1 Current Transformer

    $91.11
    $118.48
  • 1SVR450117R1200 | ABB Cm-Ct 400/1 Current Transformer
    ABB

    1SVR450117R1200

    Cm-Ct 400/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450117R1300 | ABB Cm-Ct 500/1 Current Transformer
    ABB

    1SVR450117R1300

    Cm-Ct 500/1 Current Transformer

    $91.96
    $135.84
  • 1SVR450117R1400 | ABB Cm-Ct 600/1 Current Transformer
    ABB

    1SVR450117R1400

    Cm-Ct 600/1 Current Transformer

    $91.11
    $118.48
  • 1SVR450117R5100 | ABB Cm-Ct 300/5 Current Transformer
    ABB

    1SVR450117R5100

    Cm-Ct 300/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450117R5200 | ABB Cm-Ct 400/5 Current Transformer
    ABB

    1SVR450117R5200

    Cm-Ct 400/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450117R5300 | ABB Cm-Ct 500/5 Current Transformer
    ABB

    1SVR450117R5300

    Cm-Ct 500/5 Current Transformer

    $80.44
    $118.82
  • 1SVR450117R5400 | ABB Cm-Ct 600/5 Current Transformer
    ABB

    1SVR450117R5400

    Cm-Ct 600/5 Current Transformer

    $77.59
    $114.61
  • 1SVR450118R1000 | ABB Snap-On Mounting For Cm-Ct Din Rail
    ABB

    1SVR450118R1000

    Snap-On Mounting For Cm-Ct Din Rail

    $14.66
    $21.66
  • 1SVR450330R0000 | ABB Cm-Lwn Motor Load Mon. 3Ph. 110V
    ABB

    1SVR450330R0000

    Cm-Lwn Motor Load Mon. 3Ph. 110V

    $479.29
    $585.43
  • 1SVR500020R0000 | ABB Ct-Mfd.12 Multifunction Timer 1C/O
    ABB

    1SVR500020R0000

    Ct-Mfd.12 Multifunction Timer 1C/O

    $81.41
    $120.26
  • 1SVR500020R1100 | ABB Ct-Mfd.21 Multifunction Timer 2C/O
    ABB

    1SVR500020R1100

    Ct-Mfd.21 Multifunction Timer 2C/O

    $173.59
    $182.60
  • 1SVR500100R0000 | ABB Ct-Erd On-Del Timer 24-240Vac/48Vdc
    ABB

    1SVR500100R0000

    Ct-Erd On-Del Timer 24-240Vac/48Vdc

    $65.40
    $162.52

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.