Electrical Relays

  • G2TF01 Tele Controls Temperature monitoring, 1 CO
    Tele Controls

    G2TF01

    Temperature monitoring, 1 CO

    $169.13
  • G2TF02 230VAC Tele Controls Temperature monitoring, 2 CO
    Tele Controls

    G2TF02 230VAC

    Temperature monitoring, 2 CO

    $203.00
  • G2TF02 Tele Controls Temperature monitoring, 2 CO
    Tele Controls

    G2TF02

    Temperature monitoring, 2 CO

    $197.44
  • G2TFK02 24-240V AC/DC Tele Controls Temperature monitoring, short-circuit monitoring, 2 CO, 24-240V AC/DC
    Tele Controls

    G2TFK02 24-240V AC/DC

    Temperature monitoring, short-circuit monitoring, 2 CO, 24-240V AC/DC

    $304.99
  • G2TFKN02 24-240VAC/DC Tele Controls Temperature monitoring, short-circuit monitoring, zero-voltage latch, 2 CO, 24-240V AC/DC
    Tele Controls

    G2TFKN02 24-240VAC/DC

    Temperature monitoring, short-circuit monitoring, zero-voltage latch, 2 CO, 24-240V AC/DC

    $213.97
  • G2TFKN02 Tele Controls Temperature monitoring, short-circuit monitoring, zero-voltage latch, 2 CO
    Tele Controls

    G2TFKN02

    Temperature monitoring, short-circuit monitoring, zero-voltage latch, 2 CO

    $212.99
  • G2TMPT100L20 24-240VAC/DC Tele Controls Temperature monitoring, PT100, multifunction, 2 CO, 24-240VAC/DC
    Tele Controls

    G2TMPT100L20 24-240VAC/DC

    Temperature monitoring, PT100, multifunction, 2 CO, 24-240VAC/DC

    $219.92
  • G2UM300VL20 24-240VAC/DC Tele Controls Voltage monitoring 1-phase, 1.5-300V, multifunction, 2 changeover contacts, DPDT, 24-240V AC/DC
    Tele Controls

    G2UM300VL20 24-240VAC/DC

    Voltage monitoring 1-phase, 1.5-300V, multifunction, 2 changeover contacts, DPDT, 24-240V AC/DC

    $283.49
  • G2UM300VL20 Tele Controls 1-phase mains, multifunction, 2 CO
    Tele Controls

    G2UM300VL20

    1-phase mains, multifunction, 2 CO

    $236.83
  • G2YM400VL20 Tele Controls 3-phase mains, multifunction, 2 CO
    Tele Controls

    G2YM400VL20

    3-phase mains, multifunction, 2 CO

    $270.72
  • G4BM480V12ADTL20 24-240V AC/DC Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding, DIGITAL SETTING
    Tele Controls

    G4BM480V12ADTL20 24-240V AC/DC

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding, DIGITAL SETTING

    $795.52
  • G4BM480V12ADTL20 Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding
    Tele Controls

    G4BM480V12ADTL20

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding

    $778.59
  • G4BM480V12AFTL20 Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding
    Tele Controls

    G4BM480V12AFTL20

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding

    $761.65
  • G4BM480V12ATL20 Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding
    Tele Controls

    G4BM480V12ATL20

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding

    $761.65
  • G4BM690V16AL20 Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding
    Tele Controls

    G4BM690V16AL20

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding

    $846.31
  • G4BM690V16ATL20 Tele Controls 1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding
    Tele Controls

    G4BM690V16ATL20

    1 or 3 phase mains, multifunction, 2 co, temperature monitoring of the motor winding

    $856.48
  • G4CM690V16ATL20 Tele Controls 1 or 3 phase mains, power factor detection (cos phi), multifunction, 2 co
    Tele Controls

    G4CM690V16ATL20

    1 or 3 phase mains, power factor detection (cos phi), multifunction, 2 co

    $856.48
  • G4PM500VSYL20 Tele Controls 3-phase mains, multifunction, monitoring for phase sequenz and asymmetry, 2 CO
    Tele Controls

    G4PM500VSYL20

    3-phase mains, multifunction, monitoring for phase sequenz and asymmetry, 2 CO

    $424.99
  • G4PM690VSYL20 Tele Controls 3-phase mains, multifunction, monitoring for phase sequenz and asymmetry, 2 CO
    Tele Controls

    G4PM690VSYL20

    3-phase mains, multifunction, monitoring for phase sequenz and asymmetry, 2 CO

    $372.27
  • G4UF900V01 230V AC Tele Controls 1-phase mains, 900V DC, undervoltage monitoring, 2 CO, 230V AC
    Tele Controls

    G4UF900V01 230V AC

    1-phase mains, 900V DC, undervoltage monitoring, 2 CO, 230V AC

    $423.08
  • GFD-100 ATC Three Phase Ground Fault Display
    ATC

    GFD-100

    Three Phase Ground Fault Display

    $541.01
    $560.10
  • GFD-200 ATC Three Phase Ground Fault Display
    ATC

    GFD-200

    Three Phase Ground Fault Display

    $541.12
    $560.22
  • GT434 (Digital Pressure Indicator)
    Gentran

    GT434

    Digital Pressure Indicator

    $712.24
  • HB/ES15 Tele Controls retaining clip for relay socket series RA, RM (ES15..)
    Tele Controls

    HB/ES15

    retaining clip for relay socket series RA, RM (ES15..)

    $1.01
  • HB/PSS Tele Controls retaining clip for PSS8/3
    Tele Controls

    HB/PSS

    retaining clip for PSS8/3

    $1.10
  • HB/RM-RA Tele Controls Retaining clip for relay socket series RA, RM (ES15..), RSS214
    Tele Controls

    HB/RM-RA

    Retaining clip for relay socket series RA, RM (ES15..), RSS214

    $1.01

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.