Littelfuse
HRDR330A0R
Recycling Timer
$233.60 -
Littelfuse
HRDR331A1
Recycling Timer
$233.60 -
Littelfuse
HRDR411SB30MR
Recycling Timer
$233.60 -
Littelfuse
HRDR431A1R
Recycling Timer
$233.60 -
Littelfuse
HRDS120
Single Shot Timer
$233.60 -
Littelfuse
HRDS313M
Single Shot Timer
$233.60 -
Littelfuse
HRDS321
Single Shot Timer
$233.60 -
Littelfuse
HRDS421
Single Shot Timer
$233.60 -
Littelfuse
HRISW21FT
Time Delay Relay
$258.52 -
Littelfuse
HRISW25B
Time Delay Relay
$258.52 -
Littelfuse
HRISW27I
Time Delay Relay
$258.52 -
Littelfuse
HRPSD12HI
Programmable Timer
$258.52 -
Littelfuse
HRV11SC
Coin Counter
$355.11 -
Littelfuse
HRV24AC
Coin Counter
$355.11 -
Littelfuse
HRV41AE
Coin Counter
$355.11 -
Littelfuse
HRV41SE
Coin Counter
$355.11 -
Littelfuse
HRV42SE
Coin Counter
$355.11 -
Littelfuse
HRV43AE
Coin Counter
$355.11 -
Littelfuse
HRV43AN
Coin Counter
$355.11 -
Littelfuse
HSPZA22SL
Timing Module
$178.14$249.82 -
Littelfuse
INFORMER
Remote Diagnostic Tool For Sin
$580.30 -
Littelfuse
INFORMER-MS
Remote Diagnostic Tool For Mod
$580.30 -
Eaton
IQ250/260-IO1
IQ250/260 I/O CARD-2 RELAY OUTPUTS/2 STATUS INPUTS
$1,834.74$1,983.51 -
Eaton
IQ250/260-IO2
IQ250/260 I/O CARD-4 KYZ PULSES/4 STATUS INPUTS
$3,870.28$4,184.08 -
Eaton
IQ250/260-IO3
IQ250/260 I/O CARD-4 ANALOG OUTPUTS- 0-1 MA
$3,544.21$3,831.58 -
Eaton
IQ250/260-IO4
IQ250/260 I/O CARD-4 ANALOG OUTPUTS- 4-20 MA
$2,261.96$2,445.36 -
Littelfuse
IR KIT-36
Fiber-Optic Kit 36"
$18.95$26.57 -
RK Electronics
IS1R-120A-R-10K
1 Channel IS Relay Din 120VAC, 10K Ohms
$232.94$330.00
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.