Eaton
ETR-5000-2B3KA0
ETR-5000, 8I/9O/2AI/2AO/ZSI, 61850/MODBUS/DNP3 (FO LC), SM
$19,247.50$20,808.11 -
Eaton
ETR-5000-2B3KA1
ETR-5000, 8I/9O/2AI/2AO/ZSI, 61850/MODBUS/DNP3 (FO LC), PM
$19,343.89$20,912.30 -
Eaton
ETR-5000-2B3KB0
ETR-5000, 8I/9O/2AI/2AO/ZSI, 61850/MODBUS/DNP3 (FO LC), SM
$20,635.40$22,308.53 -
Eaton
ETR-5000-2B3KB1
ETR-5000, 8I/9O/2AI/2AO/ZSI, 61850/MODBUS/DNP3 (FO LC), PM
$20,731.78$22,412.74 -
Eaton
ETR-5000-2B3LA0
ETR-5000, 8I/9O/2AI/2AO/ZSI, MODBUS/DNP3 (FO LC), SM
$17,686.11$19,120.12 -
Eaton
ETR-5000-2B3LA1
ETR-5000, 8I/9O/2AI/2AO/ZSI, MODBUS/DNP3 (FO LC), PM
$17,782.50$19,224.33 -
Eaton
ETR-5000-2B3LB0
ETR-5000, 8I/9O/2AI/2AO/ZSI, MODBUS/DNP3 (FO LC), SM
$19,064.36$20,610.12 -
Eaton
ETR-5000-2B3LB1
ETR-5000, 8I/9O/2AI/2AO/ZSI, MODBUS/DNP3 (FO LC), PM
$19,151.13$20,703.92 -
Eaton
ETR-5000-2D0HA0
ETR-5000, 24I/11O, 61850/MODBU
$14,701.03$15,892.99 -
Eaton
ETR-5000-2D0HA1
ETR-5000, 24I/11O, 61850/MODBU
$14,794.38$15,993.91 -
Eaton
ETR-5000-2F0HA0
ETR-5000, 16I/16O, 61850/MODBU
$18,023.28$19,484.62 -
Eaton
ETR-5000-2F0HA1
ETR-5000, 16I/16O, 61850/MODBU
$14,794.38$15,993.91 -
Noark
Ex9RCA13B
Safety Contactor Relay (24 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13DAS
Safety Control Relay (12 Vdc, 1NO+3NC aux. contacts)
$73.01$81.12 -
Noark
Ex9RCA13DBS
Safety Control Relay (24 Vdc, 1NO+3NC aux. contacts)
$73.01$81.12 -
Noark
Ex9RCA13DES
Safety Control Relay (48 Vdc, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13DGS
Safety Control Relay (120 Vdc, 1NO+3NC aux. contacts)
$73.01$81.12 -
Noark
Ex9RCA13E
Safety Control Relay (48 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13G
Safety Control Relay (120 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13T
Safety Control Relay (480 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13U
Safety Control Relay (240 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA13X
Safety Control Relay (208 Vac, 1NO+3NC aux. contacts)
$82.73 -
Noark
Ex9RCA22B
Safety Control Relay (24 Vac, 2NO+2NC aux. contacts)
$82.73 -
Noark
Ex9RCA22DAS
Safety Control Relay (12 Vdc, 2NO+2NC aux. contacts)
$82.73 -
Noark
Ex9RCA22DBS
Safety Control Relay (24 Vdc, 2NO+2NC aux. contacts)
$73.01$81.12 -
Noark
Ex9RCA22DES
Safety Control Relay (48 Vdc, 2NO+2NC aux. contacts)
$82.73 -
Noark
Ex9RCA22DGS
Safety Control Relay (120 Vdc, 2NO+2NC aux. contacts)
$82.73 -
Noark
Ex9RCA22E
Safety Control Relay (48 Vac, 2NO+2NC aux. contacts)
$82.73
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.