Eaton
1000TPHSR431M
Autovar 1000 Kvar 480V Nema1 Breaker
$67,373.34$76,998.10 -
Eaton
1000TPHSR431MW
Autovar 1000 Kvar 480V Nema 3R Breaker
$71,177.69$81,345.92 -
Eaton
1000TPHSR431W
Autovar 600, 480 V, 400 Kvar, 60 Hz, Nema 3R
$60,572.13$69,225.27 -
Eaton
1000TPHSR631
Autovar 600, 480 V, 400 Kvar, 60 Hz, Nema 1
$51,531.79$58,893.48 -
Eaton
1000TPHSR631M
Autovar 1000 Kvar 600V Nema 1 Breaker
$66,179.49$75,633.70 -
Eaton
1000TPHSR631MW
Autovar 1000 Kvar 600V Nema 3R Breaker
$69,983.84$79,981.52 -
Eaton
1000TPHSR631W
Autovar 600, 480 V, 400 Kvar, 60 Hz, Nema 3R
$55,336.14$63,241.30 -
Eaton
100232HMURF
Fixed Filter, 100 Kvar 240V 3Ph
$17,821.08$20,366.95 -
Eaton
100232HMURFY
Fixed Detuned Filter, 100 Kvar 240V 3Ph 60 Hz 4.2H
$18,866.65$21,561.88 -
Eaton
10023HURF
Unipak Hd 100 Kvar 240V Nema 1
$5,081.51$5,807.43 -
Eaton
10023PMURF
Fixed Capacitor, 100 Kvar 240V 3Ph W/Lts & Fuses
$4,547.81$5,197.50 -
Eaton
100243MVF3
100 Kvar 2400V 3Ph Fixed 3 Fuses
$3,616.19$4,132.78 -
Eaton
100243MVF3C
100 Kvar 2400V 3Ph Fixed 3 Fuses Csa
$3,616.19$4,132.78 -
Eaton
100413MVF3
100 Kvar 4160V 3Ph Fixed 3 Fuses
$3,972.60$4,540.11 -
Eaton
100413MVF3C
100 Kvar 4160V 3Ph Fixed 3 Fuses Csa
$3,303.84$3,775.80 -
Eaton
100432HMURF
Fixed Filter, 100 Kvar 480V 3Ph
$15,259.00$17,438.86 -
Eaton
100432HMURFY
Fixed Detuned Filter, 100 Kvar 480V 3Ph 60 Hz 4.2H
$14,343.06$16,392.07 -
Eaton
10043HURF
Fixed Harm Cap, 100 Kvar 480V 3Ph W/Lts & Fuses
$3,388.24$3,872.27 -
Eaton
10043HURN
Fixed Harm Cap, 100 Kvar 480V 3Ph
$2,704.88 -
Eaton
10043PMURN
Fixed Capacitor, 100 Kvar 480V 3Ph
$1,474.79$1,685.47 -
Eaton
100MCSR231
Wall Mtd, Switched Cap Bank, 240V, 100 Kvar
$15,957.90$18,237.60 -
Eaton
100MCSR231M
Wall Mtd, Switched Cap Bank, 240V, 100 Kvar 400 Cb
$20,062.39$22,928.45 -
Eaton
100MCSR231MW
Wall Mtd, Switched Cap Bank, 240V, 100 Kvar 400 Cb & 3R
$21,914.41$25,045.05 -
Eaton
100MCSR231W
Wall Mtd, Switched Cap Bank, 240V, 100 Kvar 3R
$17,989.68$20,559.63 -
Eaton
100MCSR4313
Wall Mtd, Switched Cap Bank, 480V, 100 Kvar
$14,740.56$16,846.35 -
Eaton
100MCSR4313M
Wall Mtd, Switched Cap Bank, 480V, 100 Kvar 250 Cb
$19,596.81$22,396.35 -
Eaton
100MCSR4313MW
Wall Mtd, Switched Cap Bank, 480V, 100 Kvar 250 Cb & 3R
$22,863.13$26,129.28 -
Eaton
100MCSR4313W
Wall Mtd, Switched Cap Bank, 480V, 100 Kvar 3R
$18,354.66$20,976.75
Capacitors & Power Factor Correction
Inductive loads like motors, drives, and transformers draw reactive power from your electrical system, increasing total current draw and potentially triggering utility power factor penalties. Power factor correction capacitors offset that reactive power locally, reducing current draw and freeing up system capacity. Depending on your system, that might mean individual units at a specific load, or grouped units automatically switching banks across a distribution system. The right configuration depends on how much reactive power needs correction and how your system is arranged. Wistex supplies power factor correction capacitors and capacitor banks for industrial applications, sized to your voltage, phase, kVAR rating, termination style, and enclosure requirements.
What to Consider When Selecting Power Factor Correction Capacitors
Start with the electrical characteristics of the system you’re correcting. Voltage and phase need to match the application, and the kVAR rating must align with the reactive power you need to compensate for. Size against actual load conditions rather than nameplate assumptions; sizing too aggressively or too lightly reduces effectiveness. Installation matters just as much. Termination style, mounting method, fusible protection, and NEMA enclosure rating all affect whether the capacitor suits your environment, especially in dusty, moist, or harsh conditions.
Correction Methods
Individual Fixed Correction
Capacitors are installed directly at individual pieces of equipment, such as large motors, and switch on and off with that equipment. This corrects power factor at the point where the reactive load is created.Group Correction
A bank of capacitors is connected to a distribution board serving several smaller motors or loads. This suits installations where individual correction at each load would be impractical or uneconomic.
Automatic Switched Capacitor Banks
Installed at the main switchboard, these systems use a controller to monitor facility power factor and automatically connect or disconnect capacitor steps as load changes through the day. This suits plants where load varies significantly across a shift.
Capacitors and Harmonic Distortion
Facilities with a high percentage of non-linear loads, such as variable frequency drives (VFDs) or LED drivers, can run into trouble with standard power factor correction capacitors, which may resonate with system harmonics and fail prematurely. In these environments, detuned capacitor banks pair the capacitor with a reactor tuned below the dominant harmonic frequency to prevent resonance while still delivering reactive power compensation. Wistex supplies capacitors, line reactors, and harmonic filters, and can help you match the right combination to your harmonic environment if your facility runs significant VFD load. Complete your power quality setup with line reactors and harmonic filters for detuned and harmonic-sensitive applications.
Frequently Asked Questions
A power factor correction capacitor supplies leading reactive power to offset the lagging reactive power drawn by inductive loads such as motors and transformers. This aligns the current and voltage waveforms more closely, reduces total current drawn from the supply, and improves the efficiency of the electrical system.
Start by matching the capacitor to the system voltage, phase, and required kVAR rating. Then determine whether correction should be applied at an individual load or across a distribution system, and confirm the mounting method, termination style, and enclosure rating suit the installation environment.
An individual capacitor bank is used when power factor correction is needed close to a specific load, such as a large motor. This corrects the power factor at the source of the reactive demand rather than across a broader section of the electrical system.
Standard capacitors can resonate with the harmonics that VFDs produce and may fail as a result. Facilities with significant VFD load require detuned capacitor banks, which pair the capacitor with a reactor to prevent resonance while still correcting power factor.