Capacitors & Power Factor Correction

Inductive loads like motors, drives, and transformers draw reactive power from your electrical system, increasing total current draw and potentially triggering utility power factor penalties. Power factor correction capacitors offset that reactive power locally, reducing current draw and freeing up system capacity. Depending on your system, that might mean individual units at a specific load, or grouped units automatically switching banks across a distribution system. The right configuration depends on how much reactive power needs correction and how your system is arranged. Wistex supplies power factor correction capacitors and capacitor banks for industrial applications, sized to your voltage, phase, kVAR rating, termination style, and enclosure requirements.

  • 12X63PMURF | Eaton Fixed Capacitor, 12.5 Kvar 600V 3Ph W/Lts & Fuses
    Eaton

    12X63PMURF

    Fixed Capacitor, 12.5 Kvar 600V 3Ph W/Lts & Fuses

    $559.55
    $639.49
  • 12X63PMURN | Eaton Fixed Capacitor, 12.5 Kvar 600V 3Ph
    Eaton

    12X63PMURN

    Fixed Capacitor, 12.5 Kvar 600V 3Ph

    $511.10
    $584.12
  • 1313MV2AI38FGMW | Eaton 1313Kvar,13800V,60Hz,4.2Hdetuned Filter
    Eaton

    1313MV2AI38FGMW

    1313Kvar,13800V,60Hz,4.2Hdetuned Filter

    $202,647.65
    $231,597.32
  • 14023PMURF | Eaton Fixed Capacitor, 140 Kvar 240V 3Ph W/Lts & Fuses
    Eaton

    14023PMURF

    Fixed Capacitor, 140 Kvar 240V 3Ph W/Lts & Fuses

    $5,468.10
    $6,249.26
  • 14043PMURF | Eaton Fixed Capacitor, 140 Kvar 480V 3Ph W/Lts & Fuses
    Eaton

    14043PMURF

    Fixed Capacitor, 140 Kvar 480V 3Ph W/Lts & Fuses

    $3,575.75
    $4,086.57
  • 14063PMURF | Eaton Fixed Capacitor, 140 Kvar 600V 3Ph W/Lts & Fuses
    Eaton

    14063PMURF

    Fixed Capacitor, 140 Kvar 600V 3Ph W/Lts & Fuses

    $3,235.80
    $3,698.06
  • 14S63PHRMB | Eaton 14.7 Kvar 600V 3Ph Cylindrical Capacitor Cell Heavy Duty
    Eaton

    14S63PHRMB

    14.7 Kvar 600V 3Ph Cylindrical Capacitor Cell Heavy Duty

    $693.65
  • 150232HMURF | Eaton Fixed Filter, 150 Kvar 240V 3Ph
    Eaton

    150232HMURF

    Fixed Filter, 150 Kvar 240V 3Ph

    $19,601.13
    $22,401.29
  • 150232HMURFY | Eaton Fixed Detuned Filter, 150 Kvar 240V 3Ph 60 Hz 4.2H
    Eaton

    150232HMURFY

    Fixed Detuned Filter, 150 Kvar 240V 3Ph 60 Hz 4.2H

    $19,529.43
  • 15023PMURF | Eaton Fixed Capacitor, 150 Kvar 240V 3Ph W/Lts & Fuses
    Eaton

    15023PMURF

    Fixed Capacitor, 150 Kvar 240V 3Ph W/Lts & Fuses

    $6,097.31
    $6,968.36
  • 150243MVF3 | Eaton 150 Kvar 2400V 3Ph Fixed 3 Fuses
    Eaton

    150243MVF3

    150 Kvar 2400V 3Ph Fixed 3 Fuses

    $4,048.80
    $4,627.21
  • 150243MVF3C | Eaton 150 Kvar 2400V 3Ph Fixed 3 Fuses Csa
    Eaton

    150243MVF3C

    150 Kvar 2400V 3Ph Fixed 3 Fuses Csa

    $4,048.80
    $4,627.21
  • 150413MVF3 | Eaton 150 Kvar 4160V 3Ph Fixed 3 Fuses
    Eaton

    150413MVF3

    150 Kvar 4160V 3Ph Fixed 3 Fuses

    $4,583.76
    $5,238.59
  • 150413MVF3C | Eaton 150 Kvar 4160V 3Ph Fixed 3 Fuses Csa
    Eaton

    150413MVF3C

    150 Kvar 4160V 3Ph Fixed 3 Fuses Csa

    $3,756.24
    $4,292.85
  • 150432HMURF | Eaton Fixed Filter, 150 Kvar 480V 3Ph
    Eaton

    150432HMURF

    Fixed Filter, 150 Kvar 480V 3Ph

    $16,457.95
    $18,809.09
  • 150432HMURFY | Eaton Fixed Detuned Filter, 150 Kvar 480V 3Ph 60 Hz 4.2H
    Eaton

    150432HMURFY

    Fixed Detuned Filter, 150 Kvar 480V 3Ph 60 Hz 4.2H

    $16,155.50
    $18,463.43
  • 15043HURF | Eaton Fixed Harm Cap, 150 Kvar 480V 3Ph W/Lts & Fuses
    Eaton

    15043HURF

    Fixed Harm Cap, 150 Kvar 480V 3Ph W/Lts & Fuses

    $4,885.51
    $5,583.45
  • 15043HURN | Eaton Fixed Harm Cap, 150 Kvar 480V 3Ph
    Eaton

    15043HURN

    Fixed Harm Cap, 150 Kvar 480V 3Ph

    $3,887.01
    $4,442.30
  • 15043PMURF | Eaton Fixed Capacitor, 150 Kvar 480V 3Ph W/Lts & Fuses
    Eaton

    15043PMURF

    Fixed Capacitor, 150 Kvar 480V 3Ph W/Lts & Fuses

    $3,294.63
  • 150483MVF3 | Eaton 150 Kvar 4800V 3Ph Fixed 3 Fuses
    Eaton

    150483MVF3

    150 Kvar 4800V 3Ph Fixed 3 Fuses

    $3,769.86
    $4,308.42
  • 150483MVF3C | Eaton 150 Kvar 4800V 3Ph Fixed 3 Fuses Csa
    Eaton

    150483MVF3C

    150 Kvar 4800V 3Ph Fixed 3 Fuses Csa

    $4,446.94
    $5,082.23
  • 150632HMURFY | Eaton Fixed Detuned Filter, 150 Kvar 600V 3Ph 60 Hz 4.2H
    Eaton

    150632HMURFY

    Fixed Detuned Filter, 150 Kvar 600V 3Ph 60 Hz 4.2H

    $17,694.68
    $20,222.48
  • 15063HURF | Eaton Fixed Harm Cap, 150 Kvar 600V 3Ph W/Lts & Fuses
    Eaton

    15063HURF

    Fixed Harm Cap, 150 Kvar 600V 3Ph W/Lts & Fuses

    $4,425.91
  • 15063PMURF | Eaton Fixed Capacitor, 150 Kvar 600V 3Ph W/Lts & Fuses
    Eaton

    15063PMURF

    Fixed Capacitor, 150 Kvar 600V 3Ph W/Lts & Fuses

    $2,948.76
  • 150MCSR431 | Eaton Wall Mtd, Switched Cap Bank, 480V, 150 Kvar
    Eaton

    150MCSR431

    Wall Mtd, Switched Cap Bank, 480V, 150 Kvar

    $15,478.79
    $17,690.04
  • 150MCSR4313 | Eaton Wall Mtd, Switched Cap Bank, 480V, 150 Kvar
    Eaton

    150MCSR4313

    Wall Mtd, Switched Cap Bank, 480V, 150 Kvar

    $18,418.60
    $21,049.83
  • 150MCSR431M | Eaton Wall Mtd, Switched Cap Bank, 480V, 150 Kvar 250 Cb
    Eaton

    150MCSR431M

    Wall Mtd, Switched Cap Bank, 480V, 150 Kvar 250 Cb

    $20,303.23
    $23,203.67
  • 150MCSR431MW | Eaton Wall Mtd, Switched Cap Bank, 480V, 150 Kvar 250 Cb & 3R
    Eaton

    150MCSR431MW

    Wall Mtd, Switched Cap Bank, 480V, 150 Kvar 250 Cb & 3R

    $24,040.46
    $27,474.82

What to Consider When Selecting Power Factor Correction Capacitors

Start with the electrical characteristics of the system you’re correcting. Voltage and phase need to match the application, and the kVAR rating must align with the reactive power you need to compensate for. Size against actual load conditions rather than nameplate assumptions; sizing too aggressively or too lightly reduces effectiveness. Installation matters just as much. Termination style, mounting method, fusible protection, and NEMA enclosure rating all affect whether the capacitor suits your environment, especially in dusty, moist, or harsh conditions.

Correction Methods

Individual Fixed Correction

Capacitors are installed directly at individual pieces of equipment, such as large motors, and switch on and off with that equipment. This corrects power factor at the point where the reactive load is created.

Group Correction

A bank of capacitors is connected to a distribution board serving several smaller motors or loads. This suits installations where individual correction at each load would be impractical or uneconomic.

Automatic Switched Capacitor Banks

Installed at the main switchboard, these systems use a controller to monitor facility power factor and automatically connect or disconnect capacitor steps as load changes through the day. This suits plants where load varies significantly across a shift.

Capacitors and Harmonic Distortion

Facilities with a high percentage of non-linear loads, such as variable frequency drives (VFDs) or LED drivers, can run into trouble with standard power factor correction capacitors, which may resonate with system harmonics and fail prematurely. In these environments, detuned capacitor banks pair the capacitor with a reactor tuned below the dominant harmonic frequency to prevent resonance while still delivering reactive power compensation. Wistex supplies capacitors, line reactors, and harmonic filters, and can help you match the right combination to your harmonic environment if your facility runs significant VFD load. Complete your power quality setup with line reactors and harmonic filters for detuned and harmonic-sensitive applications.

Frequently Asked Questions

A power factor correction capacitor supplies leading reactive power to offset the lagging reactive power drawn by inductive loads such as motors and transformers. This aligns the current and voltage waveforms more closely, reduces total current drawn from the supply, and improves the efficiency of the electrical system.

Start by matching the capacitor to the system voltage, phase, and required kVAR rating. Then determine whether correction should be applied at an individual load or across a distribution system, and confirm the mounting method, termination style, and enclosure rating suit the installation environment.

An individual capacitor bank is used when power factor correction is needed close to a specific load, such as a large motor. This corrects the power factor at the source of the reactive demand rather than across a broader section of the electrical system.

Standard capacitors can resonate with the harmonics that VFDs produce and may fail as a result. Facilities with significant VFD load require detuned capacitor banks, which pair the capacitor with a reactor to prevent resonance while still correcting power factor.