Capacitors & Power Factor Correction

Inductive loads like motors, drives, and transformers draw reactive power from your electrical system, increasing total current draw and potentially triggering utility power factor penalties. Power factor correction capacitors offset that reactive power locally, reducing current draw and freeing up system capacity. Depending on your system, that might mean individual units at a specific load, or grouped units automatically switching banks across a distribution system. The right configuration depends on how much reactive power needs correction and how your system is arranged. Wistex supplies power factor correction capacitors and capacitor banks for industrial applications, sized to your voltage, phase, kVAR rating, termination style, and enclosure requirements.

  • UCWT5V57 L16 | Capacitive Unit
    Weg

    UCWT5V57 L16

    Capacitive Unit

    $56.24
    $80.00
  • 12X43PCDMF | Eaton Low Voltage Pcdm Capacitor Cell, 480 Vac, 12.5 Kvar
    Eaton

    12X43PCDMF

    Low Voltage Pcdm Capacitor Cell, 480 Vac, 12.5 Kvar

    $281.05
  • UCWT3V29 L16 | Capacitive Unit
    Weg

    UCWT3V29 L16

    Capacitive Unit

    $53.43
    $76.00
  • 1000PBPR20 | Eaton Type Pb Tri-Pac Current Limiter (One Per Pole Required)
    Eaton

    1000PBPR20

    Type Pb Tri-Pac Current Limiter (One Per Pole Required)

    $3,062.44
    $5,104.05
  • 1000THFSR432 | Eaton Switched Harmonic Filter, 480V, 1000 Kvar, 4.7H, 60 Hz
    Eaton

    1000THFSR432

    Switched Harmonic Filter, 480V, 1000 Kvar, 4.7H, 60 Hz

    $92,775.68
  • 1000THFSR432M | Eaton Autovar Filter, 4.7H, 480V, 1000 Kvar, Nema 1, Main Breaker
    Eaton

    1000THFSR432M

    Autovar Filter, 4.7H, 480V, 1000 Kvar, Nema 1, Main Breaker

    $110,180.58
    $125,920.65
  • 1000THFSR432MW | Eaton Autovar Filter, 4.7H, 480V, 1000 Kvar, Nema 3R, Main Breaker
    Eaton

    1000THFSR432MW

    Autovar Filter, 4.7H, 480V, 1000 Kvar, Nema 3R, Main Breaker

    $117,789.26
    $134,616.30
  • 1000THFSR432MWY | Eaton Autovar Filter, 4.2H, 480V, 1000 Kvar, Nema 3R, Main Breaker
    Eaton

    1000THFSR432MWY

    Autovar Filter, 4.2H, 480V, 1000 Kvar, Nema 3R, Main Breaker

    $117,184.38
    $133,925.00
  • 1000THFSR432MY | Eaton Autovar Filter, 4.2H, 480V, 1000 Kvar, Nema 1, Main Breaker
    Eaton

    1000THFSR432MY

    Autovar Filter, 4.2H, 480V, 1000 Kvar, Nema 1, Main Breaker

    $124,442.91
    $142,220.47
  • 1000THFSR432WY | Eaton Autovar, 480V, 1000 Kvar, 60Hz, 4.2H, Nema 3R
    Eaton

    1000THFSR432WY

    Autovar, 480V, 1000 Kvar, 60Hz, 4.2H, Nema 3R

    $113,317.56
    $129,505.79
  • 1000THFSR432Y | Eaton Autovar, 480V, 1000 Kvar, 4.2H, 60 Hz
    Eaton

    1000THFSR432Y

    Autovar, 480V, 1000 Kvar, 4.2H, 60 Hz

    $104,676.53
    $119,630.32
  • 1000THFSR632 | Eaton Floor Mounted, Switched Harmonic Filter, 600V, 1000 Kvar
    Eaton

    1000THFSR632

    Floor Mounted, Switched Harmonic Filter, 600V, 1000 Kvar

    $92,910.74
  • 1000THFSR632M | Eaton Autovar Filter, 4.7H, 600V, 1000 Kvar, Nema 1, Main Breaker
    Eaton

    1000THFSR632M

    Autovar Filter, 4.7H, 600V, 1000 Kvar, Nema 1, Main Breaker

    $108,128.13
    $123,575.00
  • 1000THFSR632MW | Eaton Autovar Filter, 4.7H, 600V, 1000 Kvar, Nema 3R, Main Breaker
    Eaton

    1000THFSR632MW

    Autovar Filter, 4.7H, 600V, 1000 Kvar, Nema 3R, Main Breaker

    $115,736.83
    $132,270.65
  • 1000THFSR632MWY | Eaton Autovar Filter, 4.2H, 600V, 1000 Kvar, Nema 3R, Main Breaker
    Eaton

    1000THFSR632MWY

    Autovar Filter, 4.2H, 600V, 1000 Kvar, Nema 3R, Main Breaker

    $114,996.88
    $131,425.00
  • 1000THFSR632MY | Eaton Autovar Filter, 4.2H, 600V, 1000 Kvar, Nema 1, Main Breaker
    Eaton

    1000THFSR632MY

    Autovar Filter, 4.2H, 600V, 1000 Kvar, Nema 1, Main Breaker

    $107,388.18
    $122,729.35
  • 1000THFSR632WY | Eaton Autovar, 600V, 1000 Kvar, 60Hz, 4.2H, Nema 3R
    Eaton

    1000THFSR632WY

    Autovar, 600V, 1000 Kvar, 60Hz, 4.2H, Nema 3R

    $99,779.49
    $114,033.70
  • 1000THFSR632Y | Eaton Autovar, 600V, 1000 Kvar, 4.2H, 60 Hz
    Eaton

    1000THFSR632Y

    Autovar, 600V, 1000 Kvar, 4.2H, 60 Hz

    $104,676.53
    $119,630.32
  • 1000TPCSR431 | Eaton Floor Mounted, Switched Capacitor Bank, 480V, 1000 Kvar
    Eaton

    1000TPCSR431

    Floor Mounted, Switched Capacitor Bank, 480V, 1000 Kvar

    $47,630.48
    $54,434.84
  • 1000TPCSR431M | Eaton Autovar, 1000 Kvar, 480V, Nema1, Main Breaker
    Eaton

    1000TPCSR431M

    Autovar, 1000 Kvar, 480V, Nema1, Main Breaker

    $61,431.35
    $70,207.25
  • 1000TPCSR631 | Eaton Auto Cap Bank, Flr Mtd, 600V, 1000 Kvar
    Eaton

    1000TPCSR631

    Auto Cap Bank, Flr Mtd, 600V, 1000 Kvar

    $46,648.41
    $53,312.47
  • 1000TPCSR631M | Eaton Autovar, 1000 Kvar, 600V, Nema 1, Main Breaker
    Eaton

    1000TPCSR631M

    Autovar, 1000 Kvar, 600V, Nema 1, Main Breaker

    $59,610.25
    $68,125.99
  • 1000TPHSR431 | Eaton Autovar 600, 480 V, 400 Kvar, 60 Hz, Nema 1
    Eaton

    1000TPHSR431

    Autovar 600, 480 V, 400 Kvar, 60 Hz, Nema 1

    $56,767.78

What to Consider When Selecting Power Factor Correction Capacitors

Start with the electrical characteristics of the system you’re correcting. Voltage and phase need to match the application, and the kVAR rating must align with the reactive power you need to compensate for. Size against actual load conditions rather than nameplate assumptions; sizing too aggressively or too lightly reduces effectiveness. Installation matters just as much. Termination style, mounting method, fusible protection, and NEMA enclosure rating all affect whether the capacitor suits your environment, especially in dusty, moist, or harsh conditions.

Correction Methods

Individual Fixed Correction

Capacitors are installed directly at individual pieces of equipment, such as large motors, and switch on and off with that equipment. This corrects power factor at the point where the reactive load is created.

Group Correction

A bank of capacitors is connected to a distribution board serving several smaller motors or loads. This suits installations where individual correction at each load would be impractical or uneconomic.

Automatic Switched Capacitor Banks

Installed at the main switchboard, these systems use a controller to monitor facility power factor and automatically connect or disconnect capacitor steps as load changes through the day. This suits plants where load varies significantly across a shift.

Capacitors and Harmonic Distortion

Facilities with a high percentage of non-linear loads, such as variable frequency drives (VFDs) or LED drivers, can run into trouble with standard power factor correction capacitors, which may resonate with system harmonics and fail prematurely. In these environments, detuned capacitor banks pair the capacitor with a reactor tuned below the dominant harmonic frequency to prevent resonance while still delivering reactive power compensation. Wistex supplies capacitors, line reactors, and harmonic filters, and can help you match the right combination to your harmonic environment if your facility runs significant VFD load. Complete your power quality setup with line reactors and harmonic filters for detuned and harmonic-sensitive applications.

Frequently Asked Questions

A power factor correction capacitor supplies leading reactive power to offset the lagging reactive power drawn by inductive loads such as motors and transformers. This aligns the current and voltage waveforms more closely, reduces total current drawn from the supply, and improves the efficiency of the electrical system.

Start by matching the capacitor to the system voltage, phase, and required kVAR rating. Then determine whether correction should be applied at an individual load or across a distribution system, and confirm the mounting method, termination style, and enclosure rating suit the installation environment.

An individual capacitor bank is used when power factor correction is needed close to a specific load, such as a large motor. This corrects the power factor at the source of the reactive demand rather than across a broader section of the electrical system.

Standard capacitors can resonate with the harmonics that VFDs produce and may fail as a result. Facilities with significant VFD load require detuned capacitor banks, which pair the capacitor with a reactor to prevent resonance while still correcting power factor.