Electrical Relays

  • 1SVR405618R2100 | ABB Cr-M120Ac4Lg Pluggable Relay
    ABB

    1SVR405618R2100

    Cr-M120Ac4Lg Pluggable Relay

    $22.81
    $35.27
  • 1SVR730030R3300 | ABB Ct-Mxs.22S Multifunction Timer
    ABB

    1SVR730030R3300

    Ct-Mxs.22S Multifunction Timer

    $159.27
    $254.31
  • 1SVR730830R0400 | ABB Cm-Ess.2S Voltage Mon. Relay
    ABB

    1SVR730830R0400

    Cm-Ess.2S Voltage Mon. Relay

    $269.73
    $398.41
  • 232-INSIDER Littelfuse 1-Phase Pumpsaver/ 230V/ For G
    Littelfuse

    232-INSIDER

    1-Phase Pumpsaver/ 230V/ For G

    $528.53
  • EMR-3MP0-ADAPTER | Eaton EMR TERMINAL ADAPTER FOR MP3000 RETROFIT
    Eaton

    EMR-3MP0-ADAPTER

    EMR TERMINAL ADAPTER FOR MP3000 RETROFIT

    $1,047.18
    $1,132.09
  • LLC843F26M Littelfuse Liquid Level Control
    Littelfuse

    LLC843F26M

    Liquid Level Control

    $230.91
  • TUB-115V-2 RK Electronics Univ Timer 115VAC/VDC .1S to 72M 11-Pin
    RK Electronics

    TUB-115V-2

    Univ Timer 115VAC/VDC .1S to 72M 11-Pin

    $122.54
    $150.00
  • 1SVR550826R9100 | ABB Cm-Pfe.2 Phase Seq. Monitoring Rel.
    ABB

    1SVR550826R9100

    Cm-Pfe.2 Phase Seq. Monitoring Rel.

    $59.95
    $88.56
  • 1SVR730850R0100 | ABB Cm-Ens.11S Liq. Lvl Mon. Rel.
    ABB

    1SVR730850R0100

    Cm-Ens.11S Liq. Lvl Mon. Rel.

    $118.93
    $175.67
  • EMR-3MP0-2A0HB1 | Eaton EMR-3MP0, 4I/4O, 1AO, 61850/MODBUS/DNP3
    Eaton

    EMR-3MP0-2A0HB1

    EMR-3MP0, 4I/4O, 1AO, 61850/MODBUS/DNP3

    $7,197.80
    $7,781.40
  • EMR-3MP0-2A9BB1-1 | Eaton EMR-3MP0, 4I/4O, 1AO, MODBUS/DNP3 (RS485
    Eaton

    EMR-3MP0-2A9BB1-1

    EMR-3MP0, 4I/4O, 1AO, MODBUS/DNP3 (RS485

    $6,519.26
    $7,047.86
  • ISS-100
    Littelfuse

    ISS-100

    Single-Channel Intrinsically Safe Relay

    $417.49
  • ISS-101
    Littelfuse

    ISS-101

    Single-Channel Intrinsically Safe Relay

    $417.49
  • LPC-120-AAA ATC Liquid Level Pump Controller
    ATC

    LPC-120-AAA

    Liquid Level Pump Controller

    $132.79
    $156.83
  • P1004-10 Littelfuse Potentiometer 1 Meg 10% (P1)
    Littelfuse

    P1004-10

    Potentiometer 1 Meg 10% (P1)

  • PGR-4300-24 Littelfuse Generator Ground Fault Relay (24VDC Supply)
    Littelfuse

    PGR-4300-24

    Generator Ground Fault Relay (24VDC Supply)

    $4,865.42
  • PLS480A Littelfuse Reverse Phase Relay
    Littelfuse

    PLS480A

    Reverse Phase Relay

    $268.33
  • PVC-400-AR RK Electronics Voltage Monitor and Protection Relay (Three-phase, 440-480AC, 600VAC Output)
    RK Electronics

    PVC-400-AR

    Voltage Monitor and Protection Relay (Three-phase, 440-480AC, 600VAC Output)

    $308.00
    $310.00
  • TDH-120-AKB-30M ATC Delayed Interval Time Delay Relay 110/120 V AC/DC
    ATC

    TDH-120-AKB-30M

    Delayed Interval Time Delay Relay 110/120 V AC/DC

    $253.89
    $281.05

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.