Electrical Relays

  • 1SVR508120R0000 ABB Dual-Function Electronic Time Relay (1 c/o, 24-48VDC / 24-240VAC)
    ABB

    1SVR508120R0000

    Dual-Function Electronic Time Relay (1 c/o, 24-48VDC / 24-240VAC)

    $139.73
    $184.65
  • 1SVR550127R4100 | ABB Ct-Are Time Relay True Off-Delay
    ABB

    1SVR550127R4100

    Ct-Are Time Relay True Off-Delay

    $82.78
    $222.13
  • 460 Littelfuse 3-Phase Volt Mon/ 190-480V/ Ad
    Littelfuse

    460

    3-Phase Volt Mon/ 190-480V/ Ad

    $163.04
    $228.64
  • D5RF3T1 Eaton General Purpose Ice Cube Relay (3PDT, 10A, 24VDC Coil)
    Eaton

    D5RF3T1

    General Purpose Ice Cube Relay (3PDT, 10A, 24VDC Coil)

    $41.62
    $56.24
  • TUC-120-AKA-015 ATC On-Delay Time Delay Relay 110/120V AC/DC
    ATC

    TUC-120-AKA-015

    On-Delay Time Delay Relay 110/120V AC/DC

    $189.10
    $223.34
  • 1SVR730712R1400 | ABB Thermistor Motor Protection Relay (1NO & 1NC, 24 - 240 V AC/DC)
    ABB

    1SVR730712R1400

    Thermistor Motor Protection Relay (1NO & 1NC, 24 - 240 V AC/DC)

    $207.02
    $330.54
  • 235P Littelfuse 1-Phase Pumpsaverplus/230V/5-1
    Littelfuse

    235P

    1-Phase Pumpsaverplus/230V/5-1

    $736.69
  • 777-KW/HP-P2 Littelfuse 3-Phase Power Monitor/200-480V
    Littelfuse

    777-KW/HP-P2

    3-Phase Power Monitor/200-480V

    $1,931.66
  • CT-0050-D10 Littelfuse Ct 50:5 1" Window Donut
    Littelfuse

    CT-0050-D10

    Ct 50:5 1" Window Donut

    $170.07
  • D3PA6 Eaton D3 Series Socket Used with D3PR2 and D3PF2 Relays (Module size A, 300V nominal voltage, 16A nominal current)
    Eaton

    D3PA6

    D3 Series Socket Used with D3PR2 and D3PF2 Relays (Module size A, 300V nominal voltage, 16A nominal current)

    $12.45
    $23.90
  • PHS230A20 Littelfuse Ac Phase Control
    Littelfuse

    PHS230A20

    Ac Phase Control

    $147.60
  • STR-120A-B RK Electronics Digital Seal & TempStat Relay, 120VAC, 1 or 2-Input Monitoring, Adjustable 5K to 200K Ohms Seal Trip, 2 SPDT Output Contacts, Pluggable Termial Blocks, Surface Mount
    RK Electronics

    STR-120A-B

    Digital Seal & TempStat Relay, 120VAC, 1 or 2-Input Monitoring, Adjustable 5K to 200K Ohms Seal Trip, 2 SPDT Output Contacts, Pluggable Termial Blocks, Surface Mount

    $199.99
    $200.00
  • 15000001 B/W Controls Contact Assembly Kit for 1500 Series
    B/W Controls

    15000001

    Contact Assembly Kit for 1500 Series

    $30.81
    $31.12
  • 1SVR730005R0100 | ABB Cov.11 Sealable Transparent Cover
    ABB

    1SVR730005R0100

    Cov.11 Sealable Transparent Cover

    $21.50
    $31.75
  • 5200-LF1-N4X B/W Controls Solid State Relays
    B/W Controls

    5200-LF1-N4X

    Solid State Relays

    $893.97
    $903.00
  • 5200-LV1-OC B/W Controls Level Control Relay
    B/W Controls

    5200-LV1-OC

    Level Control Relay

    $727.65
    $735.00
  • 777-LR-P2 Littelfuse 3-Phase Overload Relay/200-480
    Littelfuse

    777-LR-P2

    3-Phase Overload Relay/200-480

    $1,844.99
  • OL-RESET Littelfuse Reset Module For Model 777
    Littelfuse

    OL-RESET

    Reset Module For Model 777

    $146.40

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.