Electrical Relays

  • SPM-120-ABA-100K ATC Dual Channel Seal Failure Alarm
    ATC

    SPM-120-ABA-100K

    Dual Channel Seal Failure Alarm

    $153.79
    $181.63
  • SPM-120-ABA-25K ATC Dual Channel Seal Failure Alarm
    ATC

    SPM-120-ABA-25K

    Dual Channel Seal Failure Alarm

    $255.36
    $301.58
  • SPM-120-ACA Non-Volatile Latching Temperature Switch Relay
    ATC

    SPM-120-ACA

    Non-Volatile Latching Temperature Switch Relay

    $240.90
    $284.51
  • SPM-120-ADA Non-Volite Latching Temperature Switch Relay
    ATC

    SPM-120-ADA

    Non-Volite Latching Temperature Switch Relay

    $209.29
    $247.17
  • SPM-120-AEA-100K ATC Dual Function Plug-In Seal Failure Temp Switch Relay
    ATC

    SPM-120-AEA-100K

    Dual Function Plug-In Seal Failure Temp Switch Relay

    $587.80
    $694.21
  • SPM-120-AEA-25K ATC Dual Function Plug-In Seal Failure Temp Switch Relay
    ATC

    SPM-120-AEA-25K

    Dual Function Plug-In Seal Failure Temp Switch Relay

    $616.71
    $728.35
  • SPM-120-AEAS-100K ATC Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel
    ATC

    SPM-120-AEAS-100K

    Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel

    $597.44
    $705.59
  • SPM-120-AEAS-25K ATC Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel
    ATC

    SPM-120-AEAS-25K

    Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel

    $568.53
    $671.45
  • SPM-120-AEE ATC Dual Function Simplex Alarm / Relay Surface Mount
    ATC

    SPM-120-AEE

    Dual Function Simplex Alarm / Relay Surface Mount

    $346.90
    $409.70
  • SPM-24-AEA-100K ATC Dual Function Plug-In Seal Failure Temp Switch Relay
    ATC

    SPM-24-AEA-100K

    Dual Function Plug-In Seal Failure Temp Switch Relay

    $611.89
    $722.66
  • SPM-24-AEA-25K ATC Dual Function Plug-In Seal Failure Temp Switch Relay
    ATC

    SPM-24-AEA-25K

    Dual Function Plug-In Seal Failure Temp Switch Relay

    $568.53
    $671.45
  • SPM-24-AEAS-100K ATC Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel
    ATC

    SPM-24-AEAS-100K

    Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel

    $420.70
    $496.86
  • SPM-24-AEAS-25K ATC Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel
    ATC

    SPM-24-AEAS-25K

    Dual Func. Plug-In Seal Failure /Temp Relay, Mode Sel

    $549.26
    $648.69
  • SR3P-05 | 11-PIN DIN MOUNTED SOCKET
    RK Electronics

    SR3P-05

    11-PIN DIN MOUNTED SOCKET

    $10.59
    $12.00
  • SRW01-CB1 | Weg Connection Cable
    Weg

    SRW01-CB1

    Connection Cable

    $9.84
    $14.00
  • SRW01-CB2 | Weg Connection Cable
    Weg

    SRW01-CB2

    Connection Cable

    $11.25
    $16.00
  • SRW01-CB3 | Weg Connection Cable
    Weg

    SRW01-CB3

    Connection Cable

    $12.65
    $18.00
  • SRW01-CH1 | Weg Connection Cable Kit
    Weg

    SRW01-CH1

    Connection Cable Kit

    $24.61
    $35.00
  • SRW01-CH2 | Weg Connection Cable Kit
    Weg

    SRW01-CH2

    Connection Cable Kit

    $24.61
    $35.00
  • SRW01-CH3 | Weg Connection Cable Kit
    Weg

    SRW01-CH3

    Connection Cable Kit

    $24.61
    $35.00
  • SRW01-MCD | Weg Communication Module
    Weg

    SRW01-MCD

    Communication Module

    $70.30
    $100.00
  • SRW01-MCM | Weg Communication Module
    Weg

    SRW01-MCM

    Communication Module

    $154.66
    $220.00
  • SRW01-MCP | Weg Communication Module
    Weg

    SRW01-MCP

    Communication Module

    $281.20
    $400.00

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.