Electrical Relays

  • SE-TA6A-WL Littelfuse Gf/Gc Term Assy 5.6V 50W Tc Wl
    Littelfuse

    SE-TA6A-WL

    Gf/Gc Term Assy 5.6V 50W Tc Wl

    $1,468.01
  • SE-TA6ASF-WL Littelfuse Term Assy Small Format Wl
    Littelfuse

    SE-TA6ASF-WL

    Term Assy Small Format Wl

    $1,401.28
  • SE-VS1002K Littelfuse Ngr Voltage Scaler 100-2Kv
    Littelfuse

    SE-VS1002K

    Ngr Voltage Scaler 100-2Kv

    $711.49
  • SE-VS50010K Littelfuse Ngr Voltage Scaler 500-10Kv
    Littelfuse

    SE-VS50010K

    Ngr Voltage Scaler 500-10Kv

    $711.49
  • SG-14B RK Electronics Socket, Ice Cube, 14-Blade, Din Mount
    RK Electronics

    SG-14B

    Socket, Ice Cube, 14-Blade, Din Mount

    $5.88
    $10.00
  • SIO-RTD-02-00 Littelfuse Rtd Module 1'C Accuracy
    Littelfuse

    SIO-RTD-02-00

    Rtd Module 1'C Accuracy

    $4,771.87
  • SIR1B6B4 Littelfuse Solid State Relay
    Littelfuse

    SIR1B6B4

    Solid State Relay

    $155.46
  • SIR2A20A4 Littelfuse Solid State Relay-Isolated
    Littelfuse

    SIR2A20A4

    Solid State Relay-Isolated

    $206.92
  • SIR2B20A4 Littelfuse Solid State Relay-Isolated
    Littelfuse

    SIR2B20A4

    Solid State Relay-Isolated

    $206.92
  • SIR2B20B4 Littelfuse Solid State Relay-Isolated
    Littelfuse

    SIR2B20B4

    Solid State Relay-Isolated

    $206.92
  • SLA-0246B ATC Phase Sequence Loss Monitor
    ATC

    SLA-0246B

    Phase Sequence Loss Monitor

    $578.17
    $682.83
  • SLA-120-ALA ATC Phase Monitor/Relay
    ATC

    SLA-120-ALA

    Phase Monitor/Relay

    $520.00
    $643.00
  • SLA-120-ALE ATC Phase Monitor/Relay
    ATC

    SLA-120-ALE

    Phase Monitor/Relay

    $544.44
    $643.00
  • SLA-120-ALER ATC Phase Monitor/Relay
    ATC

    SLA-120-ALER

    Phase Monitor/Relay

    $423.89
    $500.63
  • SLA-120-ASA ATC Phase Monitor/Relay
    ATC

    SLA-120-ASA

    Phase Monitor/Relay

    $240.90
    $284.51
  • SLA-208-AFA ATC Phase Monitor/Relay
    ATC

    SLA-208-AFA

    Phase Monitor/Relay

    $563.06
    $664.99
  • SLA-208-AFE ATC Phase Monitor/Relay
    ATC

    SLA-208-AFE

    Phase Monitor/Relay

    $414.33
    $489.34
  • SLA-208-AFN ATC Phase Monitor/Relay
    ATC

    SLA-208-AFN

    Phase Monitor/Relay

    $361.21
    $426.60
  • SLA-230-AFA ATC Phase Monitor/Relay
    ATC

    SLA-230-AFA

    Phase Monitor/Relay

    $520.35
    $614.54
  • SLA-230-ALA ATC Phase Monitor/Relay
    ATC

    SLA-230-ALA

    Phase Monitor/Relay

    $164.67
    $194.48
  • SLA-230-ALER ATC Phase Monitor/Relay
    ATC

    SLA-230-ALER

    Phase Monitor/Relay

    $664.89
    $785.25
  • SLA-380-ALE ATC Phase Monitor/Relay
    ATC

    SLA-380-ALE

    Phase Monitor/Relay

    $350.58
    $414.05
  • SLA-380-ALER ATC Phase Monitor/Relay
    ATC

    SLA-380-ALER

    Phase Monitor/Relay

    $366.52
    $432.87
  • SLA-380-ASA ATC Phase Monitor/Relay
    ATC

    SLA-380-ASA

    Phase Monitor/Relay

    $476.99
    $563.33
  • SLA-440-AFE ATC Phase Monitor/Relay
    ATC

    SLA-440-AFE

    Phase Monitor/Relay

    $472.17
    $557.64
  • SLA-440-ALE ATC Phase Monitor/Relay
    ATC

    SLA-440-ALE

    Phase Monitor/Relay

    $313.41
    $370.14
  • SLA-440-ALER ATC Phase Monitor/Relay
    ATC

    SLA-440-ALER

    Phase Monitor/Relay

    $607.08
    $716.97
  • SLA-440-ASA ATC Phase Monitor/Relay
    ATC

    SLA-440-ASA

    Phase Monitor/Relay

    $154.04
    $181.93

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.