Representative image shown

SCE-EXR18-400

External Disconnect Enclosure Rotary 400 amp

$958.25
Representative image shown
Product Details
SKU:
SCE-EXR18-400
Weight:
115.00 LBS
Width:
17.00 in
Height:
48.00 in
Depth:
18.00 in
Dimensions:
48in x 17in x 18in

Construction

Construction

SCE-EXR18-400 Saginaw Control & Engineering 48 x 17 x 18 External Disconnect Enclosure Rotary 400 Amp

  • 0.075 In. steel
  • Seams continuously welded and ground smooth.
  • Flange trough collar around all sides of door opening.
  • Pour in place oil & water resistant gasket
  • Collar studs provided for mounting panels.
  • Galvanized Subpanel installed.
  • Concealed hinges.
  • Black quarter turn latches.
  • Latches are opened or closed with a screwdriver.
  • Mounting hardware included.
  • Cable Operated Mechanical interlock and hardware included.
  • Provisions for Rotary Compact Fusible disconnect
  • For use with flange mount disconnect enclosures

Application

Application

SCE-EXR18-400 Saginaw Control & Engineering 48 x 17 x 18 External Disconnect Enclosure Rotary 400 Amp

Designed for use with enclosures that require additional protection against Arc Flash. This enclosure can be used with an environmentally rated enclosure to isolate the main power supply. It increases personal protection by preventing incidental contact or exposure to the high voltage arc flash and shock hazard, and potentially reduces the PPE level for the lower risk components of the main enclosure. This External Disconnect Enclosure is designed specifically to accommodate the Rotary Compact Fusible disconnect Allen-Bradley 194R, Square D GS2, Eaton/Bussmann R9, Siemens CFS and Scocomec Fuserbloc Models. Aids in achieving compliance with NFPA 70E by concealing main power supply.

Industry Standards

Industry Standards

SCE-EXR18-400 Saginaw Control & Engineering 48 x 17 x 18 External Disconnect Enclosure Rotary 400 Amp

  • NEMA Type 3R, 4, 12 and Type 13
  • UL Listed Type 3R, 4 and 12
  • CSA Type 3R, 4 and 12
  • IEC 60529
  • IP 66

NEMA Rating for

Nema active
N1
Indoor
Protection from fingers, tools and small objects
Nema active
N12
Indoor
Protection from dust and light splashes of water
Nema active
N3R
Outdoor
Protection from rain, snow and sleet
Nema active
N4
Outdoor
Protection from rain, snow, sleet, and hose directed water
Nema not active
N4X
Outdoor
Protected from rain, snow, sleet, and pressure rated hose directed water from all angles
N1 graphic N12 graphic N3R graphic N4 graphic N4X graphic
+
Environments Type 1 Type 12 Type 3R Type 4 Type 4X
Indoor use only
Indoor and outdoor use
Falling liquids and light splashes
Nonhazardous dust, lint, and fibers
Washdowns and splashing water
Oil and coolant seepage
Corrosive agents
Hazardous locations
(Class I, Division 1 and 2)