Electrical Transformers

Wistex offers a full range of industrial transformers engineered to improve power quality, protect sensitive equipment, and ensure safe, reliable voltage control. Whether you need to step voltage up or down, isolate circuits, or fine-tune voltage levels, our UL-listed units meet NEC standards and ship within 24 hours. To maintain OSHA lock-out/tag-out compliance during maintenance or servicing, pair your transformer with a proper disconnect switch. We stock popular kVA sizes and support you with expert guidance through every step.

  • HT20P11B7516CU | Eaton 75 KVA K4 XFMR 1PH 240X480-120/240 80C RISE COPPER

    HT20P11B7516CU

    $28,748.94
    $54,823.55
    75 KVA K4 XFMR 1PH 240X480-120/240 80C RISE COPPER
  • HT20P11F1516CU | Eaton 15 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE

    HT20P11F1516CU

    $9,798.20
    $18,684.92
    15 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE
  • HT20P11F2516 | Eaton 25 KVA K4 VENTD XFMR 1PH 240 X 480-120/240 115C RISE

    HT20P11F2516

    $8,106.66
    $15,459.21
    25 KVA K4 VENTD XFMR 1PH 240 X 480-120/240 115C RISE
  • HT20P11F7516CU | Eaton 75 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE

    HT20P11F7516CU

    $23,480.97
    $49,146.22
    75 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE
  • HT20P11F9916CU | Eaton 100 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE

    HT20P11F9916CU

    $33,692.85
    $64,251.48
    100 KVA K4 VENTD XFMR 1PH 240X480-120/240 115C RISE
  • HT20P11S1516 | Eaton 15 KVA K-4 VENT'D TRANSFORMER 1-PH 240X480-120/240

    HT20P11S1516

    $4,074.72
    $7,770.40
    15 KVA K-4 VENT'D TRANSFORMER 1-PH 240X480-120/240
  • HT20P11S1516CU | Eaton 15 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240

    HT20P11S1516CU

    $7,257.49
    $13,839.85
    15 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240
  • HT20P11S2516 | Eaton 25 KVA K4 VENTD XFMR 1PH 240X480-120/240

    HT20P11S2516

    $5,681.17
    $11,890.82
    25 KVA K4 VENTD XFMR 1PH 240X480-120/240
  • HT20P11S2516CU | Eaton 25 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240

    HT20P11S2516CU

    $8,910.90
    $18,650.73
    25 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240
  • HT20P11S25CU | Eaton 25 kVA K4 Transformer 1PH 240X480V - 120/240V 150C rise

    HT20P11S25CU

    $13,157.93
    $25,091.85
    25 kVA K4 Transformer 1PH 240X480V - 120/240V 150C rise
  • HT20P11S3716 | Eaton 37.5 KVA K4 VENTD XFMR 1PH 240X480-120/240

    HT20P11S3716

    $6,874.80
    $13,110.09
    37.5 KVA K4 VENTD XFMR 1PH 240X480-120/240
  • HT20P11S3716CU | Eaton 37.5 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240

    HT20P11S3716CU

    $10,343.40
    $21,648.97
    37.5 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240
  • HT20P11S4516 | Eaton 45 KVA K4 VENTD XFMR 1PH 240X480-120/240 150C RISE

    HT20P11S4516

    $8,022.06
    $16,790.35
    45 KVA K4 VENTD XFMR 1PH 240X480-120/240 150C RISE
  • HT20P11S5016 | Eaton 50 KVA VENTD K4 DOE2016 XFMR 1PH 240X480-120/240 150C RISE

    HT20P11S5016

    $11,937.09
    $22,763.75
    50 KVA VENTD K4 DOE2016 XFMR 1PH 240X480-120/240 150C RISE
  • HT20P11S5016CU | Eaton 50 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240

    HT20P11S5016CU

    $14,323.65
    $27,314.86
    50 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240
  • HT20P11S5016ZZ | Eaton 50 KVA K4 CORE-COIL XFMR 1PH 240X480-120/240 150C RISE

    HT20P11S5016ZZ

    $8,792.96
    $16,767.97
    50 KVA K4 CORE-COIL XFMR 1PH 240X480-120/240 150C RISE
  • HT20P11S50EE | Eaton 50 kVA K-4 Vent'd Transformer 1-PH 240X480-120/240

    HT20P11S50EE

    $8,668.97
    $21,796.26
    50 kVA K-4 Vent'd Transformer 1-PH 240X480-120/240
  • HT20P11S7516 | Eaton 75 KVA K4 VENTD XFMR 1PH 240X480-120/240

    HT20P11S7516

    $12,124.79
    $23,121.69
    75 KVA K4 VENTD XFMR 1PH 240X480-120/240
  • HT20P11S7516CU | Eaton 75 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240

    HT20P11S7516CU

    $19,829.52
    $37,814.44
    75 KVA VENTD NEMA DOE2016 XFMR, K4 1PH 240X480-120/240
  • HT20P11S99CUEE | Eaton 100 kVA Vent'd NEMA TP-1 Tx, K4 1PH 240X480-120/240

    HT20P11S99CUEE

    $23,078.60
    $58,026.20
    100 kVA Vent'd NEMA TP-1 Tx, K4 1PH 240X480-120/240
  • HT20P11S99EE | Eaton 100 kVA K-4 Vent'd Transformer 1-PH 240X480-120/240

    HT20P11S99EE

    $15,847.32
    100 kVA K-4 Vent'd Transformer 1-PH 240X480-120/240
  • HT29M11F3016 | Eaton 30 KVA K4 VENTD XFMR 1PH 208-120/240 115C RISE

    HT29M11F3016

    $10,020.89
    $20,973.96
    30 KVA K4 VENTD XFMR 1PH 208-120/240 115C RISE
  • HT29M11S2516CU | Eaton 25 KVA K4 VENTD XFMR 1PH 208-120/240 150C RISE

    HT29M11S2516CU

    $11,238.91
    $21,432.36
    25 KVA K4 VENTD XFMR 1PH 208-120/240 150C RISE
  • HT29M11S5016 | Eaton 50 KVA K4 XFMR 1PH 208-120/240 150C RISE

    HT29M11S5016

    $11,878.43
    $22,651.88
    50 KVA K4 XFMR 1PH 208-120/240 150C RISE
  • HT29R11S7516 | Eaton 75 KVA K4 VENTD XFMR 1PH 208-120/240 150C RISE

    HT29R11S7516

    $16,354.09
    $31,186.86
    75 KVA K4 VENTD XFMR 1PH 208-120/240 150C RISE
  • HT44N11S1516CU | Eaton 15 KVA K4 VENTD XFMR 1PH 440-120/240 150C RISE CU

    HT44N11S1516CU

    $5,975.10
    $12,506.02
    15 KVA K4 VENTD XFMR 1PH 440-120/240 150C RISE CU
  • HT48M11B9916 | Eaton 100 KVA K4 VENTD XFMR 1PH 480-120/240 80C RISE

    HT48M11B9916

    $26,268.08
    $54,979.70
    100 KVA K4 VENTD XFMR 1PH 480-120/240 80C RISE
  • HT48M11F2516 | Eaton 25 KVA K4 DOE2016 1PH 480-120/240 115C RISE

    HT48M11F2516

    $9,085.60
    $19,016.37
    25 KVA K4 DOE2016 1PH 480-120/240 115C RISE
  • HT48M11F6716CU | Eaton 167 KVA K4 VENTD XFMR 1PH, 480-120X240 115C RISE

    HT48M11F6716CU

    $58,561.96
    $111,676.30
    167 KVA K4 VENTD XFMR 1PH, 480-120X240 115C RISE
  • HT48M11S2516CU | Eaton 25 KVA K4 VENTD XFMR 1PH 480-120/240 150C RISE

    HT48M11S2516CU

    $11,238.91
    $21,432.36
    25 KVA K4 VENTD XFMR 1PH 480-120/240 150C RISE
  • HT48M11S3716CU | Eaton 37.5 KVA K4 VENTD XFMR 1PH 480-120/240 150C RISE

    HT48M11S3716CU

    $13,044.33
    $24,875.24
    37.5 KVA K4 VENTD XFMR 1PH 480-120/240 150C RISE
  • HT48M29S7516 | Eaton 75 KVA K4 VENTD XFMR 1PH 480-208150C RISE

    HT48M29S7516

    $16,354.09
    $31,186.86
    75 KVA K4 VENTD XFMR 1PH 480-208150C RISE

Transformer Types We Stock

Explore our most common transformer configurations, available in both dry-type and rugged enclosures for a variety of environments.

Why Choose Wistex for Transformers

Control Transformers

Designed for machine tools, relays, and panelboards, control transformers deliver stable voltage to industrial control circuits and keep sensitive equipment running smoothly.

Buck-Boost Transformers

Buck-boost transformers are an energy-efficient way to correct minor over- or under-voltage issues. These compact units offer reliable voltage adjustments for lighting, motor loads, and more without the cost of a full-size transformer.

Manual Motor Starters
Combination Starters

Isolation Transformers

Use isolation transformers to reduce electrical noise, safeguard critical devices, and prevent ground loops. Ideal for clean power applications in telecom, medical, and IT environments.

Common Transformer Applications

Our industrial transformers are used across a wide range of commercial and manufacturing applications, including:

  • CNC machines
  • HVAC controls
  • lighting
  • telecom gear

Why Choose Wistex for Transformers

At Wistex, you'll find top-tier industrial transformers, unmatched product knowledge, and personalized service. Our team helps you choose the right kVA, phase, and enclosure (including NEMA 3R and NEMA 4 options). We stock premium brands, offer same-day quotes, and ship fast so your project stays on schedule.

Transformer FAQs

Get answers to common questions about selecting and installing transformers.

To size a control transformer, calculate the total VA (volt-amperes) load of connected components and apply the 80% loading rule to ensure continuous operation. Always round up to the nearest available size.

A buck-boost transformer offers an affordable solution for small voltage corrections, which are ideal when you need to adjust incoming voltage by 5-20%. These units are compact, efficient, and cost less than larger isolation or control transformers.

Yes. OSHA and NEC require a means of disconnect for transformer maintenance and lock-out/tag-out compliance. Consider pairing your transformer with a proper disconnect switch to stay compliant and safe.