S801+T24N3S

Soft Starter (240 Amps)
Representative image shown

$5,746.28
$12,957.65
Product Condition: New

Eaton S801+ soft starter, 240 A, T-frame, Three-pole, 24 V power, 200-600 V, 47-63 Hz, 1-2 conductors, #4 AWG to 500 kcmil wire, 120 Vdc, 240 Vac, CIM, Used with: Three-phase motors, Modbus RTU, NEMA 0, LCD display, -30°C to -50°C

SKU:
S801+T24N3S
UPC:
786685558837
Weight:
48.00 LBS
Width:
14.50 in
Height:
12.50 in
Depth:
19.00 in
Series:
S801+
Amperage:
240 Amps
Frame Size:
T

S801+ Soft Starter Features

The Eaton S811+/S801+ soft starter family delivers solid performance beyond standard protection features found in most soft starters. Choosing a soft starter will increase your productivity and reduce your costs by:

  • Eliminating abrupt starts and stops, extending mechanical life of system • Better control of motor torque, increasing gearbox and bearing life, reducing belt wear and eliminating water hammer
  • Lowering inrush, reducing peak demand charges
  • Reducing brownouts and decreasing overall energy usage
  • Integrating overload protection
  • Reducing number of devices, panel size, installation time and assembly costs with internal run bypass contactors

S801+ Soft Starter Benefits

Smaller Size

The S811+/S801+ units are among the smallest starters in the industry. Reducing enclosure size for new production units, and enabling easier retrofits, minimizes the system costs

Severe Duty Capable

The S811+/S801+ soft starters have been time tested in various applications and environments. This family features conformally coated boards suitable for harsh environments. Kick-start function enables soft starting of high inertia loads.

Integrated Advanced Intelligence

High levels of protection are built into the S811+/S801+ soft starters.

  • Protective features: electronic overload, jam, stall, SCR over-temperature, phase loss, phase imbalance, automatic or manual reset, phase reversal, shorted SCR detection, open SCR detection, undercurrent, under-voltage, over-voltage, diagnostics

Packaged Options

Packaged S811+/S801+ units give you more starting torque and more motor current in dramatically reduced enclosures. Enclosed soft starter units are up to 78 percent smaller, and MCC units are up to 63 percent smaller, than competitive offerings.

S801+ Soft Starter Specifications

Product Length / Depth
19 in
Product Height 12.5 in
Product Width
14.5 in
Product Weight
45 lb
Certifications IEC 947
CSA Certified
EN 60947-4-2
CSA Certified for Elevator Duty
AC Current - Max 240 Vac
DC Current - Max 120 Vdc
Wire Size #4 AWG-500 kcmil
Operating Temperature - Min -30 °C
Power Supply 24 V
Size NEMA 0
Amperage Rating 240A
Number of Poles Three-pole
Display Material LCD
Frame Size T
Type Soft Starter
Operating Voltage 200-600 V
Used with Three-phase motors
Operating Temperature - Max 50 °C
Nema Rating NEMA 0
Frequency Rating 47-63 Hz
Module Interface CIM
Communication Modbus RTU
Initial Torque 0–85%
Ramp Time Range 0.5–180 seconds
Soft Stop Time Range 0–60 seconds
Kick-Start Time Range 0–2 seconds
Vibration Resistance - non-operating 3 g
Vibration Resistance - operating 3 g
Shock Resistance 15 g
Operating Voltage 200–600 V (T-, V-Frame—up to 690 V)
Overload Setting (frame) 30–100% FLA
Trip Class 5, 10, 20, 30
Voltage Range (24V ±10%) 21.6–26.4 V
Steady-State Current 1 A
In-Rush Current 10 A
Voltage AC - maximum 230 V
Voltage DC - maximum 24 V
Amperes - maximum 3 A
Temperature - operating –30 °C to +50 °C
Temperature - storage –50 °C to +70 °C
Altitude <2000 m
Humidity <95% noncondensing
Operating Position Any
Pollution Degree (IEC947-1) 3
Impulse Withstand Voltage (IEC947-4-1) 6000 V
Show MoreLess

Warranty Information

Manufacturer's Warranty: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.

Related Products