ABB
1SNA645514R2100
Rbr111-24Vuc
$25.30$33.33 -
ABB
1SNA645518R0500
Rbr111R-24Vuc
$44.00$136.75 -
ABB
1SNA645519R0600
Rbr101R-24Vuc
$45.01$139.87 -
ABB
1SNA645520R0300
Rbr121-60-230Vuc
$76.49$99.48 -
ABB
1SNA645521R2000
Obric0100-24Vdc
$35.76$66.05 -
ABB
1SNA645522R2100
Obric0100-115-230
$43.75$135.92 -
ABB
1SNA645524R2300
Obroc5000-24Vdc
$66.65$123.09 -
ABB
1SNA645525R2400
Obroc2000-24Vuc
$52.79$83.25 -
ABB
1SNA645526R2500
Obroc2000-230Vuc
$58.05$180.37 -
ABB
1SNA645527R2600
Obroa1000-24Vdc
$52.79$164.03 -
ABB
1SNA645528R0700
Obroa1000-230Vuc
$58.89$182.98 -
ABB
1SNA645529R0000
Obroa2000-24Vdc
$67.51$106.95 -
ABB
1SNA645534R2500
Rbr121P-5Vdc
$33.80$105.02 -
ABB
1SNA645535R2600
Rbr121P-12Vdc
$33.31$61.53 -
ABB
1SNA645540R1700
Rbr122G-48-60Vuc
$42.78$67.12 -
ABB
1SNA645541R0400
Rbr122G-115Vuc
$53.31$98.45 -
ABB
1SNA645547R0200
Obric0100-5-12Vdc
$40.49$74.77 -
ABB
1SNA645549R1400
Obric0100-48-60Vuc
$40.10$105.97 -
ABB
1SNA645550R1100
Obroc2000-5-12Vdc
$55.54$102.56 -
ABB
1SNA645551R0600
Obroc2000-24Vdc
$51.60$81.35 -
ABB
1SNA645553R0000
Obroc2000-48-60Vuc
$47.46$61.73 -
ABB
1SNA645554R0100
Obroc2000-115Vuc
$56.93$176.88 -
ABB
1SNA645559R1600
Obroc5000-230Vuc
$79.91$248.33 -
ABB
1SNA645562R0100
Obroa1000-115Vuc
$56.18$174.57 -
ABB
1SNA645571R0000
Rbr121-24Vdc
$21.76$40.18 -
ABB
1SNA645572R0000
Rbr121G-24Vdc
$103.84$322.63 -
ABB
1SNA645573R0000
Rbr121-12Vdc
$119.28$370.58 -
ABB
1SNA645575R0000
Rbr121G-12Vdc
$32.24$100.20
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.