-
Littelfuse
TDS230AL
Digi-Set (Single Shot)
$361.27 -
Littelfuse
TDS24AL
Digi-Set (Single Shot)
$361.27 -
Littelfuse
TDSH120AL
Digi-Set (Single Shot)
$361.27 -
Littelfuse
TDSL120AL
Digi-Set (Single Shot)
$361.27 -
ATC
TDT-120-AKA-010
True Off Delay Time Delay Relay 110/120 V AC/DC
$239.04$282.30 -
ATC
TDT-120-AKA-030
True Off Delay Time Delay Relay 110/120 V AC/DC
$239.04$282.30 -
ATC
TDT-120-AKA-060
True Off Delay Time Delay Relay 110/120 V AC/DC
$239.04$282.30 -
ATC
TDT-120-ALA-060
True Off Delay Time Delay Relay 110/120 V AC/DC
$283.66$335.01 -
ATC
TDT-120-ALA-200
True Off Delay Time Delay Relay 110/120 V AC/DC
$241.16$284.82 -
ATC
TDT-24-AKA-010
TRUE DELAY-ON-RELEASE TIME
$265.60$313.68 -
ATC
TDT-24-AKA-060
TRUE DELAY-ON-RELEASE TIME
$303.54$358.48 -
ATC
TDT-240-AKA-010
True Off Delay Time Delay Relay 208/240 V AC/DC
$245.72$290.20 -
ATC
TDT-240-AKA-030
True Off Delay Time Delay Relay 208/240 V AC/DC
$252.85$298.62 -
ATC
TDT-240-AKA-060
True Off Delay Time Delay Relay 208/240 V AC/DC
$266.66$314.93 -
ATC
TDT-240-AKA-100
True Off Delay Time Delay Relay 208/240 V AC/DC
$250.72$296.11 -
ATC
TDT-240-AKA-300
True Off Delay Time Delay Relay 208/240 V AC/DC
$322.81$381.25 -
ATC
TDT-24A-KA0-030
TRUE DELAY-ON-RELEASE TIME
$265.60$313.68 -
ATC
TDU-120-AKA
Multi-Mode Time Delay Relay 110/120 V AC/DC
$191.23$225.84 -
Littelfuse
TDU3000A
Solid State Timer
$128.23 -
Littelfuse
TDU3001A
Solid State Timer
$128.23 -
Littelfuse
TDU3003A
Solid State Timer
$128.23 -
Littelfuse
TDUB3000A
Digi-Set Timer-Delay On Break
$225.76 -
Littelfuse
TDUB3002A
Digi-Set Timer-Delay On Break
$225.76 -
Littelfuse
TDUBH3001A
Digi-Set Timer-Delay On Break
$225.76 -
Littelfuse
TDUBH3002A
Digi-Set Timer-Delay On Break
$225.76 -
Littelfuse
TDUBL3002A
Digi-Set Timer-Delay On Break
$225.76 -
Littelfuse
TDUH3000A
Solid State Timer
$128.23 -
Littelfuse
TDUH3001A
Solid State Timer
$128.23
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.