Littelfuse
SE-325DN
Ngr Monitor 120 Vac/Vdc Non-Latching
$6,401.99 -
Littelfuse
SE-325DNT
Ngr Mon 120Vac/Vdc Non-Latch Gf 0.1-5S
$7,263.57 -
Littelfuse
SE-325DS
Ngr Monitor 120 Vac/Vdc Ext Rf Trip
$6,401.99 -
Littelfuse
SE-325DSN
Ngr Mon 120Vac/Vdc Non-Latch Ext Rf Time
$7,263.57 -
Littelfuse
SE-325DSNT
Ngr Mon 120Vac/Vdc Nl Ext Rf Gf 0.1-5S
$8,125.23 -
Littelfuse
SE-325DST
Ngr Mon 120Vac/Vdc Ext Rf Gf 0.1-5S
$7,263.57 -
Littelfuse
SE-325DT
Ngr Mon 120Vac/Vdc Gf Time 0.1 To 5 S
$6,401.99 -
Littelfuse
SE-325E
Ngr Monitor 240 Vac
$3,942.73 -
Littelfuse
SE-325EN
Ngr Monitor 240 Vac Non-Latching
$4,810.11 -
Littelfuse
SE-325ENT
Ngr Mon 240 Vac Non-Latch Gf 0.1-5S
$5,671.70 -
Littelfuse
SE-325ES
Ngr Mon 240 Vac Extended Rf Trip Time
$4,810.11 -
Littelfuse
SE-325ESN
Ngr Mon 240 Vac Ext Rf Non-Latching
$5,671.70 -
Littelfuse
SE-325ESNT
Ngr Mon 240 Vac Ext Rf Nl Gf 0.1-5S
$6,533.27 -
Littelfuse
SE-325EST
Ngr Mon 240 Vac Ext Rf Gf Time 0.1-5S
$5,671.70 -
Littelfuse
SE-325ET
Ngr Mon 240 Vac Gf Time 0.1-5S
$4,810.11 -
Littelfuse
SE-325N
Ngr Monitor 120 Vac Non-Latching
$4,810.11 -
Littelfuse
SE-325NT
Ngr Mon 120 Vac Non-Latch Gf 0.1-5 S
$5,671.70 -
Littelfuse
SE-325P
Ngr Mon 120 Vac 4K8 Ngr Short Detect
$4,810.11 -
Littelfuse
SE-325S
Ngr Monitor Ext Res Trip Time
$4,810.11 -
Littelfuse
SE-325SN
Ngr Mon Extended Rf Trip Non-Latch
$5,671.70 -
Littelfuse
SE-325SNT
Ngr Mon 120 Vac Ext Rf Gf Time 0.1-5S
$6,533.27 -
Littelfuse
SE-325ST
Ngr Mon Extended Rf Time Gf 0.1-5 S
$5,671.70 -
Littelfuse
SE-325T
Ngr Monitor 120 Vac Gf Time 0.1-5 S
$4,810.11 -
Littelfuse
SE-330-00-00
Neutral-Grounding-Resistor Monitor
$10,545.75 -
Littelfuse
SE-330-00-01
Ngr Monitor Nc
$10,545.75 -
Littelfuse
SE-330-01-00
Neutral-Grounding-Resistor Monitor Devic
$15,150.41 -
Littelfuse
SE-330-01-01
Ngr Monitor Nc Devicenet
$15,150.41 -
Littelfuse
SE-330-03-00
Neutral-Grounding-Resistor Monitor Ether
$14,709.15
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.