Electrical Relays

  • PLM6405 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM6405

    3 Phase Line Monitor

    $391.08
  • PLM6502 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM6502

    3 Phase Line Monitor

    $391.08
  • PLM6805 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM6805

    3 Phase Line Monitor

    $391.08
  • PLM8405 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM8405

    3 Phase Line Monitor

    $391.08
  • PLM9405 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM9405

    3 Phase Line Monitor

    $391.08
  • PLM9502 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM9502

    3 Phase Line Monitor

    $391.08
  • PLM9805 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLM9805

    3 Phase Line Monitor

    $391.08
  • PLMU11 Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLMU11

    3 Phase Line Monitor

    $463.67
  • PLR120A Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLR120A

    3 Phase Line Monitor

    $337.69
  • PLR240A Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLR240A

    3 Phase Line Monitor

    $337.69
  • PLR380A Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLR380A

    3 Phase Line Monitor

    $337.92
  • PLR480A Littelfuse 3 Phase Line Monitor
    Littelfuse

    PLR480A

    3 Phase Line Monitor

    $337.92
  • PLRO-100 RK Electronics Phase Loss/Reversal,100/120VAC 3√ò DPDT
    RK Electronics

    PLRO-100

    Phase Loss/Reversal,100/120VAC 3√ò DPDT

    $197.65
    $280.00
  • PLRO-200 RK Electronics Phase Loss/Reversal,208/240VAC 3√ò DPDT
    RK Electronics

    PLRO-200

    Phase Loss/Reversal,208/240VAC 3√ò DPDT

    $204.71
    $290.00
  • PLRO-300 RK Electronics Phase Loss/Reversal,380/415VAC 3√ò DPDT
    RK Electronics

    PLRO-300

    Phase Loss/Reversal,380/415VAC 3√ò DPDT

    $218.82
    $310.00
  • PLRO-400 RK Electronics Phase Loss/Reversal,440/480VAC 3√ò DPDT
    RK Electronics

    PLRO-400

    Phase Loss/Reversal,440/480VAC 3√ò DPDT

    $218.82
    $310.00
  • PLRO-600 RK Electronics Phase Loss/Reversal,575/600VAC 3√ò DPDT
    RK Electronics

    PLRO-600

    Phase Loss/Reversal,575/600VAC 3√ò DPDT

    $225.88
    $320.00
  • PLS120A Littelfuse Reverse Phase Relay
    Littelfuse

    PLS120A

    Reverse Phase Relay

    $268.33
  • PLS240A Littelfuse Reverse Phase Relay
    Littelfuse

    PLS240A

    Reverse Phase Relay

    $268.33
  • PMA Littelfuse Enc Panel Adaptor Mpu-16A Rough Cutout
    Littelfuse

    PMA

    Enc Panel Adaptor Mpu-16A Rough Cutout

    $314.13
  • PMA-1 Littelfuse Enc Panel Adaptor Mpu-16A/Multilin 269
    Littelfuse

    PMA-1

    Enc Panel Adaptor Mpu-16A/Multilin 269

    $955.56
  • PMA-13 Littelfuse Mps Panel-Mount Adapter - Ge 269+
    Littelfuse

    PMA-13

    Mps Panel-Mount Adapter - Ge 269+

    $955.56
  • PMA-14 Littelfuse Enc Panel Adaptor Mps/A-B1406
    Littelfuse

    PMA-14

    Enc Panel Adaptor Mps/A-B1406

    $955.56
  • PMA-15 Littelfuse Se-70X Ipc Mgfr Adapter(Requires Pma-55)
    Littelfuse

    PMA-15

    Se-70X Ipc Mgfr Adapter(Requires Pma-55)

    $314.13
  • PMA-2 Littelfuse Enc Panel Adaptor Mpu-16A/A-B 1406
    Littelfuse

    PMA-2

    Enc Panel Adaptor Mpu-16A/A-B 1406

    $955.56
  • PMA-24 Littelfuse Ge Multilin 469 To Mps Adapter Hdwr Only
    Littelfuse

    PMA-24

    Ge Multilin 469 To Mps Adapter Hdwr Only

    $1,449.25
  • PMA-55 Littelfuse Enc Panel Adaptor Se-701 S To P 55Mm Cas
    Littelfuse

    PMA-55

    Enc Panel Adaptor Se-701 S To P 55Mm Cas

    $314.13
  • PMA-6 Littelfuse Enc Panel Adaptor Se-701 To Fpl-Gfrm
    Littelfuse

    PMA-6

    Enc Panel Adaptor Se-701 To Fpl-Gfrm

    $314.13

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.