Electrical Relays

  • MGS-120A-1S-2 RK Electronics SS Off Delay 120VAC Fixed 2 Sec, Screw
    RK Electronics

    MGS-120A-1S-2

    SS Off Delay 120VAC Fixed 2 Sec, Screw

    $127.06
    $180.00
  • MGS-120A-1S-3M RK Electronics SS Off Delay 120VAC Fixed 3 Min, Screw
    RK Electronics

    MGS-120A-1S-3M

    SS Off Delay 120VAC Fixed 3 Min, Screw

    $127.06
    $180.00
  • MGS-120A-1T-2 RK Electronics SS Off Delay 120VAC Fixed 2 Sec, Tab
    RK Electronics

    MGS-120A-1T-2

    SS Off Delay 120VAC Fixed 2 Sec, Tab

    $112.94
    $160.00
  • MGS-120A-2S RK Electronics SS Off Delay 120VAC Adj 45 Sec Screw
    RK Electronics

    MGS-120A-2S

    SS Off Delay 120VAC Adj 45 Sec Screw

    $127.06
    $180.00
  • MGS-120A-2T RK Electronics SS Off Delay 120VAC Adj 45 Sec Tab
    RK Electronics

    MGS-120A-2T

    SS Off Delay 120VAC Adj 45 Sec Tab

    $112.94
    $160.00
  • MGS-120A-3S RK Electronics SS Off Delay 120VAC, 5 Min Remote Screw
    RK Electronics

    MGS-120A-3S

    SS Off Delay 120VAC, 5 Min Remote Screw

    $127.06
    $180.00
  • MGS-120A-3T RK Electronics SS Off Delay 120VAC, 5 Min Remote Tab
    RK Electronics

    MGS-120A-3T

    SS Off Delay 120VAC, 5 Min Remote Tab

    $112.94
    $160.00
  • MGS-120A-4S RK Electronics SS Off Delay 120VAC, Remote Adj, Screw
    RK Electronics

    MGS-120A-4S

    SS Off Delay 120VAC, Remote Adj, Screw

    $127.06
    $180.00
  • MGS-120A-4T RK Electronics SS On Delay 24VDC, Remote Adj, Tab
    RK Electronics

    MGS-120A-4T

    SS On Delay 24VDC, Remote Adj, Tab

    $112.94
    $160.00
  • MGS-220A-1S-3M RK Electronics SS Off Delay 220VAC Fixed 3 Min, Screw
    RK Electronics

    MGS-220A-1S-3M

    SS Off Delay 220VAC Fixed 3 Min, Screw

    $127.06
    $180.00
  • MGS-24A-1S-15 RK Electronics SS Off Delay 24VAC Fixed 15 Sec, Screw
    RK Electronics

    MGS-24A-1S-15

    SS Off Delay 24VAC Fixed 15 Sec, Screw

    $127.06
    $180.00
  • MGS-24A-2S RK Electronics SS Off Delay 24VAC Adj 45 Sec, Screw
    RK Electronics

    MGS-24A-2S

    SS Off Delay 24VAC Adj 45 Sec, Screw

    $127.06
    $180.00
  • MGS-24A-2T RK Electronics SS Off Delay 24VAC Adj 45 Sec, Tab
    RK Electronics

    MGS-24A-2T

    SS Off Delay 24VAC Adj 45 Sec, Tab

    $112.94
    $160.00
  • MGS-24A-3S RK Electronics SS On Delay 24VAC, 5 Min Remote, Screw
    RK Electronics

    MGS-24A-3S

    SS On Delay 24VAC, 5 Min Remote, Screw

    $127.06
    $180.00
  • MGS-24A-3T RK Electronics SS On Delay 24VAC, 5 Min Remote, Tab
    RK Electronics

    MGS-24A-3T

    SS On Delay 24VAC, 5 Min Remote, Tab

    $112.94
    $160.00
  • MGS-24D-2S RK Electronics SS Off Delay 24VDC Adj 45 Sec, Screw
    RK Electronics

    MGS-24D-2S

    SS Off Delay 24VDC Adj 45 Sec, Screw

    $127.06
    $180.00
  • MGS-24D-2T RK Electronics SS Off Delay 24VDC Adj 45 Sec, Tab
    RK Electronics

    MGS-24D-2T

    SS Off Delay 24VDC Adj 45 Sec, Tab

    $112.94
    $160.00
  • MGS-24D-3S RK Electronics SS On Delay 24VDC, 5 Min Remote, Screw
    RK Electronics

    MGS-24D-3S

    SS On Delay 24VDC, 5 Min Remote, Screw

    $127.06
    $180.00
  • MGS-24D-3T RK Electronics SS On Delay 24VDC, 5 Min Remote, Tab
    RK Electronics

    MGS-24D-3T

    SS On Delay 24VDC, 5 Min Remote, Tab

    $112.94
    $160.00
  • Tele Controls

    MP GAMMA

    DIN Rail Adapter plate for ENYA, VEO and GAMMA Series

    $1.70
  • Tele Controls

    MP

    DIN Rail Adapter plate for ENYA and VEO Series

    $1.70
  • MP8000 Littelfuse Motor Overload Protection 8000
    Littelfuse

    MP8000

    Motor Overload Protection 8000

    $1,844.99
  • MP8010 Littelfuse Motor Overload Protection 8000
    Littelfuse

    MP8010

    Motor Overload Protection 8000

    $2,024.10
  • MPA2-240-CT ATC Motor Protection Analyser 208/220/240 vac ext. C/T
    ATC

    MPA2-240-CT

    Motor Protection Analyser 208/220/240 vac ext. C/T

    $554.19
    $639.45
  • MPA2-480-32 ATC Motor Protection Analyser 440/480 vac 10-32 amp
    ATC

    MPA2-480-32

    Motor Protection Analyser 440/480 vac 10-32 amp

    $554.19
    $639.45
  • MPA2-480-80 ATC Motor Protection Analyser 440/480 vac 25-80 amp
    ATC

    MPA2-480-80

    Motor Protection Analyser 440/480 vac 25-80 amp

    $554.19
    $639.45
  • MPA2-480-CT ATC Motor Protection Analyser 440/480 vac ext. C/T
    ATC

    MPA2-480-CT

    Motor Protection Analyser 440/480 vac ext. C/T

    $554.19
    $639.45
  • MPA2-COM ATC RS485 Communication Cable
    ATC

    MPA2-COM

    RS485 Communication Cable

    $170.39
    $176.40

Main Characteristics of WEG Overload Relays

WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.

On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.

WEG Solid-State Vs Thermal (Bimetallic) Overload Relays

Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.

In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.

However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.

Applications of WEG Overload Relays

WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.

Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.

Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.