-
RK Electronics
ATB-24A-4-1M
Anti-Tiedown Timer, 24VAC, Adj 1M Pulsed
$164.47$233.00 -
RK Electronics
ATB-24A-4-1S
Anti-Tiedown Timer, 24VAC, Adj 1S Pulsed
$169.41$240.00 -
RK Electronics
ATB-24A-4-5S
Anti-Tiedown Timer, 24VAC, Adj 5S Pulsed
$169.41$240.00 -
RK Electronics
ATB-24D-1
Anti-Tiedown Timer, 24VDC, No Delay
$155.29$220.00 -
RK Electronics
ATB-24D-2
Anti-Tiedown Timer, Maint w/Pinch, 24VDC
$176.47$250.00 -
RK Electronics
ATB-24D-3-1.5S
Anti-Tiedown Timer, 24VDC, 1.5Sec Pulsed
$197.65$280.00 -
RK Electronics
ATB-24D-3-1S
Anti-Tiedown Timer, 24VDC, 1Sec Pulsed
$197.65$280.00 -
RK Electronics
ATB-24D-3-2.5S
Anti-Tiedown Timer, 24VDC, 2.5Sec Pulsed
$197.65$280.00 -
RK Electronics
ATB-24D-3-5S
Anti-Tiedown Timer, 24VDC, 5 Sec Pulsed
$197.65$280.00 -
RK Electronics
ATB-24D-4-10S
Anti-Tiedown Timer, 24VDC, Adj10S Pulsed
$176.47$250.00 -
RK Electronics
ATB-24D-4-1M
Anti-Tiedown Timer, 24VDC, Adj 1M Pulsed
$176.47$250.00 -
RK Electronics
ATB-24D-4-1S
Anti-Tiedown Timer, 24VDC, Adj 1S Pulsed
$176.47$250.00 -
RK Electronics
ATB-24D-4-5S
Anti-Tiedown Timer, 24VDC, Adj 5S Pulsed
$176.47$250.00 -
Tele Controls
BRIDGE CS/CP 02 BLACK
Bridge for Series CS/CP sockets, plug-in bridge, pitch: 5.2 mm, number of positions: 2, length: 23 mm, color: black
$1.69 -
Tele Controls
BRIDGE CS/CP 02 BLUE
Bridge for Series CS/CP sockets, plug-in bridge, pitch: 5.2 mm, number of positions: 2, length: 23 mm, color: blue
$1.69 -
Tele Controls
BRIDGE SR 20P BK
Bridge for Series SR sockets, plug-in bridge, pitch: 5 mm, number of positions: 20, length: 124 mm, color: black
$4.41 -
Tele Controls
BS PSS
Tag for Relay Base PSS8/3
$0.41 -
Littelfuse
BZ1
Panel Mount Kit.
$92.04 -
Littelfuse
CA-945
Serial Adapter D9M To Rf45 W/ 5'
$167.33 -
RK Electronics
CAB-115A-4
Alternator, 115VAC, 11-Pin Base, DEI
$141.18$200.00 -
RK Electronics
CAB-230A-4
Alternator, 230VAC, 11-Pin Base, DEI
$141.18$200.00 -
RK Electronics
CAB-24A-4
Alternator, 24VAC, 11-Pin Base, DEI
$141.18$200.00 -
ATC
CBA-120-ALE-1
AC Over and Under Current Band Monitor/Relays
$487.44$575.68 -
ATC
CBA-120-ALE-10
AC Over and Under Current Band Monitor/Relays
$478.07$564.62 -
ATC
CBA-120-ALE-20
AC Over and Under Current Band Monitor/Relays
$499.32$589.71 -
ATC
CBA-120-ALE-30
AC Over and Under Current Band Monitor/Relays
$435.58$514.43 -
ATC
CBA-120-ALE-40
AC Over and Under Current Band Monitor/Relays
$531.20$627.35 -
ATC
CBA-120-ALE-5
AC Over and Under Current Band Monitor/Relays
$478.07$564.62
Electrical Relays
Main Characteristics of WEG Overload Relays
WEG overload relays are available in both three-pole and two-pole versions. The relays count on two independent and extremely reliable built-in auxiliary contacts (12 V, 10 mA). When properly wired in series with the contactor coil, the auxiliary contacts assure the motor is switched off whenever a failure occurs, but it can also be used for system monitoring purposes.
On the front side, the relay features a RESET pushbutton and a TEST switch, which both function to allow checking proper wiring and the auxiliary contact’s status. The front side also contains a status window (TRIP) that shows the current operation status of the relay.
WEG Solid-State Vs Thermal (Bimetallic) Overload Relays
Traditional thermal overload relays are designed to imitate the heat actually produced in the motor. They effectively simulate the motor heating by passing the motor current through bimetal strips, either directly or indirectly. As the motor temperature rises, the temperature of the thermal unit of the relay similarly rises. The generated heat then bends the bimetal strips and, based on the current setting of the relay, activates the trip mechanism.
In most normal applications, continuous duty or low number of motor start-ups are common. In such situations, the relationship between motor and relay heating curves is very strong. No matter how high the current taken by the motor is, a thermal overload relay will provide protection without tripping unnecessarily.
However, in intermittent duty applications or frequent motor start-ups, the increase in heating behaves slightly differently in the bimetal strip than in the motor windings, so it’s common to experience undesired early tripping. In such situations, you can rarely utilize the thermal capacity of the motor, and thermal overload relays may not be the most suitable solution.
Applications of WEG Overload Relays
WEG overload relays are designed to protect both three-phase and single-phase AC motors, as well as DC motors. In applications where WEG overload relays are used in the protection of single-phase AC or DC loads, be sure to follow the wiring diagrams presented by the manufacturer.
Overall, WEG solid-state overload relays are suitable for protecting motors in a wide range of industrial applications, including those where prolonged starting time is required. WEG relays can effectively protect motors on low, medium, or heavy-duty applications by simply selecting the proper trip class (such as 10, 20, or 30 as per the IEC 60947-4-1 requirements) in the DIP-switches.
Additionally, the micro-processed electronic circuits of WEG overload relays are temperature compensated, which means that the tripping point remains steady in the entire temperature range of between -20 °C and +60 °C, and it performs consistently without unnecessary tripping.