Representative image shown

HF9-ROLE

Electronic Compact Reversing Starter with Emergency Stop (24 VDC)

$337.46
Factory New

ABB, Electronic Compact Reversing Starter, a 3-in-1 electronic compact reversing motor starter featuring integrated safety stop functions, contactors, and overload relay protection for motors up to 9.0 A, Saves panel space and cuts wiring time

Representative image shown
Product Details
SKU:
HF9-ROLE
UPC:
4013614515538
Weight:
0.63 LBS
Width:
0.88 in
Height:
3.89 in
Depth:
4.50 in
Current Setting Range:
1.5 A to 9.0 A
Control Supply Voltage:
24 V DC
Maximum Operating Voltage:
550 V AC
Number of Poles:
3 Poles

Description

Description

The HF-ROLE-range is our safety range with emergency stop function. It's used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF9-ROLE-24VDC is 1.5 A to 9 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1 are certified. Also ATEX is certified.

Specifications

Specifications

Technical

 
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-2
IEC/EN 61508
IS0 13849
UL 60947-1
UL 60947-4-2
Function: Reversed-on-line starter with electronic overload protection and emergency stop function
Utilization: Motor Protection
Rated Operational Voltage: Main Circuit 500 V AC
Operational Voltage:
Maximum 550 V AC
Minimum 42 V AC
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Control Supply Voltage (Us): 24 V DC
Rated Input Voltage (UIN):
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 500 V
Rated Operational Current AC-51 (Ie): 9 A
Rated Operational Current AC-53a (Ie): 6.5 A
Rated Control Supply Current (Is): 0.04 A
Rated Uninterrupted Current (Iu): 9 A
Input Current: 0.003 A
Switching Frequency:
≤ 2 Hz
120 starts/min
7200 starts/h
Rated Operational Power AC-53a (Pe): 3 kW
Overvoltage Category: III
Overload Protection: Electronic overload protection
Setting Range: 1.5 ... 9.0 A
Trip Class: class 10A
Number of Poles: 3P
Power Loss:
Maximum 14.6 W
Minimum 1.1 W
Number of Protected Poles: 3
Mechanical Durability: Nr. Operations 10000 cycle
Electrical Durability: 30000000 cycle
Delay Time (τ):
Off, Maximum, Switched Off via Control Input Voltage 80 ms
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 s
Off, Minimum, Switched Off with Pushbutton 0.5 s
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position: 1
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Recommended Screw Driver:
Control Circuit M3
Main Circuit M3
Terminal Type: Screw Terminals
Tightening Torque:
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Wire Stripping Length:
Control Circuit 8 mm
Main Circuit 8 mm
Response Time:
Phase Asymmetry 33% 120 s
Phase Asymmetry 67% 1.8 s
Phase Failure 1.8 s
Pollution Degree: 2
Phase Loss Sensitive: Yes
Degree of Protection:
Housing IP20
Main Circuit Terminals IP20
Short-Circuit Current Rating (SCCR): (500 V AC, 30 A Class J or CC) 100 kA

Technical UL/CSA

 
Maximum Operating Voltage UL/CSA: Main Circuit 500 V AC
Horsepower Rating UL/CSA:
Nominal Switching Performance Full Load (power factor = 0.4) 3 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 6.1 Hp
Full Load Amps Motor Use: 6.5 A
Connecting Capacity Main Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Connecting Capacity Control Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Tightening Torque UL/CSA:
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb

Safety Information

 
Safety Integrity Level (SIL): 3
Safety Category: 3
Performance Level (PL): Up to e
Mean Time to Dangerous Failure (MTTFd):
Motor Protection 447 year
Safe Shutdown 517 year
Mean Time to Failure (MTTF): 39.3 year
Diagnostic Coverage: 98.79 %
Diagnostic Coverage Safe (DCS): 40.71 %

Environmental

 
Ambient Air Temperature:
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Maximum Operating Altitude Permissible: Without Derating 2000 m