Representative image shown

SCE-86ML3D20

3DR Left Multi-Door Enclosure

Representative image shown
Product Details
SKU:
SCE-86ML3D20
Weight:
1,450.00 LBS
Dimensions:
86in x 112.5in x 20in

Construction

Construction

SCE-86ML3D20 Saginaw Control & Engineering 86 x 112.5 x 20 3DR Left Multi-Door Enclosure

  • 0.125 In. carbon steel.
  • Seams continuously welded and ground smooth.
  • Heavy duty lifting eyes.
  • Reinforced top.
  • Steel stiffeners welded to back inside of enclosure.
  • Overlapping two-door openings have no center post.
  • Black zinc die cast padlocking handle.
  • 3-point latching mechanism.
  • Concealed hinges.
  • Mechanical interlock.
  • Far right hand door is main door.
  • Panel supports.
  • Interior print pocket.
  • Removable panels are mounted on collar studs.
  • Provisions for light kit.
  • Pour in place oil & water resistant gasket
  • Ground stud on door and body.
  • Removable print pocket.
  • Flange trough collar around all sides of door opening.
  • Hole plugs provided to seal holes in bottom of enclosure.
  • Collar studs 3/8-16 provided for mounting panels.

Application

Application

SCE-86ML3D20 Saginaw Control & Engineering 86 x 112.5 x 20 3DR Left Multi-Door Enclosure

Designed to house electrical equipment and provide protection from dirt, dust, oil and water. For outdoor application a drip shield and drain vent is recommended.

Finish

Finish

SCE-86ML3D20 Saginaw Control & Engineering 86 x 112.5 x 20 3DR Left Multi-Door Enclosure

ANSI-61 gray powder coating inside and out. Sub-panels are powder coated white.

 

Industry Standards

Industry Standards

SCE-86ML3D20 Saginaw Control & Engineering 86 x 112.5 x 20 3DR Left Multi-Door Enclosure

  • NEMA Type 3R, 12 and Type 13
  • UL Listed Type 3R and 12
  • CSA Type 3R and 12
  • IEC 60529
  • IP 55

NEMA Rating for

Nema active
N1
Indoor
Protection from fingers, tools and small objects
Nema active
N12
Indoor
Protection from dust and light splashes of water
Nema active
N3R
Outdoor
Protection from rain, snow and sleet
Nema not active
N4
Outdoor
Protection from rain, snow, sleet, and hose directed water
Nema not active
N4X
Outdoor
Protected from rain, snow, sleet, and pressure rated hose directed water from all angles
N1 graphic N12 graphic N3R graphic N4 graphic N4X graphic
+
Environments Type 1 Type 12 Type 3R Type 4 Type 4X
Indoor use only
Indoor and outdoor use
Falling liquids and light splashes
Nonhazardous dust, lint, and fibers
Washdowns and splashing water
Oil and coolant seepage
Corrosive agents
Hazardous locations
(Class I, Division 1 and 2)