ZPSA-600-EH1-FR4

UL Type 1 External Heatsink Adapter
Representative image shown
Product Condition: New
SKU:
ZPSA-600-EH1-FR4
Weight:
2.00 LBS

This option will change an open-chassis type (IP20) drive to an enclosed wall-mounted type (UL Type 1) drive. This option will let you install the drive outside the enclosure panel as an enclosed wall mounted type drive. The option has a bracket that will prevent damage to the wiring and a top protective cover that will not let unwanted material get in the drive. You can use this option when the installation environment of the drive meets the specifications shown in Installation Environment on page 8.

This installation kit is compatible with these drives:
  • GA700
  • GA800
  • CH700
  • CR700
  • HV600
  • FP605

Installation Environment

Area of Use Indoors
Power Supply Overvoltage Category III
Ambient Temperature Setting
IP20/UL Open Type: -10 °C to +50 °C (14 °F to 122 °F)
IP20/UL Type 1: -10 °C to +40 °C (14 °F to 104 °F)
  • Drive reliability is better in environments where the temperature does not increase or decrease
    quickly.
  • When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the internal
    air temperature in the permitted range.
  • Do not let the drive freeze.
  • You can use IP20/UL Open Type drives at a maximum of 60 °C (140 °F) when you derate the output current.
  • You can use IP20/UL Type 1 drives at a maximum of 50 °C (122 °F) when you derate the output current.
Humidity 95% RH or less. Do not let condensation form on the drive.
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Surrounding Area
Pollution degree 2 or less
Install the drive in an area without:
  • Oil mist, corrosive or flammable gas, or dust
  • Metal powder, oil, water, or other unwanted materials
  • Radioactive or flammable materials.
  • Harmful gas or fluids
  • Salt
  • Direct sunlight Keep wood and other flammable materials away from the drive
Altitude
1000 m (3281 ft) Maximum
Note: Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
  • Installing the drive at 2000 m (6562 ft) or lower
  • Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply. Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
Vibration
  • 10 Hz to 20 Hz: 0.6 G (5.9 m/s2, 19.30 ft/s2)
  • 20 Hz to 55 Hz: Different for different models. Refer to the manual packaged with the drive.
 Installation Orientation Install the drive vertically for sufficient airflow to cool the drive.