Representative image shown

Ex9R100B70A

Thermal Overload Relay (55-70 Amps)

$67.49
Factory New

Thermal overload relay (TOR) - NOARK (Ex9R series) - 55A...70A current setting range - 3-poles (3P) - 1NO+1NC (1 Normally Open + 1 Normally Closed) aux. contacts - Screw-clamp connections - Direct mounting - frame size 100AF

Representative image shown
Product Details
SKU:
Ex9R100B70A
Weight:
5.00 LBS
Series:
Ex9R
Rated Current:
55 - 70 Amps
Rated Operating Voltage:
600 V
Rated Impulse Voltage:
6 kV

Specifications

Specifications
Primary brand NOARK
Main function Thermal Overload Relay (TOR)
Product series / family name Industrial controls > Overload relays
Sub-range name Ex9R series
Network frequency
50/60 Hz
Functions
Thermal overload relay (TOR)
Automatic / manual reset function
Temperature compensation
Tripping indicator
TEST and STOP pushbutton
Poles 3-poles (3P)
Rated current
55A...70A current setting range
Contacts ratings
1.64A rated operating current (at 220Vac; AC-15; aux. contact)
0.95A rated operating current (at 380Vac; AC-15; aux. contact)
0.13A rated operating current (at 220Vdc; DC-13; aux. contact)
5A (continuous; at 600Vac; aux. contacts)
1A (continuous; at 300Vdc; aux. contacts)
Rated operating voltage (Ue)
600 V
Rated impulse voltage (Uimp)
6 kV
Connection type
Screw-clamp connections
18mm stripping length (main power connections)
11mm stripping length (aux. contact connections)
Cross-section
#12AWG...#10AWG / 4mm2...6mm2 conductors (main power connection; rigid cable)
#8AWG...#1AWG / 10mm2...50mm2 conductors (main power connection; flexible cable)
#18AWG...#12AWG / 1mm2...2.5mm2 conductors (auxiliary contact terminal connection)
Short circuit breaking rating
10kA (3-phase at 600Vac)
Protection functions Adjustable thermal protection (Overload) Class 10A
Phase failure protection
Protection settings
Protection against thermal overload -- 55A...70A (adjustable)
Phase failure -- 0.3 x In sensitivity
Mounting mode
Direct mounting
Contacts type
1NO+1NC (1 Normally Open + 1 Normally Closed) aux. contacts
Dimensions frame size 100AF
H3.15" x W2.83" x D4.61"
H80mm x W72mm x D117mm
Technical compatibility with
40-100A Ex9C devices
Minimum current
55 A
Maximum current
70 A
Order code / Manufacturer SKU
Ex9R100B70A
1420029
Manufacturer product status
Commercialized
Equivalent to
1420029
Compliant with standard(s)
UL listed (file number E353865)
UL 60947-1
UL 60947-4-1
IEC/EN 60947-4-1
cUL
CE
CCC
CSA
Class 10
Tightening torque
(main power connection) 9 N.m
(auxiliary contact connection) 1.7 N.m
Degree of pollution III
Application type
2000m / 6562ft max. operating altitude

Benefits

Benefits
  • For use with Ex9C and Ex9CR
  • Rated current up to 500A at 600Vac‚ 50/60Hz
  • Overload protection trip Class 10 and Class 10A
  • Phase loss sensitivity
  • Adjustable current setting for overload protection
  • Automatic or manual reset selectable
  • Status indication
  • STOP and TEST function
  • Direct mount to contactors or 35mm DIN rail mounting base option
  • 5-year limited warranty