MS325-12.5HKF11

Manual Motor Starter ( 9.0 A to 12.5 A)

$208.36
Factory New

ABB, Manual Motor Starter, 54 mm width devices with a rated operational current of Ie = 12.5 A, pre-assembled front mounted auxiliary contact HKF1-11.

Representative image shown
Product Details
SKU:
MS325-12.5HKF11
UPC:
4013614302497
Weight:
0.79 LBS
Width:
2.13 in
Height:
3.44 in
Depth:
2.97 in
Number of Poles:
3 Pole
Rated Operational Current:
12.5 Amperage

Description

Description

The MS325-12.5-HKF11 manual motor starter is a 54 mm width devices with a rated operational current of Ie = 12.5 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 75 kA at 400 VAC and the trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

Specifications

Specifications

Technical

 
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 5 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 180 A
Setting Range: 9 ... 12.5 
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 5.5 kW
Rated Operational Voltage: Main Circuit 690 V AC
Main Circuit 440 V DC
Rated Operational Current (Ie): 12.5 A
Rated Operational Current AC-3 (Ie): 12.5 A
Rated Frequency (f): Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Power Loss: at Rated Operating Conditions per Pole 1.0 ... 1.8 W
Number of Poles: 3
Mounted Auxiliary Contacts: 1 NO, 1 NC
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 1
Conventional Free-air Thermal Current (Ith): Main Circuit 12.5 A
Degree of Protection: IP20
Pollution Degree: 3
Electrical Durability: 50000 cycle
Mechanical Durability: 100000 cycle
Wire Stripping Length: Auxiliary Circuit 8 mm
Main Circuit 10 mm
Recommended Screw Driver: M3.5
Pozidriv 2

Mounting Position:

Position 1 to 6
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards: IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 508
CSA 22.2 No. 14

Environmental

 
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 10 ... 150 Hz

Technical UL/CSA

 
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Horsepower Rating UL/CSA: (220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Ampere Rating UL/CSA: 12.5 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 14-8 AWG
Stranded 1/2x 14-8 AWG