Representative image shown

MS165-20

Manual Motor Starter (14-20A)

$339.95
Factory New

ABB, Manual Motor Starters, 14 to 20A, 55 mm, Protects motors safely from short circuits, overloads, and phase failures without needing a fuse, Features a rotary handle with clear ON, OFF, and TRIP positions, plus a built-in disconnect function

Representative image shown
Product Details
SKU:
MS165-20
UPC:
4013614486067
Weight:
2.09 LBS
Width:
2.17 in
Height:
5.62 in
Depth:
4.81 in
Current Range:
14 to 20A
Number of Poles:
3 Poles
Terminal Type:
Screw Terminals
Trip Class:
Class 10

Complete Your Build
verified Verified fit These products are compatible with the

Auxiliary Contacts
Signaling Contacts
Shunt Trips
Undervoltage Releases
Busbars
Hardware
Shafts

Build My Enclosure

Total price: $0

Description

Description

MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165 range.

Specifications

Specifications

Technical

 
Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 75 kA
(500 V AC) 40 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 300 A
Setting Range: 14 ... 20 A
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 7.5 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie): 20 A
Rated Operational Current AC-3 (Ie): 20 A
Rated Operational Current AC-3e (Ie): 20 A
Rated Operational Current DC-5 (Ie): 20 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
 Operating Frequency (fsw):  0 ... 415 Hz
 Rated Impulse Withstand Voltage (Uimp):  Main Circuit 8 kV
 Rated Insulation Voltage (Ui):  1000 V
 Power Loss:  at Rated Operating Conditions per Pole 1.82 ... 3.72 W
 Number of Poles:  3P
 Conventional Free-air Thermal Current (Ith):  Main Circuit 20 A
 Degree of Protection:  
Housing IP20
Main Circuit Terminals IP10
 Pollution Degree:  3
 Electrical Durability:  25000 cycle
 Mechanical Durability:  Nr. Operations 50000 cycle
 Terminal Type:  Screw Terminals
 Connecting Capacity Main Circuit:  
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
 Tightening Torque:  Main Circuit 4 N·m
 Wire Stripping Length:  Main Circuit 16 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: 1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Contact Position Indication: ON / OFF / TRIP
Standards:
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1

Technical UL/CSA

 
Short-Circuit Current Rating (SCCR):
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 15 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 16.7 A
(220 ... 240 V AC) Three Phase 15.2 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 17 A
Locked Rotor Amps:
(200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 102 A
(220 ... 240 V AC) Three Phase 92 A
(440 ... 480 V AC) Three Phase 81 A
(550 ... 600 V AC) Three Phase 93 A
General Use Rating UL/CSA: (600 V AC) 20 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSA: Main Circuit 35 in·lb

Environmental

 
Ambient Air Temperature:
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations:
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz