- SKU:
- MS132-0.16B
- UPC:
- 4013614521317
- Weight:
- 0.47 LBS
- Width:
- 1.77 in
- Height:
- 3.54 in
- Depth:
- 3.42 in
- Current Range:
- 0.10 to 0.16A
- Number of Poles:
- 3 Poles
- Terminal Type:
- Screw Terminals
- Trip Class:
- Class 10A
MS132-0.16B
Manual Motor Starter (0.10-0.16A)
ABB
ABB, Manual Motor Starter, 0.10-0.16A, 45 mm, Designed for reliable switching and fuse-less protection of low-voltage motors
Complete Your Build
verified
Verified fit
These products are compatible with the
Build My Enclosure
Total price: $0
Description
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS132-B/MS165-B range.
– designed in accordance to the applicable parts of IEC 60077 standard
– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)
– usable according to European fire and smoke safety standard EN 45545-2
Specifications
Technical |
|
| Rated Service Short-Circuit Breaking Capacity (Ics): |
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
|
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): |
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
|
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 2 A |
| Setting Range: | 0.10 ... 0.16 A |
| Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 0.03 kW |
| Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 0.03 kW |
| Rated Operational Voltage: |
Main Circuit 690 V AC
Main Circuit 250 V DC
|
| Rated Operational Current (Ie): | 0.16 A |
| Rated Operational Current AC-3 (Ie): | 0.16 A |
| Rated Operational Current AC-3e (Ie): | 0.16 A |
| Rated Operational Current DC-5 (Ie): | 0.16 A |
| Rated Frequency (f): |
Main Circuit 50 Hz
Main Circuit 60 Hz
|
| Operating Frequency (fsw): | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui): | 690 V |
| Power Loss: | at Rated Operating Conditions per Pole 0.7 ... 1.7 W |
| Number of Poles: | 3P |
| Conventional Free-air Thermal Current (Ith): | Main Circuit 0.16 A |
| Degree of Protection: |
Housing IP20
Main Circuit Terminals IP10
|
| Pollution Degree: | 3 |
| Electrical Durability: | 50000 cycle |
| Mechanical Durability: | Nr. Operations 100000 cycle |
| Terminal Type: | Screw Terminals |
| Connecting Capacity Main Circuit: |
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
|
| Tightening Torque: | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length: | Main Circuit 9 mm |
| Recommended Screw Driver: | Pozidriv 2 |
| Mounting Position: | 1 ... 6 |
| Mounting on DIN Rail: |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
|
| Minimum Mounting Distance: |
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
|
| Contact Position Indication: | ON / OFF / TRIP |
| Standards: |
IEC 60077-1 (applicable parts)
IEC 60077-2 (applicable parts)
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
|
| Remarks: | UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx |
Technical UL/CSA |
|
| Short-Circuit Current Rating (SCCR): |
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
|
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
| Full Load Amps Motor Use: |
(200 V AC) Three Phase 0.16 A
(208 V AC) Three Phase 0.16 A
(220 ... 240 V AC) Three Phase 0.16 A
(440 ... 480 V AC) Three Phase 0.16 A
(550 ... 600 V AC) Three Phase 0.16 A
|
| Locked Rotor Amps: |
(200 V AC) Three Phase 0.96 A
(208 V AC) Three Phase 0.96 A
(220 ... 240 V AC) Three Phase 0.96 A
(440 ... 480 V AC) Three Phase 0.96 A
(550 ... 600 V AC) Three Phase 0.96 A
|
| General Use Rating UL/CSA: | (600 V AC) 0.16 A |
| Connecting Capacity Main Circuit UL/CSA: |
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
|
| Tightening Torque UL/CSA: | Main Circuit 10 ... 12 in·lb |
Environmental |
|
| Ambient Air Temperature: |
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
|
| Ambient Air Temperature Compensation: | Yes |
| Maximum Operating Altitude Permissible: | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
| Resistance to Vibrations: | 5g 3 ... 150 Hz |
| Shock and Vibration Withstand acc. to IEC 61373: | Category 1, Class B |