- SKU:
- MS116-25
- UPC:
- 4013614405662
- Weight:
- 0.68 LBS
- Width:
- 1.77 in
- Height:
- 3.85 in
- Depth:
- 3.36 in
- Current Range:
- 20 to 25 A
- Number of Poles:
- 3 Poles
- Terminal Type:
- Screw Terminals
- Trip Class:
- Class 10A
MS116-25
Manual Motor Starter (20-25 A)
ABB
ABB, Manual Motor Starter, 45 mm, 20 to 25 A, Designed to reliably switch and protect motors from electrical faults
Complete Your Build
verified
Verified fit
These products are compatible with the
Build My Enclosure
Total price: $0
Description
The MS116-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
Specifications
Technical |
|
| Rated Service Short-Circuit Breaking Capacity (Ics): |
(230 V AC) 10 kA
(400 V AC) 10 kA
(440 V AC) 3 kA
(500 V AC) 3 kA
(690 V AC) 2 kA
|
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): |
(230 V AC) 16 kA
(400 V AC) 16 kA
(440 V AC) 15 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
|
| Rated Instantaneous Short-Circuit Current Setting (Ii): | 375 A |
| Setting Range: | 20 ... 25 A |
| Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 11 kW |
| Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 11 kW |
| Rated Operational Voltage: | Main Circuit 690 V AC |
| Rated Operational Current (Ie): | 25 A |
| Rated Operational Current AC-3 (Ie): | 25 A |
| Rated Operational Current AC-3e (Ie): | 25 A |
| Rated Frequency (f): |
Main Circuit 50 Hz
Main Circuit 60 Hz
|
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui): | 690 V |
| Power Loss: | at Rated Operating Conditions per Pole 1.8 ... 2.8 W |
| Number of Poles: | 3P |
| Conventional Free-air Thermal Current (Ith): | Main Circuit 25 A |
| Degree of Protection: |
Housing IP20
Main Circuit Terminals IP10
|
| Pollution Degree: | 3 |
| Electrical Durability: | 50000 cycle |
| Mechanical Durability: | Nr. Operations 100000 cycle |
| Terminal Type: | Screw Terminals |
| Connecting Capacity Main Circuit: |
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
|
| Tightening Torque: | Main Circuit 2 N·m |
| Wire Stripping Length: | Main Circuit 10 mm |
| Recommended Screw Driver: | Pozidriv 2 |
| Mounting Position: | 1 ... 6 |
| Mounting on DIN Rail: |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
|
| Minimum Mounting Distance: |
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
|
| Contact Position Indication: | ON / OFF |
| Standards: |
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
|
Technical UL/CSA |
|
| Short-Circuit Current Rating (SCCR): |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
|
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA: |
(200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
|
| Full Load Amps Motor Use: |
(200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 24.2 A
(220 ... 240 V AC) Three Phase 22 A
(440 ... 480 V AC) Three Phase 21 A
(550 ... 600 V AC) Three Phase 22 A
|
| Locked Rotor Amps: |
(200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 140 A
(220 ... 240 V AC) Three Phase 127 A
(440 ... 480 V AC) Three Phase 116 A
(550 ... 600 V AC) Three Phase 116 A
|
| General Use Rating UL/CSA: | (600 V AC) 25 A |
| Connecting Capacity Main Circuit UL/CSA: |
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
|
| Tightening Torque UL/CSA: | Main Circuit 18 in·lb |
Environmental |
|
| Ambient Air Temperature: |
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
|
| Ambient Air Temperature Compensation: | Yes |
| Maximum Operating Altitude Permissible: | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
| Resistance to Vibrations: |
2g 5 ... 150 Hz
5g 3 ... 150 Hz
|
Documents for
- Data Sheets MS116
- Installation Instructions MS116
- Time-Current Characteristic Curve MS116-25
- l2t Characteristic @400V MS116
- l2t Characteristic @500V MS116
- l2t Characteristic @690V MS116
- Cut-off Current Characteristics @400V MS116
- Cut-off Current Characteristics @500V MS116
- Cut-off Current Characteristics @690V MS116
- CAD Dimensional Drawing
- Dimension Diagram MS116(20A)