MO165-42

Manual Motor Starter Magnetic Only (42 A)

$398.17
Factory New

ABB, Manual Motor Starter, Compact 55 mm magnetic only, Provides compact, fuse-free short-circuit protection, manual ON/OFF switching, and a built-in disconnect function for industrial motor applications

Representative image shown
Product Details
SKU:
MO165-42
UPC:
4013614486166
Weight:
2.14 LBS
Width:
2.17 in
Height:
5.62 in
Depth:
4.81 in
Rated Operational Voltage:
690 V AC
Number of Poles:
3 Poles
Terminal Type:
Screw Terminals
Current Rating:
42 A

Complete Your Build
verified Verified fit These products are compatible with the

Auxiliary Contacts
Signaling Contacts
Shunt Trips
Undervoltage Releases
Busbars
Terminal Blocks
Shafts

Build My Enclosure

Total price: $0

Description

Description

The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.

Specifications

Specifications

Technical

 
Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 630 A
Setting Range: None
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 22 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie): 42 A
Rated Operational Current AC-3 (Ie): 42 A
Rated Operational Current AC-3e (Ie): 42 A
Rated Operational Current DC-5 (Ie): 42 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw): 0 ... 415 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Rated Insulation Voltage (Ui): 1000 V
Power Loss: 5.47 W
Number of Poles: 3P
Conventional Free-air Thermal Current (Ith): Main Circuit 42 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 25000 cycle
Mechanical Durability: Nr. Operations 50000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque: Main Circuit 4 N·m
Wire Stripping Length: Main Circuit 16 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: 1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Contact Position Indication: ON / OFF / TRIP
Standards:
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Remarks: For overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

 
Short-Circuit Current Rating (SCCR):
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 10 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 32.2 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 42 A
(440 ... 480 V AC) Three Phase 40 A
(550 ... 600 V AC) Three Phase 41 A
Locked Rotor Amps:
(200 V AC) Three Phase 186.3 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 232 A
(440 ... 480 V AC) Three Phase 218 A
(550 ... 600 V AC) Three Phase 232 A
General Use Rating UL/CSA: (600 V AC) 42 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSA: Main Circuit 35 in·lb

Environmental

 
Ambient Air Temperature:
Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: No
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations:
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz