Representative image shown

Ex9S80A40AM

Ex9S80 Manual Motor Starter (30-40 Amps)

$125.01
Factory New

Magnetic-only Manual Motor Starter (MMS) / Branch protector - low magnetic-trip threshold (below 15 x Ie) - NOARK (Ex9S80 series) - 30A...40A current setting range - Interrupting capacity 42kA (type E; 240Vac; 480Y/277Vac)

Representative image shown
Product Details
SKU:
Ex9S80A40AM
Weight:
5.00 LBS
Series:
Ex9S80
Rated Current:
30 - 40 Amps
Rated Impulse Voltage:
6 kV

Specifications

Specifications
Primary brand NOARK
Main function
Motor Protection Circuit Breaker (MPCB)
Product series / family name
Industrial controls > Manual Motor Starters (MMSs)
Sub-range name
Ex9S80 series
Network frequency
50/60 Hz
Functions
Thermal-magnetic Manual Motor Starter (MMS) / Branch protector
Design
low magnetic-trip threshold (below 15 x Ie)
Poles
3-poles (3P)
Rated current
30A...40A current setting range
40A (conventional thermal current; Ith)

Matched backup fuse ratings
125A (Class aM fuse at 400Vac)
63A (Class aM fuse at 690Vac)
160A (Class gl/gG fuse at 400Vac)
80A (Class gl/gG fuse at 690Vac)
Frame current rating
80 AF
Rated active power (kW)
11kW (AC-3; 230/240Vac)
18.5kW (AC-3; 400/415Vac)
22kW (AC-3; 500Vac)
37kW (AC-3; 690Vac)
Rated power (HP)
3HP (110-120Vac; single-phase; UL)
10HP (200Vac; 3-phase; UL)
10HP (208Vac; 3-phase; UL)
25HP (460-480Vac; 3-phase; UL)
30HP (575-600Vac; 3-phase; UL)
Rated operating voltage (Ue)
(AC) 230/240 V
(AC) 400/415 V
(AC) 460/480 V
(AC) 575/600 V
Rated impulse voltage (Uimp)
6 kV
Rated insulation voltage (Ui)
(IEC) 690 V
(UL/CSA) 600 V
Connection type
M8 HEX head screw connections
Short circuit breaking rating
42kA (type E; 240Vac; 480Y/277Vac)
18kA (type E; 600Y/347Vac)
Ultimate short circuit current breaking capacity (Icu)
50kA (400Vac)
8kA (690Vac)
Service short circuit current breaking capacity (Ics)
50kA (400Vac)
8kA (690Vac)
Trip unit type
Technology = Thermal-Magnetic (adjustable)
Protection functions
Adjustable thermal protection (Overload) Class 10
Fixed threshold magnetic protection (Short-circuit)
Phase failure protection
Protection settings
Protection against thermal overload -- 30A...40A (adjustable)
Magnetic instantaneous protection against short-circuit -- 560A
Operating mode
Rotary handle operation
Degree of protection
IP20
Dimensions
H5.51" x W2.17" x D5.39"
H140mm x W55mm x D136.8mm
Ambient air temperature for operation
-4...+140°F / -20...+60 °C
Ambient air temperature for storage
-4...+176°F / -40...+80 °C
Technical compatibility with
Ex9S80 mtr. starter
Minimum current
30 A
Maximum current
40 A
Order code / Manufacturer SKU
Ex9S80A40AM
1600188
Manufacturer product status
Commercialized
Equivalent to
1600188
Compliant with standard(s)
Vibration resistance - 5-150Hz with 5gn
Shock resistance - 30gn for 11ms
UL 60947-4-1
UL 60947-1
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
IEC/EN 60947-5-1
RoHS
CCC
NOM
CSA 22.2 No. 60947-1
CSA 22.2 No. 60947-4-1
GB/T 14048.1
GB/T 14048.2
GB/T 14048.4
Class 10
Operating rate
max. 30 Cycles/hour
Tightening torque
6 N.m
Degree of pollution
III
Application type
2000m / 6562ft max. operating altitude

Benefits

Benefits
Ex9S Manual Motor Starter provide manual isolation‚ manual motor control‚ and over-current protection.
Ex9S Manual Motor Starters are electro-mechanical devices combining the functions below in one unit.

- Disconnect for Motor Branch Circuit
- Manual Motor Control (automatic when used with contactor)
- Branch-Circuit Short Circuit Protection (Magnetic Protection)
- Overload Protection (Thermal Protection) - Trip Class 10
- 5-year limited warranty

The National Electrical Codes requires an individual Motor Branch Circuit to be protected by a UL/CSA Listed Fuse‚ Circuit breaker or Self-Protected Combination Motor Controller.

Available asː
- Up to 80A at 600Vac
- UL 60947-4-1 Type E Self Protection-Ex9S32 and Ex9S80
- UL 60947-4-1 Type F Group Motor Protection-Ex9S80
- Built-in fault indication
- Full range of accessories
- Lockable handle