DRAF12-14U

Enclosed Direct-On-Line Motor Starter (250-500V 50/60Hz)

$169.02
Factory New

ABB, Enclosed Direct-On-Line Motor Starter, Featuring an AF contactor, Safely controls 3-phase asynchronous motors up to 690V AC inside a rugged IP66 and Type 4X plastic enclosure

Representative image shown
Product Details
SKU:
DRAF12-14U
UPC:
3471522145246
Weight:
1.81 LBS
Width:
4.21 in
Height:
9.06 in
Depth:
5.16 in
Number of Poles:
3 Poles
Maximum Voltage:
690 V AC
Terminal Type:
Screw Terminals

Description

Description

The DRAF12-14U is an enclosed Direct-On-Line starter with an AF contactor used for controlling 3-phase asynchronous motors up to 690 V AC. Each starter is delivered assembled and wired.

It contains:

• IP66 and type 4X plastic enclosure with double insulation, equipped with: - 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button - 4 cable inlets and outlets via knockouts: Inch cable inlet/outlet suitable for UL starter types.

• 1 AF12-30-10-14 3-pole contactor with holding contact

• DRAF..U with separate supply for UL starters type: AC control supply: 250-500V50/60HZ

• 1 CB5-10 start contact block

• 1 PE and 1 neutral terminal

• TF42 thermal overload relay to be ordered separately and chosen according to motor's nominal current.

Specifications

Specifications

Technical

 
Coil Consumption: Holding at Max. Rated Control Circuit Voltage 60 Hz 250 V·A
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Housing Material: ABS
Number of Auxiliary Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Main Contacts NC: 0
Number of Main Contacts NO: 3
Number of Poles: 3P
Pollution Degree: 3
Rated Control Circuit Voltage (Uc):
50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 28 A
(690 V) 60 °C 28 A
(690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Power AC-3 (Pe):
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe):
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Terminal Type: Screw Terminals

Technical UL/CSA

 
Connecting Capacity Auxiliary Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Main Circuit UL/CSA:
Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Horsepower Rating NEMA:
(115 V AC) Single Phase 1 Hp
(200 V AC) Three Phase 3 Hp
(230 V AC) Single Phase 2 Hp
(230 V AC) Three Phase 3 Hp
(460 V AC) Three Phase 5 Hp
(575 V AC) Three Phase 5 Hp
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 1 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Pilot Duty UL/CSA:
A600
Q600