Product Details
SKU:
SCE-AC21160B460V3
Weight:
188.00 LBS
Width:
18.00 in
Height:
44.70 in
Depth:
15.40 in
Dimensions:
44.7in x 18in x 15.4in

Construction

Construction

SCE-AC21160B460V3 Saginaw Control & Engineering 44.7 x 18 x 15.4 Air Conditioner 21160 BTU 460V 3 Phase

  • Heavy gauge steel/stainless steel.
  • Internal components are corrosion resistant.
  • Coils are designed as filterless units, fin spacing and hydrophobic Nano coating to help reduce chance of clogging.
  • Washable, Reusable 8 layer aluminum mesh filters included.
  • Captive screw fastened filter cover.
  • Compressor Heater
  • Enclosure Heater for low ambient temperatures.
  • Easy Mounting Flange hangers for installation included.
  • High temp alarm
  • High performance ball bearing fans.
  • Door activated switch wiring provisions.
  • Cage clamp terminal connector.
  • Oil and water resistant gaskets installed.

Application

Application

SCE-AC21160B460V3 Saginaw Control & Engineering 44.7 x 18 x 15.4 Air Conditioner 21160 BTU 460V 3 Phase

Enviro-Therm® Air Conditioners are designed
with an internal closed loop system to
provide protection from dust, oil and
water. For indoor and outdoor application.
Rugged, energy efficient, and reliable cooling
system.

Finish

Finish

SCE-AC21160B460V3 Saginaw Control & Engineering 44.7 x 18 x 15.4 Air Conditioner 21160 BTU 460V 3 Phase

Powder coated steel cover RAL 7035 River
Texture over Aluzinc coated steel.

 

Industry Standards

Industry Standards

SCE-AC21160B460V3 Saginaw Control & Engineering 44.7 x 18 x 15.4 Air Conditioner 21160 BTU 460V 3 Phase

  • NEMA Type 3R, 4 & 12
  • UL Recognized Type 3R, 4 & 12
  • IEC 60529
  • IP 56

 

NEMA Rating for

Nema active
N1
Indoor
Protection from fingers, tools and small objects
Nema active
N12
Indoor
Protection from dust and light splashes of water
Nema active
N3R
Outdoor
Protection from rain, snow and sleet
Nema active
N4
Outdoor
Protection from rain, snow, sleet, and hose directed water
Nema not active
N4X
Outdoor
Protected from rain, snow, sleet, and pressure rated hose directed water from all angles
N1 graphic N12 graphic N3R graphic N4 graphic N4X graphic
+
Environments Type 1 Type 12 Type 3R Type 4 Type 4X
Indoor use only
Indoor and outdoor use
Falling liquids and light splashes
Nonhazardous dust, lint, and fibers
Washdowns and splashing water
Oil and coolant seepage
Corrosive agents
Hazardous locations
(Class I, Division 1 and 2)