Representative image shown

SCE-36XEL3116LP

XEL LP Enclosure

$702.02
Representative image shown
Product Details
SKU:
SCE-36XEL3116LP
Weight:
113.00 LBS
Dimensions:
36in x 31.38in x 16in

Construction

Construction

SCE-36XEL3116LP Saginaw Control & Engineering 36 x 31.38 x 16 XEL LP Enclosure

  • 0.075 In. carbon steel.
  • Seams continuously welded and ground smooth.
  • Flange trough collar around all sides of door opening.
  • Pour in place oil & water resistant gasket
  • Collar studs 3/8-16 provided for mounting optional panels.
  • Disconnect cutout provided on flange.
  • Concealed hinges.
  • Doors are interchangeable and easily removed by pulling hinge pins.
  • 3-point latching mechanism when door height is greater or equal to 40 inches, 2-point latching mechanism when door height is less than 40 inches.
  • Latches are opened or closed with a screwdriver (optional tamper-resistant inserts are available).
  • Mounting holes on back of enclosure.
  • Mounting hardware, sealing washer and hole plug included.
  • Ground studs on door and body.
  • Black zinc die cast coinproof/padlocking handle.
  • Removable print pocket.

Application

Application

SCE-36XEL3116LP Saginaw Control & Engineering 36 x 31.38 x 16 XEL LP Enclosure

Designed to house electrical and electronic controls, instruments and components. Provides protection from dust, oil and water. Designed to house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended.

Finish

Finish

SCE-36XEL3116LP Saginaw Control & Engineering 36 x 31.38 x 16 XEL LP Enclosure

ANSI-61 gray powder coating inside and out. Optional sub-panels are powder coated white.

 

Industry Standards

Industry Standards

SCE-36XEL3116LP Saginaw Control & Engineering 36 x 31.38 x 16 XEL LP Enclosure

  • NEMA Type 3R, 4, 12 and Type 13
  • UL Listed Type 3R, 4 and 12
  • CSA Type 3R, 4 and 12
  • IEC 60529
  • IP 66

NEMA Rating for

Nema active
N1
Indoor
Protection from fingers, tools and small objects
Nema active
N12
Indoor
Protection from dust and light splashes of water
Nema active
N3R
Outdoor
Protection from rain, snow and sleet
Nema active
N4
Outdoor
Protection from rain, snow, sleet, and hose directed water
Nema not active
N4X
Outdoor
Protected from rain, snow, sleet, and pressure rated hose directed water from all angles
N1 graphic N12 graphic N3R graphic N4 graphic N4X graphic
+
Environments Type 1 Type 12 Type 3R Type 4 Type 4X
Indoor use only
Indoor and outdoor use
Falling liquids and light splashes
Nonhazardous dust, lint, and fibers
Washdowns and splashing water
Oil and coolant seepage
Corrosive agents
Hazardous locations
(Class I, Division 1 and 2)