Representative image shown

SCE-100AFSD

Arc Flash Enclosure

$218.29
Representative image shown
Product Details
SKU:
SCE-100AFSD
Weight:
17.00 LBS
Dimensions:
22in x 12in x 6.5in

Construction

Construction

SCE-100AFSD Saginaw Control & Engineering 22 x 12 x 6.5 Arc Flash Enclosure

  • 0.060 In. carbon steel.
  • Enclosures are symmetrical for use with left or right hand disconnects.
  • Removable continuous hinges.
  • 110 degree door stop prevents incidental contact with other components.
  • Black quarter turn latch.
  • Black spring loaded quarter turn latch with 7mm square insert and key.
  • Latches automatically when door is closed.
  • Gland plate top and bottom provides easy installation of wires.
  • Mounting holes provided in back for securing to the sub-panel of main enclosure.
  • Ground stud on door and body.

Application

Application

SCE-100AFSD Saginaw Control & Engineering 22 x 12 x 6.5 Arc Flash Enclosure

Designed for use with enclosures that require additional protection against Arc Flash. This enclosure can be used within an environmentally rated enclosure to isolate the main power supply. Increasing personal protection by preventing incidental contact or exposure to the high voltage arc flash and shock hazard, and potentially reducing the PPE level for the lower risk components when the Internal Disconnect Enclosure cover is closed.
The Internal Disconnect Enclosure can be easily incorporated into a new system or added to a pre-existing system on variable depth or cable operated disconnects. Aids in achieving compliance with NFPA 70E by concealing main power supply.

Finish

Finish

SCE-100AFSD Saginaw Control & Engineering 22 x 12 x 6.5 Arc Flash Enclosure

Orange texture powder coat.

 

Industry Standards

Industry Standards

SCE-100AFSD Saginaw Control & Engineering 22 x 12 x 6.5 Arc Flash Enclosure

  • NEMA Type 1
  • UL Listed Type 1
  • CSA Type 1
  • IEC 60529
  • IP 30

NEMA Rating for

Nema active
N1
Indoor
Protection from fingers, tools and small objects
Nema not active
N12
Indoor
Protection from dust and light splashes of water
Nema not active
N3R
Outdoor
Protection from rain, snow and sleet
Nema not active
N4
Outdoor
Protection from rain, snow, sleet, and hose directed water
Nema not active
N4X
Outdoor
Protected from rain, snow, sleet, and pressure rated hose directed water from all angles
N1 graphic N12 graphic N3R graphic N4 graphic N4X graphic
+
Environments Type 1 Type 12 Type 3R Type 4 Type 4X
Indoor use only
Indoor and outdoor use
Falling liquids and light splashes
Nonhazardous dust, lint, and fibers
Washdowns and splashing water
Oil and coolant seepage
Corrosive agents
Hazardous locations
(Class I, Division 1 and 2)