- 30–1200A
- 600 Vac, 600 Vdc maximum
- Horsepower rated
- Fusible and non-fusible switches are 100% load break and 100% load make rated
- The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated
- Suitable for service entrance applications unless otherwise noted
NEMA Rating
Features
DH367NRK Eaton Heavy Duty Single-Throw Fused Safety Switch (800A, 3P, 600V, NEMA 3R)
- Deionizing arc chutes; arc chutes confine and suppress the arcs produced by opening contacts under load
- Mechanically interlocked cover to prevent easy access when the switch is in the ON position
- Clearly visible palm fitting red handle
- Premium 316-Grade stainless steel enclosures offer better corrosion resistance in the presence of most chemicals, salts and acids, and is more resistant to marine atmospheres
- Visible double-break quick-make, quick-break blades
- Visible ON/OFF indication
- 30–1200A NEMA 12 designs convertible to NEMA 3R by opening factory-installed drain hole
- Tri-lingual nameplates
Visible Double-Break Rotary Blade Mechanism
- Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life
Clear Line Shield
- Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not typically provided on general-duty switches, but available as a field kit or factory installed
Built-In Fuse Pullers (NEMA 12 and 4X 30–200A Only)
- Provide easy removal of fuses
Clearly Visible Handle
The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation
Triple Padlocking Capability
- Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks
Additional Locking Capability
- Cabinet door can be further padlocked at the top and bottom as applicable
Interlocking Mechanism
- Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single-throw switches
Tangential Knockouts
- An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A
Bolt-On Hub Kits
- For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others
Specifications
DH367NRK Eaton Heavy Duty Single-Throw Fused Safety Switch (800A, 3P, 600V, NEMA 3R)
Product Name |
Eaton heavy duty fusible safety switch
|
---|---|
Catalog Number | DH367NRK |
UPC | 782113639277 |
Product Length/Depth |
57.5 in
|
Product Height | 12.38 in |
Product Width | 27.5 in |
Product Weight | 210 lb |
Warranty |
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
|
Certifications | UL Listed |
Enclosure |
NEMA 3R
|
Enclosure Material | Painted galvanized steel |
Fuse Class Provision |
Class L
|
Fuse Configuration | Fusible with neutral |
Number of Poles |
Three-pole
|
Number of Wires | 4 |
Type | Heavy duty fusible safety switch |
Amperage Rating | 800A |
HP Rating - Max |
500, 500 hp (3PH @480/600 V)
|
NEMA Rating | NEMA 3R |
Voltage Rating | 600 V |
Product Category | Heavy Duty, Fusible with neutral |
Warranty Information
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.