Specifications - ABB PSTX840-600-70
Product Net Width | 435 mm |
---|---|
Product Net Height | 493 mm |
Product Net Depth / Length | 369 mm |
Product Net Weight | 46.5 kg |
Rated Operational Voltage | 208 ... 690 V AC |
Rated Control Supply Voltage (Us) | 100 ... 250 V AC |
Rated Control Circuit Voltage (Uc) | 24 V DC |
Rated Frequency (f) | 50/60 Hz Main Circuit 50 / 60 Hz |
Rated Operational Power - In-Line Connection (Pe) | (230 V) 250 kW (400 V) 450 kW (500 V) 600 kW (690 V) 800 kW |
Rated Operational Current - In-Line Connection (Ie) | 840 A |
Rated Operational Power - Inside Delta Connection | at 230 V 450 kW at 400 V 800 kW at 500 V 1000 kW at 690 V 1400 kW |
Rated Operational Current - Inside Delta Connection | 1455 A |
Service Factor Percentage | 100 % |
Overload Protection | Built-in electronic overload protection |
Integrated Electronic Overload | Yes |
Adjustable Rated Motor Current Ie | 30 ... 100 % |
Starting Capacity at Maximum Rated Current Ie | 4xIe for 10s |
Ramp Time | 1 ... 120 second [unit of time] |
Initial Voltage During Start | 10 ... 99 % |
Step Down Voltage Special Ramp | 100 ... 10 % |
Current Limit Function | 1.5 ... 7.5 xle |
Switch for Inside Delta Connection | Yes |
Run Signal Relay | Yes |
By-pass Signal Relay | Yes |
Fault Signal Relay | Yes |
Overload Signal Relay | Yes |
Analog Outputs | 0…10 V, 0…20 mA, 4…20 mA |
Signal Indication Ready to Start/Standby ON (LED) | Green |
Signal Indication Running R (LED) | Green |
Signal Indication Protection (LED) | Yellow |
Signal Indication Fault (LED) | Red |
Communication | Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP |
Degree of Protection | IP00 |
Terminal Type | Main Circuit: Bars |
Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm² |
Connecting Capacity Supply Circuit | Rigid 1 x 2.5 mm² |
Tightening Torque | Main Circuit 45 N·m |
Product Main Type | PSTX840 |
Function | Auto phase sequence detection Automatic restart Current limit Current limit ramp Dual current limit Dynamic brake Electricity metering Electronic overload Time-to-cool Emergency mode Event log Full voltage start Jog with slow speed, forward and reverse Keypad password Kick start Limp mode with two-phase motor control if one set of thyristors is shorted Motor heating Pre-start function Pump cleaning Real time clock Sequence start Soft start with torque control Soft start with voltage ramp Soft stop with torque control Soft stop with voltage ramp Stand still brake Start reverse (external contactors) Thyristor runtime measurement Torque limit Voltage sags detection |
Protection Function | Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection |
Warning Details | Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning |