S811+U50N3S

Soft Starter (500 Amps)
Representative image shown

$17,092.39
$21,684.37
Product Condition: New

Eaton S811+ soft starter, Frame U, 500 A, 400 hp, 480 V, # 4 AWG to 500 kcmil, 156-500 FLA, 24 Vdc, 200-600 V operating, 1-2 conductors, LCD, HLD circuit breaker, Class RK5/J Fuse

SKU:
S811+U50N3S
UPC:
786685879581
Weight:
41.00 LBS
Width:
14.50 in
Height:
12.50 in
Depth:
19.00 in
Series:
S811+
Amperage:
500 Amps
Frame Size:
U

S811+ Soft Starter Features

The Eaton S811+/S801+ soft starter family delivers solid performance beyond standard protection features found in most soft starters. Choosing a soft starter will increase your productivity and reduce your costs by:

  • Eliminating abrupt starts and stops, extending mechanical life of system
  • Better control of motor torque, increasing gearbox and bearing life, reducing belt wear and eliminating water hammer
  • Lowering inrush, reducing peak demand charges
  • Reducing brownouts and decreasing overall energy usage
  • Integrating overload protection
  • Reducing number of devices, panel size, installation time and assembly costs with internal run bypass contactors

Compact, easy to program and easy to install, the S811+ line of soft starters is ideally suited for open, enclosed and motor control center (MCC) applications. Ranging from 11 A to 1000 A, the S811+ provides an array of built-in features designed to address the needs of industrial and OEM customers.

  • Sophisticated pump algorithm
  • Communication ready—native Modbus® RTU and QCPort with external EtherNet/IP and Modbus TCP communication modules
  • Advanced protection capabilities
  • Sophisticated monitoring functions: power, power factor, phase currents, phase voltage, device temperature and more
  • Selectable warnings available to avoid nuisance tripping
  • Streamlined menu structure for programming, easy installation, setup, maintenance and monitoring
  • Copy-and-paste keypad user interface
  • Pump and 690 V versions (P3S and V3S) include ground fault protection

S811+ Soft Starter Benefits

Smaller Size

The S811+/S801+ units are among the smallest starters in the industry. Reducing enclosure size for new production units, and enabling easier retrofits, minimizes the system costs

Severe Duty Capable

The S811+/S801+ soft starters have been time tested in various applications and environments. This family features conformally coated boards suitable for harsh environments. Kick-start function enables soft starting of high inertia loads.

Integrated Advanced Intelligence

High levels of protection are built into the S811+/S801+ soft starters.

  • Protective features: electronic overload, jam, stall, SCR over-temperature, phase loss, phase imbalance, automatic or manual reset, phase reversal, shorted SCR detection, open SCR detection, undercurrent, under-voltage, over-voltage, diagnostics

Packaged Options

Packaged S811+/S801+ units give you more starting torque and more motor current in dramatically reduced enclosures. Enclosed soft starter units are up to 78 percent smaller, and MCC units are up to 63 percent smaller, than competitive offerings.

S811+ Soft Starter Specifications

Product Length/Depth 19 in
Product Height 12.5 in
Product Width  14.5 in
Product Weight 45 lb
Certifications EN 60947-4-2
UL Listed
CSA file No. 3211-06
CSA file No. 2411-01
Phase Three-phase
AC Current - Max 240 Vac
DC Current - Max 120 Vdc
Wire Size #4 AWG-500 kcmil
Operating Temperature - Min -30 °C 
Power Supply 24 V 
Size NEMA 0
Amperage Rating 500A
Number of Poles Three-pole
Display Material LCD
Frame Size U
Type Soft starter
Operating Voltage 200-600 V
Used With Three-phase motors
Operating Temperature - Max 50 °C
Nema Rating NEMA 0
Frequency Rating 47-63 Hz
Module Interface Digital interface module
Communication Modbus RTU
 Initial torque 0–85%
Ramp time range  0.5–180 seconds
Soft stop time range 0–60 seconds
Kick-start time rang 0–2 seconds
Vibration resistance—non-operating 3 g
Vibration resistance—operating 3 g
Shock resistance  15 g 
Operating voltage 200–600 V (T-, V-Frame—up to 690 V)
Overload setting (frame) 30–100% FLA
Trip class 5, 10, 20, 30
Voltage range (24 V ±10%)  21.6–26.4 V
Steady-state current  1 A
In-rush current 10 A
Voltage AC—maximum  230 V
Voltage DC—maximum  24 V
Amperes—maximum  3 A
Temperature—operating  –30 °C to +50 °C
Temperature—storage  –50 °C to +70 °C
Altitude <2000 m
Humidity  <95% noncondensing
Operating position  Any
Pollution degree IEC947-1  3
Impulse withstand voltage IEC947-4-1  6000 V
Show MoreLess