FP65U2343ABA

AC Variable Frequency Drive (125 HP, 343 Amps, 240V, 3-Phase, IP20/Protected Chassis)
Representative image shown
Product Condition: New
SKU:
FP65U2343ABA
Weight:
240.30 LBS
Width:
17.30 in
Height:
31.50 in
Depth:
18.60 in
Normal Duty Output (HP) (VT):
125 HP
Rated Output Current (Amps) (VT):
343 Amps

The FP605 was built on three aspects; Flexibility, Sustainability, and Ease of Use. The FP605 is flexible by providing a drive solution for every environment, the ability to run any motor type, hardware and network control solutions, and a simple to install design. The FP605 is sustainable through its integrated functional safety capability, environmentally friendly materials, and as always Yaskawa’s durable and long lasting quality and design. The FP605 is easy through its use of in-box media. Its simple installation and startup is achieved using its intuitive keypad and software tools.

Features

The FP605 is a flexible, sustainable, easy-to-use industrial fan and pump drive.

Drives for Every Environment
  • IP20/UL Type 1
  • IP55/UL Type 12
  • IP55/Type 12 with Switch
  • IP20/Protected Chassis
  • IP55/UL Type 12 Backside
Flexible Solution
  • -10°C to +60°C ambient*
  • Side-by-side mounting*
  • UL Type 1 End cap kits for IP20/Protected Chassis drives
  • External heatsink mounting (UL Type 1 and UL Type 12)
  • Compatible with all major network communication protocols
Sustainable
  • 10-year maintenance-free operation
  • Compliance with global certifications and standards
  • Built-in (5% split or 3% positive bus DC link choke) line impedance for harmonic reduction
  • Embedded STO functional safety maximizes production uptime
  • Conformal coating for circuit board protection
Quick and Easy Set-Up
  • Simple steps for efficient commissioning
  • Convenient programming without main power
  • Operates induction, permanent magnet, and synchronous reluctance motors
  • DriveWizard® Mobile app for drive management on smart mobile devices
Simple Operation
  • High visibility status ring
  • 32-character keypad with LCD display and tactile buttons
  • Compatible with all major network communication protocols
Advanced Pump Control
  • Fast and easy pump setup
  • Easy-to-understand pump terminology
  • Application presets for faster commissioning
  • Advanced pump protection features
  • Contactor multiplexing for pump systems

Specifications

Input Voltage Three-phase 200 to 240V AC, 380 to 480V AC, +10%/-15%, 50/60 Hz +/-5%
Ambient Operating Temperature -10 to +50°C (IP20/Protected Chassis)
-10 to +40°C (IP20/UL Type 1)
-10 to +40C (IP55/UL Type 12)
Up to +60°C (with derate)
Ambient Storage -20°C to +70°C (-4°F to 158°F)
Overload Capacity 110% for 60 sec.
140% for 2 sec.
175% instantaneous
Output Frequency up to 400 Hz
Control Methods Open Loop V/f
Open Loop Vector (PM motors only)
EZ Open Loop Vector
Motor Types Induction
Permanent Magnet
Synchronous Reluctance
Environmental 1,000 meters altitude, up to 4,000 meters with derating
Class 3C2 and 3S2 operation for IP20/UL Type 1 & IP20/Protected Chassis
Class 3C2 and 3S3 for IP55/UL Type 12
95% humidity, non-condensing
Harmonics 5% split choke built in both positive and negative DC bus leg as standard
(3% DC link on positive bus for IP20/Protective Chassis designs)
Protective Design Types IP20/UL Type 1
IP55/UL Type 12
IP20/Protected Chassis
Global Certifications UL, cUL, CE, RoHS 2, WEEE, TUV SUD
Seismic Certification IBC
HCAI (Special Seismic Certification Preapproval OSP-0687)
Functional Safety Safe Torque Off, SIL3 according to IEC 62061, PLe according to ISO 13849-1
Interface LCD keypad and Status Ring, Bluetooth® is optional
Standard I/O (8) multi-function digital inputs (+24 VDC)
(3) multi-function analog inputs (0 +/- 10 VDC, 4-20 mA)
(1) multi-function pulse inputs
(2) Safe Torque Off inputs
(2) fault relay output (form C)
(2) multi-function relay outputs (form A)
(2) multi-function analog output (0 +/- 10 VDC, 4-20mA)
+24 VDC Input External supply input to maintain communications without main power
150 mA output for customer use
I/O Expansion (3) Analog Inputs -10 to +10V, 13 bit plus sign, 4 to 20mA
(16) Digital Inputs
(2) Analog Outputs (-10 to +10V, 11 bit magnitude)
(8) Digital Outputs (6 transistor, 2 relay)
Network Communication Standard: Modbus RTU, RS-485, 115 kbps
Optional: EtherNet/IP™, DeviceNet, Modbus® TCP/IP, PROFINET, PROFIBUS-DP
Software Support Tools DriveWizard® Industrial
DriveWizard® Mobile
Programming Simulator
Energy Savings Predictor
Harmonics Estimator
Product Selector

Videos

Related Products

GA80U2360ABM Yaskawa AC Variable Frequency Drive (150 HP, 360 Amps VT - 125 HP, 346 Amps CT, 240V, 3-Phase, IP20/Protected Chassis)

GA80U2360ABM

AC Variable Frequency Drive (150 HP, 360 Amps VT - 125 HP, 346 Amps CT, 240V, 3-Phase, IP20/Protected Chassis)
GA80U2313ABM Yaskawa AC Variable Frequency Drive (125 HP, 313 Amps VT - 100 HP, 283 Amps CT, 240V, 3-Phase, IP20/Protected Chassis)

GA80U2313ABM

AC Variable Frequency Drive (125 HP, 313 Amps VT - 100 HP, 283 Amps CT, 240V, 3-Phase, IP20/Protected Chassis)