Overload Relays

Protect your motors from overcurrent and overheating with ABB overload relays. Available in thermal and electronic options, our relays provide reliable motor protection for a variety of applications, including pumps, conveyors, and HVAC systems. Ensure your operations run smoothly and safely with the right motor protection solution from Wistex.

Need assistance selecting the right overload relay? Contact our team.

  • Ex9R100B70A Noark  Thermal Overload Relay, Ex9R, 100 A, Use with Ex9C40-100, Trip Class 10, 55~70 A

    Ex9R100B70A

    $74.01
    $82.23
    Thermal Overload Relay, Ex9R, 100 A, Use with Ex9C40-100, Trip Class 10, 55~70 A
  • Ex9R100B80A Noark  Thermal Overload Relay, Ex9R, 100 A, Use with Ex9C40-100, Trip Class 10, 63~80 A

    Ex9R100B80A

    $74.01
    $82.23
    Thermal Overload Relay, Ex9R, 100 A, Use with Ex9C40-100, Trip Class 10, 63~80 A
  • Ex9R12B0.16A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.1~0.16 A

    Ex9R12B0.16A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.1~0.16 A
  • Ex9R12B0.25A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.16~0.25 A

    Ex9R12B0.25A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.16~0.25 A
  • Ex9R12B0.4A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.25~0.4 A

    Ex9R12B0.4A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.25~0.4 A
  • Ex9R12B0.63A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.4~0.63 A

    Ex9R12B0.63A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.4~0.63 A
  • Ex9R12B1.6A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 1~1.6 A

    Ex9R12B1.6A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 1~1.6 A
  • Ex9R12B10A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 7~10 A

    Ex9R12B10A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 7~10 A
  • Ex9R12B12A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 9~12 A

    Ex9R12B12A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 9~12 A
  • Ex9R12B1A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.63~1 A

    Ex9R12B1A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 0.63~1 A
  • Ex9R12B2.5A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 1.6~2.5 A

    Ex9R12B2.5A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 1.6~2.5 A
  • Ex9R12B4A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 2.5~4 A

    Ex9R12B4A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 2.5~4 A
  • Ex9R12B6A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 2.5~4 A

    Ex9R12B6A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 2.5~4 A
  • Ex9R12B8A Noark  Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 5.5~8 A

    Ex9R12B8A

    $26.24
    $29.16
    Thermal Overload Relay, Ex9R, 12A, Use with Ex9CS06-12, Trip Class 10, 5.5~8 A
  • Ex9R185B115A Noark  Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 75~115 A

    Ex9R185B115A

    $227.62
    $252.91
    Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 75~115 A
  • Ex9R185B150A Noark  Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 110~150 A

    Ex9R185B150A

    $227.62
    $252.91
    Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 110~150 A
  • Ex9R185B210A Noark  Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 140~210 A

    Ex9R185B210A

    $227.62
    $252.91
    Thermal Overload Relay, Ex9R, 185 A, Use with Ex9C115-185, Trip Class 10, 140~210 A
  • Ex9R38B1.6A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 1~1.6 A

    Ex9R38B1.6A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 1~1.6 A
  • Ex9R38B10A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 7~10 A

    Ex9R38B10A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 7~10 A
  • Ex9R38B13A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 9~13 A

    Ex9R38B13A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 9~13 A
  • Ex9R38B18A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 12~18 A

    Ex9R38B18A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 12~18 A
  • Ex9R38B1A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 0.63~1 A

    Ex9R38B1A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 0.63~1 A
  • Ex9R38B2.5A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 1.6~2.5 A

    Ex9R38B2.5A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 1.6~2.5 A
  • Ex9R38B24A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 16~24 A

    Ex9R38B24A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 16~24 A
  • Ex9R38B32A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 23~32 A

    Ex9R38B32A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 23~32 A
  • Ex9R38B38A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 30~38 A

    Ex9R38B38A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 30~38 A
  • Ex9R38B4A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 2.5~4 A

    Ex9R38B4A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 2.5~4 A
  • Ex9R38B6A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 4~6 A

    Ex9R38B6A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 4~6 A
  • Ex9R38B8A Noark  Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 5.5~8 A

    Ex9R38B8A

    $51.44
    $57.15
    Thermal Overload Relay, Ex9R, 38 A, Use with Ex9C09-38, Trip Class 10, 5.5~8 A
  • Ex9R500B225A Noark  Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 160~225 A

    Ex9R500B225A

    $697.33
    $774.81
    Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 160~225 A
  • Ex9R500B300A Noark  Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 210~300 A

    Ex9R500B300A

    $697.33
    $774.81
    Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 210~300 A
  • Ex9R500B400A Noark  Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 280~400 A

    Ex9R500B400A

    $697.33
    $774.81
    Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 280~400 A
  • Ex9R500B500A Noark  Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 380~500 A

    Ex9R500B500A

    $697.33
    $774.81
    Thermal Overload Relay, Ex9R, 500 A, Use with Ex9C225-500, Trip Class 10, 380~500 A
  • Ex9RE40A0.5 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 24Vac/dc

    Ex9RE40A0.5

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 24Vac/dc
  • Ex9RE40A02 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 24Vac/dc

    Ex9RE40A02

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 24Vac/dc
  • Ex9RE40A09 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 24Vac/dc

    Ex9RE40A09

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 24Vac/dc
  • Ex9RE40A40 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 24Vac/dc

    Ex9RE40A40

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 24Vac/dc
  • Ex9RE40B0.5 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 110/120Vac

    Ex9RE40B0.5

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 110/120Vac
  • Ex9RE40B02 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 110/120Vac

    Ex9RE40B02

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 110/120Vac
  • Ex9RE40B09 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 110/120Vac

    Ex9RE40B09

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 110/120Vac
  • Ex9RE40B40 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 110/120Vac

    Ex9RE40B40

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 110/120Vac
  • Ex9RE40C0.5 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 220/240Vac

    Ex9RE40C0.5

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.1-0.5A, control voltage: 220/240Vac
  • Ex9RE40C02 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 220/240Vac

    Ex9RE40C02

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:0.4-2A, control voltage: 220/240Vac
  • Ex9RE40C09 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 220/240Vac

    Ex9RE40C09

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:1.8-9A, control voltage: 220/240Vac
  • Ex9RE40C40 Noark Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 220/240Vac

    Ex9RE40C40

    $157.46
    $174.96
    Ex9R Electronic Over-Load Relay, Class 5/10/20/30, Frame 40A, Setting Amp:8-40A, control voltage: 220/240Vac
  • LT200E | ABB Terminal Shroud For E200Du

    LT200E

    $44.22
    $70.14
    Terminal Shroud For E200Du
  • LT320E | ABB Terminal Cover For E320Du

    LT320E

    $44.22
    $70.14
    Terminal Cover For E320Du

Overload Relays We Offer

Wistex offers a full range of overload relays designed to protect motors from overheating, phase loss, and excessive current. Whether you need thermal or electronic protection, we provide reliable solutions for industrial applications across manufacturing, pumping, and HVAC systems.

Thermal Overload Relays

Thermal overload relays use a bimetallic strip that reacts to heat generated by excess current. As the strip bends under heat, it trips the relay to disconnect the motor, preventing damage. Thermal relays are highly effective for basic motor protection and are ideal for rugged environments where simplicity and reliability are key.

Electronic Overload Relays

Electronic overload relays use digital sensors to detect current surges with greater precision and speed. They offer adjustable settings, diagnostics, and advanced features like phase failure detection. Electronic relays are well-suited for applications requiring flexible, programmable motor protection and integration with control systems.

Applications for Overload Relays

Our overload relays are ideal for:

  • Motor protection for water pumps and industrial fans
  • Conveyor belt systems in manufacturing
  • HVAC system compressors and blower motors

Complete your motor control system with contactors and soft starters.

Why Choose Wistex for Overload Relays & Motor Protection

Protect your investments with overload relays from Wistex. Our selection of thermal and electronic overload relays from ABB provides vital protection against overcurrent, phase failure, and overheating — essential for industries like manufacturing, pumping, and HVAC.

Why choose Wistex for overload relays?

  • Specialized expertise in motor protection and system design
  • In-stock options for fast shipping when downtime isn’t an option
  • Top brands like ABB for unmatched reliability
  • Support beyond the sale — helping you with setup, replacement, and scaling needs

Keep your motors safe and your business moving forward with overload relays from Wistex.

FAQs about Overload Relays

Understand how overload relays protect your motors and improve operational reliability.

Overload relays detect excessive current flowing through a motor circuit. If the current exceeds a preset level for too long (indicating a jam, blockage, or overload), the relay trips to disconnect the motor, preventing overheating and mechanical damage.

Thermal overload relays use a mechanical bimetallic strip that bends when heated by excess current. Electronic overload relays use sensors and processors for faster, more precise detection of overload conditions, often with more flexible setting options.

Replace an overload relay if it trips frequently without valid cause, shows inconsistent operation, suffers visible damage, or if the protected motor has been upgraded to a higher horsepower. Routine inspection during maintenance can help catch early signs of failure.