MS165-42

Manual Motor Starter (3P, 42A, 600V)
Representative image shown

$310.20
$710.75
Product Condition: New
SKU:
MS165-42
Weight:
2.43 LBS
Amperage:
42 Amps
Number of Poles:
3 Pole

MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, under-voltage releases, shunt trips, power in-feed blocks are available as accessory. These
are suitable throughout the MS116/MS132/MS165 range.

Specifications

Dimensions

 
Product Net Width 55 mm
Product Net Height 142.65 mm
Product Net Depth / Length 122.1 mm

Technical

 
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 50 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 630 A
Setting Range 30 ... 42 A
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 22 kW
Rated Operational Voltage Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie) 42 A
Rated Operational Current AC-3 (Ie) 42 A
Rated Operational Current AC-3e (Ie) 42 A
Rated Operational Current DC-5 (Ie) 42 A
Rated Frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Rated Insulation Voltage (Ui) 1000 V
Power Loss at Rated Operating Conditions per Pole 2.79 ... 5.47 W
Number of Poles 3
Conventional Free-air Thermal Current (Ith) Main Circuit 42 A
Degree of Protection Housing IP20
Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 25000 cycle
Mechanical Durability 50000 cycle
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque Main Circuit 4 N·m
Wire Stripping Length Main Circuit 16 mm
Recommended Screw Driver Pozidriv 2
Mounting Position 1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position Indication ON / OFF / TRIP
Standards CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Show MoreLess