MO165-25

Magnetic Only Manual Motor Starter (3P, 600V AC, 25A)
Representative image shown

$295.96
$585.05
Product Condition: New

ABB, MO165 Series, manual motor starter magnetic only, 3 poles, 600VAC, 25 Amps, Screw terminals, rotary handle actuator type

SKU:
MO165-25
UPC:
4013614486142
Weight:
2.43 LBS
Width:
2.16 in
Height:
5.61 in
Depth:
4.80 in
Number of Poles:
3 Pole
Voltage:
600V AC
Amperage:
25 Amps

The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.

Specifications

MO165-25 ABB Magnetic Only Manual Motor Starter (3P, 600V AC, 25A)

Product Net Width 55 mm
Product Net Height 142.65 mm
Product Net Depth / Length 122.1 mm
Product Net Weight 0.96 kg
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 375 A
Setting Range None
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 11 kW
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 11 kW
Rated Operational Voltage Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie) 25 A
Rated Operational Current AC-3 (Ie) 25 A
Rated Operational Current AC-3e (Ie) 25 A
Rated Operational Current DC-5 (Ie) 25 A
Rated Frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Rated Insulation Voltage (Ui) 1000 V
Power Loss 3.63 W
Number of Poles 3
Conventional Free-air Thermal Current (Ith) Main Circuit 25 A
Degree of Protection Housing IP20
Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 25000 cycle
Mechanical Durability 50000 cycle
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque Main Circuit 4 N·m
Wire Stripping Length Main Circuit 16 mm
Recommended Screw Driver Pozidriv 2
Mounting Position 1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position Indication ON / OFF / TRIP
Standards CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Remarks For overload protection of the motors, an appropriate thermal or electronic overload relays must be used